This study compares the results of the existing fibrinogen concentration monitoring technology to the Electrochemical-based device, a point-of-care and rapid method,using a small amount of extra blood obtained in Type A Aortic Dissection Surgery.
Interested in participating?
Request Info18 year and older
All sexes
Observational
Hangzhou, Zhejiang, 310009, China
Location status: Recruiting
Electrochemical-based device for rapid detection of fibrinogen is a novel POC diagnostic method, which is suitable for operating theatres and emergency rooms.
The novel fibrinogen detection based on Gel electrodes combined with immunobiosensing strategies and use magnitude of current to characterize the fibrinogen concentration , which will be a POC assay of fibrinogen detection for critically ill patients.
This single-center, prospective, observational pilot study will evaluate the analytical performance as well as compared to conventional Clauss laboratory reference method.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Part1 Phase I-Laboratory calibration. The electrochemical method was employed to detect the fibrinogen concentration of standard quality control materials with varying concentration gradients, and the corresponding current values were recorded for constructing a standard curve of fibrinogen concentration.
Phase II-Assay performance using clinical samples. Subject is 18 years and underwent routine hemostasis analysis. using human biological samples already collected for routine hemostasis analysis, The samples were centrifuged at 2500g for 15 min at room temperature, to obtain PPP (residual platelet count of <10 × 10^9/L) and stored at-20℃used for determination by electrochemical method within 2 weeks, Each clinical sample was tested three times
Part2
Inclusion criteria
Subject underwent surgery for acute type A aortic dissection at our hospital, Subject is 18 years, Subject requires routine TEG measurement, Subject use human fibrinogen concentrate during surgery.
Exclusion criteria
Use Extracorporeal Membrane Oxygenation after surgery, inability to obtain written informed consent
Electrochemical-based device for rapid detection of fibrinogen is a novel POC diagnostic method, which is suitable for operating theatres and emergency rooms.
Time frame: 1 day
Time frame: 1 day
Contact information is provided by the study sponsor or research team.
Second Affiliated Hospital, School of Medicine, Zhejiang University
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07218185
Afibrinogenemia, Blood Coagulation Disorders
Aurora, Colorado, United States
View Trial DetailsNCT05711524
Afibrinogenemia, Bleeding
New York, United States
View Trial DetailsNCT05634005
Afibrinogenemia, Anemia
Salt Lake City, Utah, United States
View Trial DetailsNCT05780125
Afibrinogenemia, Bleeding
San Donato Milanese, MI, Italy
View Trial Details