Trafford General Hospital
Manchester, United Kingdom
NCT Number: NCT03618771
Total knee replacement (TKR) is an established treatment for knee osteoarthritis and leads to a satisfactory outcome in over 75% of patients. However, up to 25% of patients are not entirely satisfied with their TKR. Patient dissatisfaction has been associated with inadequate functional outcome, especially during negotiation of stairs and slopes. This phenomenon, known as mid-flexion instability, is believed to be caused by excessive anterior-posterior motion of the implant during activities of daily living. This is characterised as a perception that the replaced knee is unsteady during certain tasks.
This study will compare the functional outcome of two implants that have been designed to provide patients with a functionally stable knee throughout its range of motion. The different design roles in preventing implant-related mid-flexion instability remain unknown. The functional outcome and stability of these implants will be tested non-invasively with 3D motion capture technology.
Looking for future studies?
Notify Me18 year–90 year
All sexes
Interventional
Not applicable
Manchester, United Kingdom
This study will compare the functional outcome of two implants that have been designed to provide patients with a functionally stable knee throughout its range of motion. The different design roles in preventing implant-related mid-flexion instability remain unknown.
The Medacta GMK-Sphere implant consists of a fully congruent medial compartment which allows freedom of movement in the lateral compartment. Both femoral and tibial components are also available in a range of 13 sizes, allowing the surgeon to find a 'best fit' for each patient. These design features are aimed to mimic the movement of a natural healthy knee, potentially preventing implant-related mid-flexion instability.
The DePuy Synthes Attune implant design aims to provide patients with optimal functional outcome. The femoral component of this implant has a gradually reducing radius, and the tibial component an S-shaped post-cam mechanism. These features are designed to facilitate smooth movement and stability during flexion.
The comparative functional outcomes and stability in gait, and other activities of daily living has not been established for the two different TKR design concepts. Functional assessments will be carried out on TKR patients pre- and post-operatively. These assessments will non-invasively quantify the knee's stability, range of motion, strength as well as walking kinematics using 3D motion capture technology. As mid-flexion instability is most notable during downhill walking, patients will be required to walk downhill on a treadmill as part of this study, to better investigate the phenomenon of mid-flexion knee instability.
This study will not involve any invasive procedure in addition to the standard of care. As such, the research burden is minimal. The main ethical issue may be that patients will not be randomised into one of the two proposed groups.
Patients will receive either the GMK-Sphere implant or the Attune implant according to their surgeon's usual practice. Surgeons who specialise in the GMK-Sphere implant will only implant the GMK-Sphere for this study, and surgeons who specialise in the Attune implant will only implant the Attune. This allows surgeons to undertake the prosthesis with which they are expert, and also limit potential surgical error in the case of surgeons having to randomise patients to different designs on the same list.
Patients will be seen by the trial team on 3 separate occasions:
Collection of baseline data during pre-admission clinic (standard care except physical tests):
All questionnaires ask different questions (although there is some overlap). Together, they give an overall view of the patients' perception of their general health and knee specific problems. As such, they are all deemed necessary for this investigation.
There are separate scoring sheets for these subjective quantitative scores. The results are typically presented as a Mean ± SD score for each questionnaire (provided the data is normally distributed). All are valid in the English language.
Collection of follow-up measures by trial team between operation and post-operative visit (standard care):
Collection of data during routine follow-up clinics:
6 weeks post-operation (standard care except physical tests):
12 weeks post-operation (standard care):
1 year post-operation (standard care except physical tests):
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Parts of the knee joint diseased by osteoarthritis are replaced by metal and plastic prostheses.
Other names: Medacta GMK Sphere Implant, DePuy Synthes Attune Implant
Time frame: Change from baseline at 1-Year
Gait of patients will be analysed pre-operatively, six-weeks post-operatively, and 1-year post-operatively by 3D motion capture technology. The change measured over time at 1-year will be the primary outcome.
