NCT Number: NCT06187103
The primary objective of radiation therapy is to deliver a therapeutic dose of radiation precisely to the target while minimizing exposure to healthy surrounding tissues. Image-guided radiation therapy (IGRT) involves acquiring cone beam computed tomography (CBCT) scans just before or during treatment sessions. By comparing the CBCT images with the reference images from the treatment planning process, clinicians can make necessary adjustments to ensure precise targeting and account for any changes that may have occurred since the initial planning. Conventional CBCT technology is, however, limited by several factors including long acquisition times that result in motion artifacts in the image, smaller fields of view that limit the volume of anatomy that can be imaged, poor image quality that limits soft tissue visibility, and artifacts created by dense metal implants. This study will evaluate a novel CBCT imaging solution ("HyperSight") that has the potential to address the challenges of conventional CBCT.
This study is active but is not currently recruiting participants.
18 year and older
All sexes
Observational
Baltimore, Maryland, 21201-1544, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Patients receive standard of care radiation treatment on a Varian TrueBeam system equipped with HyperSight CBCT imaging. Images acquired for daily patient positioning from two different treatment fractions - typically one near the beginning of the treatment course and one at about the halfway point - will be analyzed for the study.
Time frame: 1 year
To evaluate the feasibility of HyperSight CBCT as a method for CBCT-based re-planning by measuring the fraction of patients whose HyperSight imaging meets criteria for potential CBCT-based treatment planning using HyperSight CBCT. The criteria include visibility of all key anatomical structures, image quality sufficient to contour anatomical structures, and clinically acceptable dose accuracy.
Time frame: 1 year
To break down the fraction of patients that meet criteria for potential CBCT-based treatment planning using HyperSight CBCT by anatomical site (head/neck, breast, lungs, upper GI tract, and pelvis).
Time frame: 1 year
To evaluate the imaging noise in HyperSight CBCT using clinical images and to compare this aspect of image quality to simulation CT images.
Time frame: 1 year
To evaluate contrast between adjacent anatomical structures in HyperSight CBCT using clinical images and to compare this aspect of image quality to simulation CT images.
Time frame: 1 year
To measure the contrast-to-noise ratio of HyperSight CBCT using clinical images and to compare this aspect of image quality to simulation CT images.
Time frame: 1 year
To evaluate the severity of motion artifacts observed in HyperSight CBCT using clinical images and to compare motion artifacts to simulation CT. Qualitative assessments will be performed by independent observers using a 5-point Likert scale.
Time frame: 1 year
To evaluate the severity of metal artifacts observed in HyperSight CBCT in head & neck patients with dental fillings and pelvis patients with hip prostheses and compare metal artifacts between HyperSight CBCT and simulation CT. Qualitative assessments will be performed by independent observers using a 5-point Likert scale, with a score of 1 representing very severe metal artifacts and a score of 5 representing little or no artifact..
Time frame: 1 year
To evaluate concordance of anatomical structures contoured on HyperSight with anatomical structures contoured on simulation CT as measured by the Dice Similarity Coefficient.
Time frame: 1 year
To evaluate concordance of anatomical structures contoured on HyperSight with anatomical structures contoured on simulation CT as measured by Hausdorff Distance.
Time frame: 1-9 weeks
To evaluate the number of breath holds required for patients with breast, thoracic, and upper GI malignancies during HyperSight CBCT imaging.
Time frame: 1-9 weeks
To evaluate patient experience of HyperSight imaging. Patients will be asked to fill out a questionnaire. Questions will use a 5-point Likert scale.
Time frame: 1 year
HyperSight CBCT images will be reconstructed with different levels of noise suppression and compared qualitatively to CT simulation images of the same patient to identify regions adversely affected by too much or too little noise suppression. This evaluation will be performed for 1-2 subjects in each anatomical region.
Time frame: 1 year
The ability of AI auto-contouring to accurately contour structures on Hy[erSight CBCT will be evaluated (i) via qualitative user feedback on the accuracy of the auto-generated contours, and (ii) quantitatively using overlap metrics (Hausdorff Distance and Dice Similarity Coefficient) to compare auto-generated critical organs at risk to anatomical structures manually contoured on HyperSight CBCT.
Varian, a Siemens Healthineers Company
Industry
Evaluation of Improved Onboard Patient Imaging With the HyperSight Platform on TrueBeam 4.1
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05524454
Abdominal Cancer, Breast Cancer
Maastricht, Limburg, Netherlands
View Trial DetailsNCT02906943
Breast Cancer, Breast Diseases
Hamilton, Ontario, Canada
View Trial DetailsNCT07524114
Breast Cancer, Breast Diseases
Toronto, Ontario, Canada
View Trial DetailsNCT07558447
Breast Cancer, Breast Diseases
Milan, Italy
View Trial Details