Dep. of visceral and Transplant Surgery, Bern University Hospital
Bern, 3010, Switzerland
NCT Number: NCT01474694
Preoperative image-guided data correlates with the actual intraoperative reality. Computer-assisted preoperative planning combined with intraoperative mapping of even very small lesions allows for improved accuracy during complete oncological resection / ablation. In the short- and long-term this possibly results in better patient outcome.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Bern, 3010, Switzerland
Background
The aim of this study is to analyze the available accuracy of a computer-assisted approach to liver surgery and microwave ablation. The term 'computer-assisted' refers to 1) using 3D models of patient anatomy for extended orientation during the planning of the intervention and 2) using an image guidance system (similar to a GPS in a car) that allows for precise targeting of desired anatomical structures (e.g. intrahepatic tumor, bile ducts / vasculature) in the setting of successfully treating liver malignancies. Furthermore, we would like to demonstrate, that image guided open liver surgery is technically feasible, whenever the correlation between preoperative image-guided data and the intraoperative setting can be achieved with a known accuracy.
Eventually, this technology, like in other surgical domains, will lead to successively implemented technical guiding functionalities that could potentially improve patient outcome.
Objective
To date, first systems (CE marked medical devices) are available that have been specifically developed for image-guided open liver surgery. The systems tracks positions of surgical instruments in or near the target organs and visualizes the instruments position in correlation to patients medical image data (i.e. 3D-CT) on the computer screen. Surgeons benefit from a view to a virtual scene (on a computer screen) in which CT images, together with models of the vascular structures, tumors and organ boundaries, are intuitively visible. The surgeon can see the moving instrument, just like the movement of a car can be seen in a GPS system
Methods
In patients requiring extensive surgery (eg. extended right hemihepatectomy), accurate calculations of the remaining liver volume are essential to avoid postoperative liver failure with potentially serious postoperative complications or even death, resulting from an inadequate remaining liver volume (ie "small-for-size syndrome"). In high-risk liver resections, use of computer programs, such as MeVis (MeVis Medical Solutions Inc.), provide the surgeon with accurate preoperative information, allowing him / her to judge the feasibility of the planned surgical resection based on preoperative liver volume analysis and evaluation of the planned resection line in relation to essential structures (ie. major vessels / bile ducts).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The patient is placed in a supine position and standard laparotomy (either via subcostal, midline or inverted hockey-stick incision) is performed. After mobilization of the liver, surgical swabs are packed around the organ to prevent unnecessary movement of the liver during the acquisition of the landmarks and the subsequent surgical procedure
Time frame: 12 months
Time frame: 15 months
Insel Gruppe AG, University Hospital Bern
Other
Accuracy Assessment for Computer-assisted Surgical Interventions of the Liver: A Prospective, Non Randomized Study
Acronym: CALS
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04892810
Adenocarcinoma, Carcinoma
Grenoble, France
View Trial DetailsNCT04930315
Adenocarcinoma, Carcinoma
Hangzhou, Zhejiang, China
View Trial DetailsNCT05128032
Adenocarcinoma, Carcinoma
Boston, Massachusetts, United States
View Trial DetailsNCT04374877
Adenocarcinoma, Advanced Solid Tumor
Duarte, California, United States
View Trial Details