Clinical Optics Research Lab
Bloomington, Indiana, 47405, United States
NCT Number: NCT07570602
Recent Android mobile device technology is available which allows user-measured refractive error and reading add power. This technology could be quite useful to the clinical and research community. The current study aims to evaluate the accuracy, repeatability, and reproducibility of one such technology by VisionApp, specifically with regard to refraction and presbyopia.
VisionApp is an app which runs on a smartphone or other device which uses the distance between the user's face and the phone to determine refractive error, while the user looks at different targets (lines, letters, words, etc).
Looking for future studies?
Notify Me40 year and older
All sexes
Interventional
Not applicable
Bloomington, Indiana, 47405, United States
Subjects will be enrolled at the Clinical Optics Research Lab at Indiana University and complete a single study visit.
At the study visit, demographic and health/ocular history may be collected by oral history and standard clinical testing including refraction (check of glasses prescription), auto-refraction or aberrometry may be performed. Visual acuity and room lighting checks may also be measured using standard clinical techniques.
For the experimental portion of the study visit, the subject will look at a phone running the VisionApp program set at a particular distance (calibration) and then be instructed to move further from, or closer to the phone, until a given target (letter, lines, patterns, etc) are more or less clear. Each test may be repeated until at least 10 good data points are collected. This may be done on the right eye, left eye, or both eyes.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
VisionApp is an app which runs on a smartphone or other device which uses the distance between the user's face and the phone to determine refractive error, while the user looks at different targets (lines, letters, words, etc).
Time frame: Day 1
Spherical equivalent refractive error in diopters will be compared between Myopia Check and traditional refraction.
Time frame: Day 1
Presbyopic near point in diopters as measured by the VisionApp technique and composite standard clinical measurements.
Indiana University
Other
Assessment of the Accuracy and Repeatability of the VisionApp - Refraction and Presbyopia Measurement Protocol
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06460389
Cataract, Eye Diseases
Alexandroupoli, Evros, Greece
View Trial DetailsNCT05431543
Eye Diseases, Myopia
Chandler, Arizona, United States
View Trial DetailsNCT05294328
Eye Diseases, Myopia
Glendale, California, United States
View Trial DetailsNCT05886907
Astigmatism, Eye Diseases
Johns Creek, Georgia, United States
View Trial Details