NCT Number: NCT06519396

Achilles Tendon and Balance in Prediabetes

The aim was to evaluate the Achilles tendon size and static and dynamic balance, as well as the role of Achilles tendon on balance in prediabetes. A total of 96 patients were divided into three groups: 1)the control group, consisting of patients without diabetes; 2)the prediabetes group; 3)the diabetes mellitus group. Ultrasonographic measurements of Achilles tendon sizes were performed. Dynamic balance was assessed using the Berg Balance Scale, static balance was assessed.The Self-Leeds Assessment of Neuropathic Symptoms and Signs was utilized to identify neuropathic pain.

Completed

Looking for future studies?

Notify Me

Key information

Age range

40 year–65 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Fulya Bakilan

Eskişehir, Turkey (Türkiye)

About this study

Background/Aims: There is a lack of studies that examine balance problems and Achilles tendon thickness in prediabetes, despite their common occurrence in diabetes. The aim was to evaluate the Achilles tendon size and static and dynamic balance, as well as the role of Achilles tendon on balance in prediabetic patients.

Methods: A total of 96 patients were divided into three groups: 1)the control group, consisting of patients without diabetes; 2)the prediabetes group; 3)the diabetes mellitus group. Ultrasonographic measurements of Achilles tendon sizes (thickness, width and area) were performed. Dynamic balance was assessed using the Berg Balance Scale, static balance (the Fall Index, Stability Indexes) was assessed using a Tetrax device. The Self-Leeds Assessment of Neuropathic Symptoms and Signs was utilized to identify neuropathic pain.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • being between 40 and 65 years old

Exclusion criteria

  • extremity amputation
  • vitamin B12 deficiency
  • Type 1 Diabetes Mellitus
  • prior exposure to neurotoxic agents
  • peripheral neuropathy for reasons such as chronic kidney failure, liver failure, - hypothyroidism, hereditary and inflammatory peripheral neuropathies, neuromuscular diseases, malignancies
  • anti-neuropathic drug usage
  • radiculopathy
  • nerve trauma or surgery
  • vasculitis and autoimmune disorders
  • peripheral vascular disease
  • pregnancy
  • vestibular and cerebellar problems
  • history of lower extremity surgery
  • presence of medication affecting balance
  • history of alcoholism
  • presence of visual impairment.

Treatment and study plan

ultrasonography evaluation

Device

Ultrasonographic measurements of the Achilles tendon were taken using Samsung Sonoace X7 ultrasound system equipped with an 8-13MHz linear transducer. After assuming a prone position on the examination table, the patients placed their feet against the wall and flexed their ankles to ensure optimal contact between the probe and the tendon. Measurements were taken separately on the right and left sides for each patient. Initially, the probe was positioned perpendicular to the long axis of the tendon for an axial plane assessment, followed by measurements of thickness (anterior-posterior), width (medial-lateral), and area at the level of the medial malleolus. The thickness and width measurements utilized the tendon's major axes, while the area measurements were automatically calculated by the device through continuous tracing of the tendon circumference in the same section

tetrax device evaluation

Device

A Tetrax device was used to assess static balance. The patient was positioned on the platform and subjected to tests in eight different positions. For each position, a test measurement was made for a duration of 32 seconds, for a total of approximately 5 minutes. The normal eyes-open position was taken as the reference. The effects of vision on balance were observed in the eyes-closed position. Balance is dependent on the back of the heels and the lower vertebrae in this position. Conversely, in the eyes-closed position with the head tilted 30 degrees forward, there is a load on the upper vertebrae and neck. Following the measurements, the Tetrax software program was used to calculate the Fall Index and Stability Index

Primary outcomes

  1. ultrasonographic measurement of achilles tendon

    Time frame: baseline

    measurements of thickness (anterior-posterior), width (medial-lateral), and area of achilles tendon at the level of the medial malleolus were made

  2. balance measurement

    Time frame: baseline

    Static balance measurement were made with Tetrax Device

Sponsors and collaborators

Lead sponsor

Eskisehir Osmangazi University

Other

Registry information

Official study title

Ultrasonographic Achilles Tendon Measurements and Static and Dynamic Balance in Prediabetes

Important dates

Study start
2023
Primary completion
2023
Study completion
2023
First posted
Jul 25, 2024
Registry last updated
Jul 25, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.