Peking Union Medical College Hospital
Beijing, Beijing Municipality, 100730, China
NCT Number: NCT07796542
Anemia is a common condition, but it often goes undiagnosed because confirming it requires a venous blood test. This study looks at whether a commercially available wrist-worn smartwatch can help identify people who may have anemia, without taking blood.
The watch continuously records several types of physiological signals, including photoplethysmography (a light-based measure of blood flow), movement, heart rate, blood oxygen saturation, and heart rate variability. Researchers will use these signals to build a computer model that sorts participants into two groups: likely to have anemia, or unlikely to have anemia.
About 400 adults between 18 and 80 years of age will take part at one hospital in Beijing, China. Both patients with anemia and people with normal hemoglobin levels will be included. Each participant will wear the watch and also have a standard venous blood test to measure hemoglobin, which serves as the reference for comparison.
Data from the first 250 participants will be used to develop the model. Data from the next 150 participants will be used to test how well the model works in a separate group. The main question is how accurately the watch-based result matches the blood test result.
Trial opening soon.
Get Notified18 year–80 year
All sexes
Observational
Beijing, Beijing Municipality, 100730, China
This is a prospective, observational, diagnostic accuracy study conducted at a single tertiary care hospital in Beijing, China. The purpose is to develop and evaluate a deep learning model for non-invasive binary classification of anemia using multimodal physiological signals acquired from a commercially available consumer wrist-worn wearable device.
Study procedures. Participants will be enrolled in two sequential stages. In the first stage, 250 participants will be enrolled for algorithm development and tuning. In the second stage, an additional 150 participants will be enrolled for independent testing of the locked model and for supporting iterative optimization. All participants will undergo wearable signal acquisition and venous blood sampling for hemoglobin measurement, which serves as the reference standard.
Signal acquisition differs by care setting. Hospitalized participants will undergo 24-hour continuous wearable monitoring and paired signal acquisition before and after a six-minute walk test. Outpatient participants will undergo short-duration resting acquisition with the device worn alternately on the left and right wrist. Outpatient participants may undergo up to three additional assessments if they return for routine clinical visits; these visits are opportunistic and recorded as they occur. Hospitalized participants undergo a single acquisition without follow-up.
Reference standard. Anemia is defined according to Chinese sea-level criteria: hemoglobin below 120 g/L in adult men, below 110 g/L in non-pregnant women, and below 100 g/L in pregnant women.
Sample size. The primary endpoint is diagnostic sensitivity. Assuming an expected sensitivity of 70%, an allowable error of 6%, and a confidence level of 95%, at least 225 participants with anemia are required. Allowing for approximately 10% dropout or unusable data, the anemia group is set at 300 or more participants. At least 90 participants with normal hemoglobin will be enrolled to estimate specificity. To support deep learning model training and generalizability assessment, the total target enrollment is 400 participants.
Statistical analysis. Model performance will be reported as sensitivity and specificity. Cross-validation will be used to assess model stability, and an independent test set will be used to assess generalizability.
The wearable device is non-invasive. Study participation does not alter any aspect of the clinical management of participants.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: Day 1
Agreement between the model-derived anemia versus non-anemia classification and venous hemoglobin measurement as the reference standard. Venous blood sampling is performed within 3 days before or after wearable signal acquisition.Reported as sensitivity and specificity with 95% confidence intervals in the independent validation cohort.
Time frame: Day 1
Sensitivity and specificity of the model using signals acquired during 24-hour continuous wearable monitoring in hospitalized participants.
Time frame: Day 1
Model sensitivity and specificity stratified by red blood cell size category (microcytic, normocytic, macrocytic) based on mean corpuscular volume
Time frame: Day 1 (immediately before and after the six-minute walk test)
Comparison of model classification performance using signals acquired before versus after a six-minute walk test in hospitalized participants.
Time frame: Day 1
Concordance of the model-derived anemia classification between signals acquired with the device worn on the left wrist and on the right wrist in outpatient participants.
Contact information is provided by the study sponsor or research team.
Jian Li, PhD
CONTACT
Miao Chen, PHD
CONTACT
Peking Union Medical College Hospital
Other
Acronym: WEAR-ANEMIA
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07788703
Anemia, Anemia, Neonatal
Kuala Lumpur, Malaysia
View Trial DetailsNCT07771192
Anemia, Hematologic Diseases
Angers, France
View Trial DetailsNCT07761104
Anemia, Hematologic Diseases
Lyon, France
View Trial DetailsNCT07493772
Anemia, Hematologic Diseases
Dar es Salaam, Tanzania
View Trial Details