University Hospitals Cleveland Medical Center
Cleveland, Ohio, 44106, United States
NCT Number: NCT05975619
Cone beam computed tomography (CBCT) images are routinely used in radiation treatment delivery workflows to align patients with the treatment beam. Conventional CBCT image quality is sufficient for this task but not good enough for other radiotherapy-related tasks, such as contouring anatomical structures and calculating radiation dose distributions. HyperSight is a new CBCT imaging system manufactured by Varian Medical Systems. The purpose of this study is to evaluate the integration of the HyperSight imaging system with Varian's TrueBeam radiotherapy system, a linear accelerator with a C-arm gantry that rotates about the patient to delivery radiation to the target malignancy. HyperSight CBCT images will be acquired prospectively from patients who are receiving radiation treatment. The HyperSight/TrueBeam system will be used for imaging only; patients receive their radiation treatment on cleared devices and no aspect of their treatment is affected by participation in the study. HyperSight images collected during the study will be evaluated for quality and utility and compared to conventional CBCT images as well as fan beam CT images used for treatment planning.
This study is active but is not currently recruiting participants.
18 year and older
All sexes
Interventional
Not applicable
Cleveland, Ohio, 44106, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Note: if no IV contrast will be administered on study, patient may enroll without creatinine level documented. Contrast eligibility will be determined as per Appendix A.
Exclusion criteria
Subjects are scheduled for 1 to 5 HyperSight imaging sessions, which will occur on the same days as their standard clinical visits during planning and treatment delivery. A total of 5 to 10 HyperSight CBCT images will be acquired over all imaging sessions.
Time frame: 1-9 weeks
The percentage of images that are of sufficient quality for patient treatment plan generation.
Time frame: 1-9 weeks
Comparison of organ at risk (OAR) delineation on TrueBeam-HyperSight CBCT images to OAR delineation on conventional CBCT images, as well as on fan beam CT.
Time frame: 1-9 weeks
Assessed through calculated image metrics.
Time frame: 1-9 weeks
Assessed through expert observer evaluations of the images for utility in the radiotherapy workflow.
Time frame: 1-9 weeks
Assessed through a patient survey using the validated Six-Item State Anxiety Scale derived from the State-Trait Anxiety Inventory. Each of the six items in the survey are assigned a score from 1 to 4 indicating the patient's agreement to a statement such as "I am tense", where 1 represents "Not at all", and 4 represents "Very much so".
Time frame: 1-9 weeks
Assessed through comparison of dose-volume histogram (DVH) metrics extracted from the re-calculation of the patient's treatment plan on the HyperSight CBCT to DVH metrics from the patient's treatment plan originally calculated on the pre-treatment simulation fan-beam CT.
Time frame: 1-9 weeks
Evaluated by the number of instances where patient positioning and/or custom immobilization devices created for their standard-of-care radiation therapy were incompatible with system geometries of the TrueBeam-HyperSight system during imaging and clearance checks.
Time frame: 1-9 weeks
The time required to register a HyperSight CBCT to the patient's reference CT simulation image.
Time frame: 1-9 weeks
Assessed through a user-rated confidence (measured using a three-point scale: low/moderate/high).
Time frame: 1-9 weeks
In images where the center of rotation is shifted, the impact of the off-axis imaging on the HU accuracy will be evaluated by comparing dose-volume histogram metrics between the treatment plan generated on the off-axis HyperSight CBCT and DVH metrics from the patient's treatment plan, calculated on a fan-beam CT that does not have the same limited field of view as the CBCT.
Time frame: 1-9 weeks
Timing of workflow steps and processes including setup, imaging, alignment, and door-to-door time as compared to standard-of-care imaging processes, and compared to clinical models for hypothetical, generic clinics, using a time-driven, activity-based cost model.
Time frame: 1-9 weeks
Assessed through evaluation of internal motion volumes of organs-at-risk and targets, relative to diaphragm and/or vertebral body position, as compared to 4D-CT from standard-of-care simulation imaging.
Varian, a Siemens Healthineers Company
Industry
A Prospective Imaging Study of Target Definition and Radiation Planning Workflows on the Integrated TrueBeam-HyperSight System for Patients Receiving Radiation Therapy
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06576908
Abdominal Cancer, Head and Neck Cancer
Toronto, Ontario, Canada
View Trial DetailsNCT05524454
Abdominal Cancer, Breast Cancer
Maastricht, Limburg, Netherlands
View Trial DetailsNCT06634706
Distributed and Orphan Tumors, Head and Neck Cancer
View Trial DetailsNCT06187103
Breast Cancer, Breast Diseases
Baltimore, Maryland, United States
View Trial Details