NCT Number: NCT00646048

A Phase I Evaluation of the Safety of the TriVascular Stent-Graft System in the Treatment of Abdominal Aortic Aneurysms

This study was a prospective observational study examined the safety of the TriVascular AAA Stent-Graft System in the elective treatment of patients with abdominal aortic aneurysms. Specifically, the study will evaluate the safety of the TriVascualr AAA Stent-Graft System, evaluate the ability to deliver the Tri-Vascular AAA Stent-Graft System to the desired location within the aorta, and evaluate the ability of the TriVascular AAA Stent-Graft to exclude the abdominal aortic aneurysm.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 1

Primary location

Harbor UCLA Medical Center, Torrance, California, United States

Loading trial locations.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male or infertile female
  • Have signed an informed consent form.
  • Are considered an appropriate candidate for open surgical repair of an abdominal aortic aneurysm.
  • at least one of the following: Abdominal aortic aneurysm >= 4.5 cm in diameter; aneurysm has increased in size by 0.5cm in last 6 months; maximum diameter of aneurysm exceeds 1.5 times the transverse dimension of an adjacent normal aortic segment; saccular aneurysm larger than 3 cm.
  • Have patent iliac or femoral arteries that allow endovascular access to the aneurysmal site with a 17F Delivery Catheter.

Exclusion criteria

  • A dissecting, acutely ruptured, or leaking aneurysm, or an acute vascular injury due to trauma.
  • A need for emergent surgery.
  • contraindication to undergoing angiography.
  • A Thoracic aortic aneurysm that requires treatment.
  • Presence of thrombus or atheroma in proximal aortic neck covering > 50% of the endoluminal surface.
  • Presence of diffuse atherosclerotic disease in either common iliac artery that reduces the iliac artery diameter to <7mm.
  • Congenital abnormalities in which the placement of the stent-graft will cause occlusion of major arterial flow. Such abnormalities should be evaluated(e.g. angiography or CT) prior to treatment.
  • Unstable angina
  • Morbid obesity or other clinical conditions that severely inhibit x-ray visualization of the aorta.
  • Connective tissue disease (e.g., Marfan's or Ehlers-Danlos syndrome.)
  • Hypercoagulable state.
  • Contraindication for anticoagulation.
  • Acute renal failure.
  • Active systemic infection.
  • less than 18 years of age.
  • Life expectancy less than 1 year.
  • Current, or anticipated participation within 1 year, in another research study involving an investigational device or new drug (with the exception of participation in the Lifeline Registry of Endovascular Therapy).
  • Other medical, social, or psychological issues that in the opinion of the investigator preclude them from receiving this treatment, and the procedures and evaluations pre- and post-treatment.

Treatment and study plan

TriVascular Stent-Graft System

Device

TriVascular Stent-Graft System

Primary outcomes

  1. Number of Participants Without a Device Related Adverse Events Within 1 Month of the Study Procedure.

    Time frame: 1 month

    Device related adverse events included, but were not limited to: Stent Graft Migration, Vessel dissection or perforation, stent graft occlusion, branch vessel occlusion, aneurysm rupture.

  2. Number of Participants Without a Type I, III, and/or IV Endoleak at 1 Month Follow-up Identified by Computed Tomography (CT).

    Time frame: 1 month

    A Type I endoleak is a persistent perigraft channel of blood flow that develops due to inadequate or ineffective seal at the graft ends (attachment zones). A Type III endoleak occurs in the midgraft region due to leakage through a defect in the graft fabric or between the segments of a multisegmental graft. A Type IV endoleak is seen on completion of angiography or subsequent contrast studies as any blush of contrast that is presumed to emanate from blood diffusion across the porous graft fabric or through small holes in the graft cause by sutures or stent struts.

Secondary outcomes

  1. Number of Participants Who Achieve Technical Success of the Stent Graft System.

    Time frame: Post procedure

    Technical success was defined as successful introduction of the delivery catheter into the arterial system at the time of the study procedure and successful delivery/deployment of the stent graft system to the intended location with the absence of device related surgical conversion and intra-operative mortality. Device related surgical conversion is defined as the inability to deliver or deploy the stent graft system, then subsequently surgically treating the patient.

Sponsors and collaborators

Lead sponsor

Boston Scientific Corporation

Industry

Registry information

Acronym: AAA IDE

Important dates

Study start
2003
Primary completion
2004
Study completion
2010
First posted
Mar 28, 2008
Registry last updated
Jan 28, 2011

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.