Time frame: 1 year post-operatively
Patient satisfaction will be reported using a scale on a questionnaire which asks six questions on how happy patients were with their hospital experience/level of pain/functional ability post-operatively. The questionnaire also asks whether their expectations were met. The two satisfaction questions are answered on a scale of 'Very Satisfied/Satisfied/Unsure/Dissatisfied' by ticking the appropriate box. The four questions based on patient expectation are scored on a scale of 'Excellent/Good/Unsure/Poor' by ticking the appropriate box.
Time frame: Pre-operatively
A joint specific questionnaire which asks patients on the level of pain and function they believe to have in their affected knee (taking into consideration the past 4 weeks only). The questionnaire consists of 12 questions. Five of the questions are pain related, and seven are aimed at function. Each question has 5 options and is scored from 0-4, with 4 being the best and 0 being the worst pain/function. The best score is therefore 48 (no pain/good function), and the worst score is 0 (pain and poor function).
Time frame: 6 weeks post-operatively
A joint specific questionnaire which asks patients on the level of pain and function they believe to have in their affected knee (taking into consideration the past 4 weeks only). The questionnaire consists of 12 questions. Five of the questions are pain related, and seven are aimed at function. Each question has 5 options and is scored from 0-4, with 4 being the best and 0 being the worst pain/function. The best score is therefore 48 (no pain/good function), and the worst score is 0 (pain and poor function).
Time frame: 1 year post-operatively
A joint specific questionnaire which asks patients on the level of pain and function they believe to have in their affected knee (taking into consideration the past 4 weeks only). The questionnaire consists of 12 questions. Five of the questions are pain related, and seven are aimed at function. Each question has 5 options and is scored from 0-4, with 4 being the best and 0 being the worst pain/function. The best score is therefore 48 (no pain/good function), and the worst score is 0 (pain and poor function).
Time frame: Pre-operatively
A questionnaire on patients' perception of their overall health. The questionnaire focuses on generic health in 5 dimensions: Mobility, self-care, pain or discomfort, anxiety or depression and usual activities (including work, housework, leisure, family, and study). The questions are scored using an algorithm; the result of which relates to the health status of the patient. This score ranges between 0 (equivalent to death) to 1 (equivalent to full health). It also contains a visual analogue scale where patients have to choose on a scale of 0-100 how well they believe their general health to be on that particular day, where 0 is the worst health imaginable and 100 is the best health imaginable.
Time frame: 6 weeks post-operatively
A questionnaire on patients' perception of their overall health. The questionnaire focuses on generic health in 5 dimensions: Mobility, self-care, pain or discomfort, anxiety or depression and usual activities (including work, housework, leisure, family, and study). The questions are scored using an algorithm; the result of which relates to the health status of the patient. This score ranges between 0 (equivalent to death) to 1 (equivalent to full health). It also contains a visual analogue scale where patients have to choose on a scale of 0-100 how well they believe their general health to be on that particular day, where 0 is the worst health imaginable and 100 is the best health imaginable.
Time frame: 1 year post-operatively
A questionnaire on patients' perception of their overall health. The questionnaire focuses on generic health in 5 dimensions: Mobility, self-care, pain or discomfort, anxiety or depression and usual activities (including work, housework, leisure, family, and study). The questions are scored using an algorithm; the result of which relates to the health status of the patient. This score ranges between 0 (equivalent to death) to 1 (equivalent to full health). It also contains a visual analogue scale where patients have to choose on a scale of 0-100 how well they believe their general health to be on that particular day, where 0 is the worst health imaginable and 100 is the best health imaginable.
Time frame: Pre-operatively
A general Quality of Life score with 12 questions. It has mental and physical components which are scored from the same questions, using different algorithms. Each question is multiple choice, and the patient must tick one answer. Each answer corresponds to a standardised value, which is used in two algorithms to generate an overall score. One score is for the mental component and one is for the physical component. The physical standardized values are summed across all 12 items. 56.57706 is added to the sum to create the SF-12 physical score. 60.75781 is added to sum create the SF-12 mental score. Higher overall scores are better than lower scores.
