Assessment of Novel MRI Quantification Free Breathing Technique in Evaluation of Liver Lesions

The primary objective of this study is to develop and validate simultaneous free-breathing 4D fat and water quantification and quantitative dynamic contrast enhanced perfusion in the liver. Secondary aims include developing and validating free breathing quantification of relaxation parameters T1 and T2, and developing and validating a minimal breath-hold (< 8 s) high quality diffusion exam using highly accelerated steady state diffusion imaging sequences. Investigators aim to scan 100 subjects receiving liver biopsies as a part of their standard care and another 70 subjects with known benign lesions. The study is greater than minimal risk.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–100 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

University Hospitals Cleveland Medical Center, Case Comprehensive Cancer Center

Cleveland, Ohio, 44106, United States

About this study

The investigators hypothesize that a quantitative and near free-breathing MRI approach with Hepatocellular carcinoma (HCC) patients will lead to improved tissue characterization, resulting in fewer ambiguous readings and thus fewer biopsies. As each component of the proposed methodology has been experimentally validated in the investigators preliminary work, the next appropriate step would be to evaluate the clinical feasibility of the exam. The investigators goal is to test the ability of quantitative MRI techniques to provide high quality images of the liver and to differentiate liver lesions from one another in a time frame shorter than a current clinical exam.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • No contraindications to getting contrast enhanced MRI examinations.
  • GFR ≥ 40.

Exclusion criteria

  • Patients with ferromagnetic or otherwise non-MRI compatible aneurysm clips.
  • The presence of an implanted pacemaker or implanted defibrillator device
  • Patients with contraindications for MRI due to embedded foreign metallic objects. Bullets, shrapnel, metalwork fragments, or other metallic material adds unnecessary risk to the patient.
  • Pregnancy. Regular clinical practice already excludes pregnant patients from gadolinium contrast due to unknown effects on the fetus. The current clinical practice will be applied - patients will be verbally screened and asked if they think they could be pregnant. If the answer is yes, then the patient will be excluded from the study. If the patient is uncertain about the pregnancy status, she will be given an option to undergo a pregnancy test or not participate in the study altogether. Patients who self report that they are not pregnant will be allowed to participate in the study. This procedure is based on current department policy guidelines.
  • Implanted medical device not described above that is not MRI-compatible;
  • Known history of claustrophobia;
  • Known history of allergic reaction to Magnetic Resonance contrast material;
  • Late stage renal failure with estimated glomerular filtration rate (eGFR) of less than 30 mL/min/1.73 m2 based on patient's serum creatinine due to the significantly increased risk of nephrogenic systemic fibrosis (NSF). ('Past' 3 months timeframe will be used to calculate the eGRF).
  • Minors will be excluded.
  • Prisoners and members of other vulnerable populations will be excluded from this study. The subject selection population will not regularly include prisoners and other vulnerable population members as these populations will not provide any additional unique information to or uniquely benefit from the study. Non-english speaking population will be excluded from the study due to lack of sufficient resources to pay for translator and interpreter services.

Treatment and study plan

Liver biopsy

Procedure

patients with HCC or metastatic lesions will have a liver biopsy performed after the experimental MRI. This biopsy will be examined to confirm the imaging results

free-breathing MRI

Device

All patients will be asked to come in for an MRI scan using techniques developed which minimize the time a patient has to hold their breath to image the liver to <8 seconds and validate quantifiable techniques which improve liver image quality

Other names: experimental MRI

Primary outcomes

  1. Arterial Fraction

    Time frame: 1 day, At time of Research MRI

    Dynamic Contrast Enhanced MRI data were used to calculate three quantitative perfusion properties using a dual input, single tissue compartment model of gadolinium based contrast agents in the liver in HCC, metastatic, and benign lesions.

    One of these quantitative perfusion properties is Mean Arterial fraction, which is the proportion of blood flow derived from hepatic artery.

  2. Distribution Volume (DV)

    Time frame: 1 day, At time of Research MRI

    Dynamic Contrast Enhanced MRI data were used to calculate three quantitative perfusion properties using a dual input, single tissue compartment model of gadolinium based contrast agents in the liver in HCC, metastatic, and benign lesions.

    One of these quantitative perfusion properties is DV. DV corresponds to the volume of extracellular, extravascular space in a tissue which is a measure of the tissue cellularity

  3. Mean Transit Time (MTT)

    Time frame: 1 day, At time of Research MRI

    Dynamic Contrast Enhanced MRI data were used to calculate three quantitative perfusion properties using a dual input, single tissue compartment model of gadolinium based contrast agents in the liver in HCC, metastatic, and benign lesions.

    One of these quantitative perfusion properties is MTT. MTT corresponds to the average time, in seconds, that red blood cells spend within a determinate volume of capillary circulation

Secondary outcomes

  1. Free Breathing Quantification of Relaxation Parameters

    Time frame: Up to 1 year

    Quantified and validated relaxation parameters when creating T1 (spin-lattice) and T2 (spin-spin) weighted images

  2. Minimal Breathhold Time

    Time frame: 1 year

    The minimum time (in seconds) a patient must hold their breath to produce quality liver images during an MRI. Developing and validating a minimal breath-hold (< 8 s) high quality diffusion exam using highly accelerated steady state diffusion imaging sequences.

Sponsors and collaborators

Lead sponsor

Case Comprehensive Cancer Center

Other

Registry information

Important dates

Study start
2013
Primary completion
2019
Study completion
2019
First posted
Mar 26, 2014
Registry last updated
Jun 30, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.