Skip to main content
OpenTrials
Completed

NCT Number: NCT02026245

A Comparison of Two Electronic Gloves in the Measurement of Joint Movement in Patients With Rheumatoid Arthritis

In this study we will compare two electronic goniometric gloves to see if they can be used in research on joint movement in arthritis.

One of the gloves we will use is the commercially available '5DT Ultra 14 glove', the other is a glove that we have specially designed and developed for use in people with arthritis. Both gloves are 'high-end' gloves with sensors for all of the finger and thumb joints.

We aim to find out if the gloves are accurate and if they can be worn and used without too much discomfort by people with arthritis.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–80 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Western Health and Social Care Trust

Londonderry, BT47 1SB, United Kingdom

About this study

This is an open pilot study to assess the usability and accuracy of two electronic goniometric gloves in measuring finger joint movement in patients with Rheumatoid Arthritis.

We will use questionnaires to assess pain, stiffness and disability. We will be using an inner disposable glove worn under the electronic goniometric gloves as this will be important for infection control in clinical use.

We will calibrate the electronic goniometric gloves using wooden blocks at predefined angles using our own software calibration process to optimise the accuracy of the glove for the individual patient.

The patient will flex and extend their fingers repeatedly to get measurements of the minimum and maximum angle of flexion in their joints. During these movements we will also capture the dynamic characteristics of movement such as maximum velocity. In this study a laptop will be used to capture and record all of the measurements from the electronic goniometric glove and record the time at which the measurements were taken.

Each electronic goniometric glove will be refitted for a second set of tests to assess variability due to the fitting process. We will record a full set of data from each set of movements for later analysis.

Finally, we will assess usability and establish if patients have a preference between the two electronic goniometric gloves.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male and female patients aged 18 to 80
  • Diagnosis of Rheumatoid arthritis
  • Patients who have significant pain and stiffness in their hands
  • Correct hand size to achieve a good fit to the electronic goniometric glove

Exclusion criteria

  • Poor fit for the disposable surgical glove
  • Severe pain in the right hand
  • Severe swelling in the right hand (rated as such by the investigator)
  • Major permanent deformities in the right hand
  • Active hyperextension >30 degrees in any joint of the right hand
  • Broken or infected skin in the right hand
  • Known to have tested positive for Methicillin resistant staphylococcus aureus (MRSA) skin infections in the past
  • Unable to don the lining disposable glove without significant discomfort
  • History of Latex allergy

Treatment and study plan

Data gloves to perform movements

Device

Using the electronic data gloves to perform a set routine of movements:

  • 5DT 'dataglove 14 Ultra' Electronic glove (commercially available)
  • New 'Tyndall/UU' developmental dataglove

Other names: 5DT, Tyndall/UU dataglove

Primary outcomes

  1. The accuracy of joint angle measurement by each electronic goniometric glove will be compared with the accuracy of manual goniometry.

    Time frame: 1 day

    The standard error of measurement for each electronic goniometric glove will be used to evaluate the reliability of each electronic goniometric glove. This will be compared to the standard error of measurement for manual goniometry.

Secondary outcomes

  1. The variability in the measurement of joint movement velocity

    Time frame: 1 day

    With rapid repeated movements of finger flexion and extension, the measured maximum velocity of movement should remain fairly constant. The intraclass correlation coefficient will be used to assess the variability in the measurement of joint movement velocity.

  2. Variability of joint angle measurements by the electronic goniometric gloves will be assessed

    Time frame: 1 day

    The Intraclass Correlation coefficient for joint angle measurement will be measured for each electronic goniometric glove

  3. The number of patients who withdraw or refuse to continue

    Time frame: 1 day

    Electronic goniometric gloves may not be easy to don and doff in patients with arthritis, particularly if used with an inner disposable glove. Because of the small numbers we will not apply a statistical analysis

  4. Variation in joint angle movement between fit and refit

    Time frame: 1 day

    If a electronic goniometric glove relies on accurate sensor positioning, refitting may give widely varying results. Each glove will be refitted once.

  5. Variation in joint angle measurement across the range of movement

    Time frame: 1 day

    With use of electronic goniometric gloves, joint angle measurement may be less accurate at the extremes of movement

  6. Variation in joint angle movement across sensors - between digits

    Time frame: 1 day

    Although it may be assumed that the sensors in each digit should perform equally well, the movement of the stretch sensors over the joints may vary between digits. This analysis will test for this variability

  7. The number of patients who prefer one electronic goniometric glove over the other

    Time frame: 1 day

    We will ask the patient which electronic goniometric glove they prefer. This will assess usability factors such as comfort, neatness of fit, and ease of donning and doffing.

  8. The variation in joint angle measurement with force applied

    Time frame: 1 day

    We will use the Intra class correlation test to determine if the accuracy of measurements is affected by the patient gripping tightly against a moulded object held in the palm of their hand.

  9. We will test the variability of joint angle measurements in wrist extension/flexion

    Time frame: 1 day

    We will compare the Intraclass Correlation coefficient for joint angle measurements carried out using the electronic goniometric glove in wrist extension/flexion

Sponsors and collaborators

Lead sponsor

University of Ulster

Other

Collaborators

  • Western Health and Social Care Trust

Registry information

Official study title

A Comparison of Two Electronic Goniometric Gloves in the Measurement of Joint Movement in Patients With Rheumatoid Arthritis

Important dates

Study start
2016
Primary completion
2017
Study completion
2017
First posted
Jan 1, 2014
Registry last updated
Nov 6, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.