Skip to main content
OpenTrials
Completed

NCT Number: NCT01571557

A Safety and Efficacy Study to Assess OZURDEX® in Patients With Macular Oedema Secondary to Retinal Vein Occlusion (RVO)

This study will evaluate the relationship between time since onset of macular oedema symptoms and the achievement of vision gain in patients prescribed OZURDEX®. All care and diagnostic procedures provided are at the discretion of the participating physicians according to their clinical judgment and local standard of medical care.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Berlin, Germany

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Diagnosis of macular edema following retinal vein occlusion
  • Prescribed OZURDEX®

Exclusion criteria

  • Previous treatment with OZURDEX®

Treatment and study plan

dexamethasone 700 ug intravitreal implant

Drug

dexamethasone 700 ug intravitreal implant administered according to standard of care.

Other names: OZURDEX®

Primary outcomes

  1. Change From Baseline in Best Corrected Visual Acuity (BCVA) in the Study Eye

    Time frame: Baseline, Week 12

    BCVA is measured in the study eye following each injection of OZURDEX® using the Snellen eye chart. BCVA measurements expressed in Snellen fractions are converted to logMAR units and the approximate Early Treatment Diabetic Retinopathy Study (ETDRS) letter score is based on the formula: approximate ETDRS letters=85+50 x log10 (Snellen fraction). The converted scores are "approximate ETDRS letters" to distinguish the scores from visual acuity measurements obtained using the ETDRS chart. One line on the EDTRS equals 5 ETDRS points. The lower the number of letters read correctly on the eye chart (lower number on the decimal scale) the worse the vision (or visual acuity). The higher the number of letters read correctly (higher number on the decimal scale), the better the vision (or visual acuity). A positive number change from baseline in the number of letters read means vision has improved and a negative number change from baseline means vision has worsened.

Secondary outcomes

  1. Percentage of Patients With an Increase of ≥2 Lines From Baseline BCVA in the Study Eye

    Time frame: Baseline, 48 Weeks

    BCVA is measured in the study eye following each injection of OZURDEX® using the Snellen eye chart. BCVA measurements expressed in Snellen fractions are converted to logMAR units and the approximate ETDRS letter score is based on the formula: approximate ETDRS letters=85+50 x log10 (Snellen fraction). The converted scores are "approximate ETDRS letters" to distinguish the scores from visual acuity measurements obtained using the ETDRS chart. One line on the EDTRS equals 5 ETDRS points. The lower the number of letters read correctly on the eye chart (lower number on the decimal scale) the worse the vision (or visual acuity). An increase of 2 letters or more indicates an improvement in BCVA.

  2. Percentage of Patients With an Increase of ≥3 Lines From Baseline BCVA in the Study Eye

    Time frame: Baseline, 48 Weeks

    BCVA is measured in the study eye following each injection of OZURDEX® using the Snellen eye chart. BCVA measurements expressed in Snellen fractions are converted to logMAR units and the approximate ETDRS letter score is based on the formula: approximate ETDRS letters=85+50 x log10 (Snellen fraction). The converted scores are "approximate ETDRS letters" to distinguish the scores from visual acuity measurements obtained using the ETDRS chart. One line on the EDTRS equals 5 ETDRS points. The lower the number of letters read correctly on the eye chart (lower number on the decimal scale) the worse the vision (or visual acuity). An increase of 3 letters or more indicates an improvement in BCVA.

  3. Mean Change From Baseline in Central Retinal Thickness

    Time frame: Baseline, Week 24

    Retinal thickness is assessed by optical coherence tomography (OCT) in the study eye. The retina is the light-sensitive part of the eye. OCT is a laser-based, noninvasive, diagnostic system providing high-resolution, three-dimensional images of the retina. A negative mean change from baseline indicates an improvement and a positive mean change from baseline indicates a worsening.

Sponsors and collaborators

Lead sponsor

Allergan

Industry

Registry information

Important dates

Study start
2012
Primary completion
2014
Study completion
2014
First posted
Apr 5, 2012
Registry last updated
Apr 19, 2019

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.