Test lens
DeviceThe test lens is the Deseyne Daily Disposable soft contact lens
NCT Number: NCT06698731
The goal of this clinical trial is to learn if the contact lens we are testing will work to extend the range of clear focus at distance to provide an increase in clear vision at closer ranges without the additional need for bifocal lenses or reading correction.
The clinical study will compare the use of the test lens for extended range of focus (far to near) to a standardized contact lens designed for distance vision (far) (ie. Walking, driving, etc., where closer-in vision is not anticipated to be helpful, particularly in a population of users in the age range of 45-70.
We will also learn about the effectiveness of the lens to maintain good contrast in low illumination such as during evening and night-time periods.
The main questions we aim to address in the study are:
*. Does the contact lens provide adequate vision at distances closer to the patient such as during reading or computer usage?
* Whether the contact lens in use introduces any visual disturbance or safety concern as compared to a currently designed lens for distance use?
The study is designed to be conducted in the doctor's office:
* Using electronic vision measuring equipment familiar to the user. * A total of two visits are necessary to complete he study * All patients will experience using the test lens as well as the control lens during the study * No contâct lenses will be given to the study patients to take home. * It is anticipated that the total amount of time of participation in the study will be approximately 3 hours of your time over two separate visits.
Looking for future studies?
Notify Me45 year–70 year
All sexes
Interventional
Not applicable
Omega VisionCenter PA, Longwood, Florida, United States
The Deseyne daily disposable soft contact lens is intended for the correction of presbyopia and considered to be one of the growing class of extended depth of focus (EDOF) devices that uses a variety of strategies to provide useful intermediate and near vision. The lens is manufactured with vifilcon C material containing hyaluronic acid and tamarind seed polysaccharide, with a water content of 60% in a single diameter of 14.1 mm and base curve of 8.6 mm. The profile of the anterior surface is spherical across the 11-mm optic. Centrally, there is a 1.0 mm diameter zone that is optically inactive, contiguous with the optical zone. Light passes through the zone but is not intended to form a usable image. The central steep zone is at least 8.00 D steeper than the optical zone. The non-focusing central zone is intended to provide for an increased depth of focus, thus improving near and intermediate vision for the presbyopic patient.
Deseyne (vifilcon C) daily disposable soft contact lenses are proposed to be indicated for the optical correction of refractive ametropia (myopia and hyperopia) in non-diseased eyes with up to 1.00 D of astigmatism that does not interfere with visual acuity (VA).
A multicenter, randomized, active-controlled, double-masked, crossover study design will be used to compare the clinical performance of the Deseyne (vifilcon C) soft contact lens for Presbyopia EDOF (test) to the 1-Day Acuvue Moist (etafilcon A) soft contact lens for Single Vision (control). This is a 1-day crossover study (conducted over 2 visits) and will consist of approximately 75 subjects (75 study eyes [all study eyes will be right eyes]) randomly assigned in-office to wear the test or the control lens first. A 30-minute washout period will be scheduled between the crossover. Subjects must be otherwise healthy, with spectacle refraction between -6.00D and +4.00 D and astigmatism ≤1.00 D that does not interfere with VA.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The test lens is the Deseyne Daily Disposable soft contact lens
The control lens is the 1-Day AcuVue Moist Daily Disposable single vision contact lens
Time frame: Day 1
The primary effectiveness endpoint for the study is monocular (study [right] eye only) photopic negative lens-induced distance-corrected depth of focus (DOF) at the 0.2 logMAR VA threshold.. This is accomplished by adding small incremental negative lens power over the distance best corrected vision correction until blurred vision is determined (study eye only).
Time frame: Day 1
Method defines measurement of visual acuity through the distance correction contact lens measured at a distance of 66 cm from the patient.
Time frame: Day 1
Method is to test visual acuity through the distance contact lens correction at 40cm from the patient.
Bruno Vision Care
Industry
Acronym: EDOF
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07723716
Eye Diseases, Presbyopia
Seoul, South Korea
View Trial DetailsNCT05646719
Eye Diseases, Presbyopia
Phoenix, Arizona, United States
View Trial DetailsNCT07076160
Eye Diseases, Presbyopia
Jacksonville, Florida, United States
View Trial DetailsNCT07570602
Eye Diseases, Presbyopia
Bloomington, Indiana, United States
View Trial Details