University of Health Sciences Bursa Yüksek İhtisas Training and Research Hospital
Bursa, Turkey (Türkiye)
NCT Number: NCT04407715
Different amounts of anesthetic gas can be used in the obstetric gynecological surgery operations to be performed with open method. Researchers aimed to compare the effect of gas changes on intraocular nerve diameter by ultrasonography.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Not applicable
Bursa, Turkey (Türkiye)
A total of 80 patients who underwent laparotomic gynecological surgery were divided into two groups prospectively: high flow of 2 L/min and minimal flow of 0.5 L/min. Anesthesia was maintained with 50% oxygen-50% air at 2 L/min and desflurane at 1.1 MAC in Group 1 (n=40) and with 50% oxygen-50% air at 2 L/min and desflurane at 1.1 MAC in Group 2 (n=40). After 10-15 minutes, group 2 was administered minimal flow with 50-60% oxygen-40-50% air at 0.5 L/min and desflurane, and 10 minutes before the end of the surgery, the patients were switched to high flow with 50% oxygen-50% air at 2 L/min.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The patients were randomly allocated to one of the two groups of fresh gas flows using the closed-envelope technique: 2 L/min high flow and 0.5 L/min minimal flow.
Time frame: 2 hours operation time
Optic nerve sheath diamater measurements of the patients were recorded before and during the surgery at specified time points (T0: awake, T1: High fresh gas flow after induction at the 10th min., T2: Inhalation anesthesia at the 30th min., T3: Inhalation anesthesia at the 60th min., T4: Inhalation anesthesia at the 90th min., T5: Before extubation).A typical optic nerve sheath is generally less than 5 mm in diameter, and diameters greater than 5.5 mm predict an ICP of ≥20 cm H2O with 100% sensitivity and specifity
Time frame: 2 hours operation time
Complications during the surgery (decreased oxygen levels, hypercapnia, hypotension, hypertension, bradycardia, tachycardia, rhythm disorders) were recorded.
Time frame: postop 20 minutes
Complications in the recovery room (respiratory distress, decreased oxygen levels, hypotension, hypertension, bradycardia, tachycardia, vomiting, rhythm disorders) were recorded.
Bursa Yuksek Ihtisas Training and Research Hospital
Other Gov
The Effect Of Minimal and High Flow Anesthesia on Optic Nerve Sheath Diameter in Laparotomic Gynecological Surgery
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07525648
Intracranial Pressure, Laparoscopic Surgery
Istanbul, Turkey (Türkiye)
View Trial DetailsNCT06979999
Intracranial Pressure, Mechanical Ventilation
Niğde, Niğde Province, Turkey (Türkiye)
View Trial DetailsNCT07521293
Arrhythmias, Cardiac, Atrial Fibrillation
Ankara, Turkey (Türkiye)
View Trial DetailsNCT06209034
Brain Diseases, Central Nervous System Diseases
Kocaeli, Turkey (Türkiye)
View Trial Details