In this study we will compare two electronic goniometric gloves to see if they can be used in research on joint movement in arthritis.
One of the gloves we will use is the commercially available '5DT Ultra 14 glove', the other is a glove that we have specially designed and developed for use in people with arthritis. Both gloves are 'high-end' gloves with sensors for all of the finger and thumb joints.
We aim to find out if the gloves are accurate and if they can be worn and used without too much discomfort by people with arthritis.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Interventional
Not applicable
Londonderry, BT47 1SB, United Kingdom
This is an open pilot study to assess the usability and accuracy of two electronic goniometric gloves in measuring finger joint movement in patients with Rheumatoid Arthritis.
We will use questionnaires to assess pain, stiffness and disability. We will be using an inner disposable glove worn under the electronic goniometric gloves as this will be important for infection control in clinical use.
We will calibrate the electronic goniometric gloves using wooden blocks at predefined angles using our own software calibration process to optimise the accuracy of the glove for the individual patient.
The patient will flex and extend their fingers repeatedly to get measurements of the minimum and maximum angle of flexion in their joints. During these movements we will also capture the dynamic characteristics of movement such as maximum velocity. In this study a laptop will be used to capture and record all of the measurements from the electronic goniometric glove and record the time at which the measurements were taken.
Each electronic goniometric glove will be refitted for a second set of tests to assess variability due to the fitting process. We will record a full set of data from each set of movements for later analysis.
Finally, we will assess usability and establish if patients have a preference between the two electronic goniometric gloves.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Using the electronic data gloves to perform a set routine of movements:
Other names: 5DT, Tyndall/UU dataglove
Time frame: 1 day
The standard error of measurement for each electronic goniometric glove will be used to evaluate the reliability of each electronic goniometric glove. This will be compared to the standard error of measurement for manual goniometry.
Time frame: 1 day
With rapid repeated movements of finger flexion and extension, the measured maximum velocity of movement should remain fairly constant. The intraclass correlation coefficient will be used to assess the variability in the measurement of joint movement velocity.
Time frame: 1 day
The Intraclass Correlation coefficient for joint angle measurement will be measured for each electronic goniometric glove
Time frame: 1 day
Electronic goniometric gloves may not be easy to don and doff in patients with arthritis, particularly if used with an inner disposable glove. Because of the small numbers we will not apply a statistical analysis
Time frame: 1 day
If a electronic goniometric glove relies on accurate sensor positioning, refitting may give widely varying results. Each glove will be refitted once.
Time frame: 1 day
With use of electronic goniometric gloves, joint angle measurement may be less accurate at the extremes of movement
Time frame: 1 day
Although it may be assumed that the sensors in each digit should perform equally well, the movement of the stretch sensors over the joints may vary between digits. This analysis will test for this variability
Time frame: 1 day
We will ask the patient which electronic goniometric glove they prefer. This will assess usability factors such as comfort, neatness of fit, and ease of donning and doffing.
Time frame: 1 day
We will use the Intra class correlation test to determine if the accuracy of measurements is affected by the patient gripping tightly against a moulded object held in the palm of their hand.
Time frame: 1 day
We will compare the Intraclass Correlation coefficient for joint angle measurements carried out using the electronic goniometric glove in wrist extension/flexion
University of Ulster
Other
A Comparison of Two Electronic Goniometric Gloves in the Measurement of Joint Movement in Patients With Rheumatoid Arthritis
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT01867840
Arthritis, Arthritis, Gouty
Nice, France
View Trial DetailsNCT05289544
Arthritis, Arthritis, Rheumatoid
Columbia, South Carolina, United States
View Trial DetailsNCT03404245
Arthritis, Arthritis, Rheumatoid
Vancouver, British Columbia, Canada
View Trial DetailsNCT05116163
Arthritis, Arthritis, Rheumatoid
Boston, Massachusetts, United States
View Trial Details