Time frame: 6 weeks post-operatively
A general Quality of Life score with 12 questions. It has mental and physical components which are scored from the same questions, using different algorithms. Each question is multiple choice, and the patient must tick one answer. Each answer corresponds to a standardised value, which is used in two algorithms to generate an overall score. One score is for the mental component and one is for the physical component. The physical standardized values are summed across all 12 items. 56.57706 is added to the sum to create the SF-12 physical score. 60.75781 is added to sum create the SF-12 mental score. Higher overall scores are better than lower scores.
Time frame: 1 year post-operatively
A general Quality of Life score with 12 questions. It has mental and physical components which are scored from the same questions, using different algorithms. Each question is multiple choice, and the patient must tick one answer. Each answer corresponds to a standardised value, which is used in two algorithms to generate an overall score. One score is for the mental component and one is for the physical component. The physical standardized values are summed across all 12 items. 56.57706 is added to the sum to create the SF-12 physical score. 60.75781 is added to sum create the SF-12 mental score. Higher overall scores are better than lower scores.
Time frame: Pre-operatively
This asks questions not covered in the OKS on patient perception of their knee that are important to know following TKA. It focuses on other aspects of outcome other than joint pain and function. There are 12 questions in total, each starting with 'Are you aware of your knee joint...' followed by a daily situation such as driving/lying in bed etc. Each question has a possible of 5 answers: Never/Almost Never/Seldom/Sometimes/Mostly. Every question is scored 1 (never) to 5 (mostly) according to the selected response categories. Thus, the raw score ranges from 12 to 60. The raw score is linearly transformed to a 0-100 scale and then reversed to obtain the final score. For the final Forgotten Joint Score -12 a high score indicates good outcome.
Time frame: 6 weeks post-operatively
This asks questions not covered in the OKS on patient perception of their knee that are important to know following TKA. It focuses on other aspects of outcome other than joint pain and function. There are 12 questions in total, each starting with 'Are you aware of your knee joint...' followed by a daily situation such as driving/lying in bed etc. Each question has a possible of 5 answers: Never/Almost Never/Seldom/Sometimes/Mostly. Every question is scored 1 (never) to 5 (mostly) according to the selected response categories. Thus, the raw score ranges from 12 to 60. The raw score is linearly transformed to a 0-100 scale and then reversed to obtain the final score. For the final Forgotten Joint Score -12 a high score indicates good outcome.
Time frame: 1 year post-operatively
This asks questions not covered in the OKS on patient perception of their knee that are important to know following TKA. It focuses on other aspects of outcome other than joint pain and function. There are 12 questions in total, each starting with 'Are you aware of your knee joint...' followed by a daily situation such as driving/lying in bed etc. Each question has a possible of 5 answers: Never/Almost Never/Seldom/Sometimes/Mostly. Every question is scored 1 (never) to 5 (mostly) according to the selected response categories. Thus, the raw score ranges from 12 to 60. The raw score is linearly transformed to a 0-100 scale and then reversed to obtain the final score. For the final Forgotten Joint Score -12 a high score indicates good outcome.
Time frame: Pre-operatively
Knee strength in Newton meters will be assessed using motion capture technology and a dynamometer
Time frame: 6 weeks post-operatively
Knee strength in Newton meters will be assessed using a dynamometer.
Time frame: 1 year post-operatively
Knee strength in Newton meters will be assessed using a dynamometer.
Time frame: Pre-operatively
Knee range of motion in degrees will be assessed using motion capture technology
Time frame: 6 weeks post-operatively
Knee range of motion in degrees will be assessed using motion capture technology
Time frame: 1 year post-operatively
Knee range of motion in degrees will be assessed using motion capture technology.
Manchester University NHS Foundation Trust
Other Gov
The Functional Outcomes and Stability of Total Knee Replacement Design Concepts
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07717957
Arthritis, Joint Diseases
Kuantan, Pahang, Malaysia
View Trial DetailsNCT07291791
Arthritis, Joint Diseases
Ismailia, Egypt
View Trial DetailsNCT03112200
Arthritis, Bone Marrow Edema
Encinitas, California, United States
View Trial DetailsNCT07568691
Arthritis, Balance Board
Jakarta Pusat, DKI Jakarta, Indonesia
View Trial Details