Peking University Third Hospital
Beijing, Beijing Municipality, 100191, China
NCT Number: NCT04462172
This prospective multicenter cohort study is to compare the post-operative implant failure rate between the patients with femoral neck fracture (AO classification 31-B) using Femoral Neck System (FNS) versus Multiple Cancellous Screws (MCS) at 2-year follow up. The patients are divided into the FNS group and the MCS group according to the internal fixation they choose. The internal fixation failure rate (IFFR) and differences in fracture prognosis of the two groups will be compared. Obtain clinical data of FNS in the Chinese population, and verify the safety and efficacy of FNS for patients with femoral neck fracture.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Beijing, Beijing Municipality, 100191, China
This is a prospective multicenter cohort study. The team leader is Peking University Third Hospital. All patients are divided into 2 groups according to the internal fixation they choose. Investigators use FNS for internal fixation in Group 1 and MCS in Group 2. Since FNS is clinically comparable to the Dynamic Hip Screw (DHS) system, investigators used DHS clinical data as a statistical reference. The relevant parameters of the sample calculation are α = 0.05 (one-sided) and β = 0.2. PASS 15 was used for calculation, and the final sample size was 290. The FNS group and the MCS group each included 145 patients. See the text for detailed inclusion and exclusion criteria. Patients that meet all the inclusion criteria but do not meet any exclusion criteria, and who have signed the informed consent will be recruited, and each patient will be assigned a unique patient identification number, which will be used throughout the study identify the patient. Investigators will perform preoperative preparation, intraoperative operation and internal fixation implantation according to the instructions provided in the product packaging. Investigators only plan to include cases that can successfully conduct closed reduction, therefore investigators will exclude cases that require open reduction. For the MCS group, three cancellous screws with an inverted triangle pattern are used to fix the fracture of femoral neck. After the operation, the patients will be managed according to the standard nursing and rehabilitation procedures of the experimental site and the results of laboratory tests will be recorded. Regular follow-up evaluation will be performed after the operation until the end of the two-year follow-up or the primary end point of the study. In this study, the internal fixation failure rate (IFFR) is used as the primary end point of the study, which is defined as the total incidence of internal plant cut-out and fracture. The results of the radiographic examination, the lateral X-ray film and computed tomography(CT), will be evaluated by an independent radiologist to determine whether there are cut-out or fracture of the internal plant. Secondary endpoints include: 1. Bone nonunion after 36 weeks: evaluate bone healing according to the lateral X-ray examination. According to the regulations of Food and Drug Administration of the US, it is defined as nonunion if there are no obvious signs of fracture healing 9 months after the fracture, or if there is no obvious difference in fracture space after three consecutive months. 2. Garden classification proportion, and Garden index for reduction assessment. 3. Clinical prognosis: o A 12-Item Short-Form Health Survey (SF-12) o Harris hip score. 4. Operation time, from the incision to internal fixation implanted. 5. The times of intraoperative fluoroscopy, average 25 milliseconds per X-ray shot, record the number of X-ray shot. 6. Postoperative adverse events within 2 years, including ipsilateral femoral head avascular necrosis, infection, wound hematoma, ipsilateral coxa vara, and ipsilateral limb shortening. In this study, it is difficult to blind anyone . Investigators will try their best to reduce human-induced bias in experimental results. Investigators will use one-sided α = 0.05 for statistical tests and confidence interval calculations. P value <0.05 is considered statistically significant. SPSS (latest version: SPSS Inc., Chicago, IL, USA) will be used to analyze the results.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
perform preoperative preparation, intraoperative operation and internal fixation implantation according to the instructions provided in the product packaging.
three cancellous screws with an inverted triangle pattern are used to fix the fracture of femoral neck.
Time frame: from operation to 1-year follow-up after the surgery
defined as the total incidence of internal plant cut-out and fracture.
Time frame: from operation to 1-year follow-up after the surgery
evaluate bone healing according to the lateral X-ray examination. According to the regulations of Food and Drug Administration of the US, if there are no obvious signs of fracture healing 9 months after the fracture, or if there is no obvious difference in fracture space after three consecutive months, it is defined as nonunion.
Time frame: At 1 year after the surgery
the scale of the score value is from 0 to 100, and a higher score means a better outcome
Time frame: intraoperative
from the incision to internal fixation implanted.
Time frame: intraoperative
average 25 milliseconds per X-ray shot, record the number of X-ray shot
Time frame: from operation to 1-year follow-up after the surgery
including ipsilateral femoral head avascular necrosis, infection, wound hematoma, ipsilateral coxa vara, and ipsilateral limb shortening
Time frame: from operation to 1-year follow-up after the surgery
Routine radiographs were taken to assess fracture reduction quality, which was categorized neutral, positive or negative support. Neutral Support: the medial cortex of the head-neck fragment is continuous with the medial cortex of the femoral shaft. Positive support: the medial cortex of the head-neck fragment lies medial to the medial cortex of the femoral shaft. Negative support: the medial cortex of the head-neck fragment lies lateral to the medial cortex of the femoral shaft.
Time frame: from operation to 1-year follow-up after the surgery
Since both implants are designed to allow for femoral neck shortening to allow fragment contact and bone healing. The amount of shortening primarily depends on the fracture configuration and bone quality.
Peking University Third Hospital
Other
A Prospective Multicenter Cohort Study About Internal Fixation Using Synthes Femoral Neck System (FNS) Versus Multiple Cancellous Screws (MCS) for Femoral Neck Fracture
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07702084
Blood Loss, Surgical, Femoral Fractures
Bursa, Turkey (Türkiye)
View Trial DetailsNCT06096883
Acetabulum; Protrusion, Femoral Fractures
Arnhem, Gelderland, Netherlands
View Trial DetailsNCT04577261
Femoral Fractures, Femoral Neck Fractures
Winston-Salem, North Carolina, United States
View Trial DetailsNCT07427082
Femoral Fractures, Femoral Neck Fractures
Gaziantep, Turkey (Türkiye)
View Trial Details