UZ Leuven
Leuven, 3000, Belgium
NCT Number: NCT04847765
Previous research by TARGID (KU Leuven) has demonstrated the feasibility to assess gastric content volume by means of magnetic resonance imaging (MRI) while simultaneously evaluating gastric motor function by means of an isovolumetric balloon technique. This and other research concluded that in general, the motility readout of the isovolumetric balloon is associated with gastric contractions.
However, the exact relation between individual gastric contractions and individual intraballoon pressure waves remains incompletely understood.
Simultaneous assessment of gastric motility by means of an isovolumetric balloon and dynamic cine-MRI can validate that slow, high-amplitude intraballoon pressure waves are indeed induced by gastric muscle contractions. This evaluation might also enable us to attribute artefacts present in the pressure signal to physiologic processes such as cardiac, respiratory, intestinal and whole-body movements.
To date substantial uncertainty exists on the optimal procedural approach to evaluate gastric motility simultaneously with cine-MRI and the isovolumetric balloon.
The aim of this pilot study is to verify the feasibility of a several aspects of a larger confirmatory study protocol. This includes the evaluation of contrast of the balloon catheter on MRI (this would omit the need for radiographic confirmation), timelines, practical hurdles, analysis procedures and data management.
Looking for future studies?
Notify Me18 year and older
Male
Interventional
Not applicable
Leuven, 3000, Belgium
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The VIPUN Balloon Catheter prototype is a nasogastric feeding tube with integrated balloon that can be inflated with a preset volume of air. Intraballoon pressure changes are recorded outside the body. Gastric contractions can be detected in the pressure profile.
The recording lasts 30 minutes and is combined with simultaneous cine magnetic resonance imaging.
Time frame: 30 minutes
Analysis software filters the pressure signal and identifies individual gastric contractions.
The exact time at which each contraction is detected within a 30-minute recording period is documented.
Time frame: 30 minutes
The exact time at which each gastric contractile event is most clearly visible within a 30-minute recording period is documented.
Universitaire Ziekenhuizen KU Leuven
Other
A Pilot Study to Assess the Procedural Feasibility to Combine and Compare Dynamic Magnetic Resonance Imaging and an Isovolumetric Intragastric Balloon to Assess Gastric Contractility in Healthy Adults
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07721077
Health, Sport
Zhengzhou, Henan, China
View Trial DetailsNCT07589335
African Americans, Community Health Workers
Atlanta, Georgia, United States
View Trial DetailsNCT06747624
Health, Wellness
Palm Coast, Florida, United States
View Trial DetailsNCT06832670
Adherence Interventions, Adolescent Health
Kahramanmaraş, Eyalet/Yerleşke, Turkey (Türkiye)
View Trial Details