28 mm ceramic head on ceramic acetabular liner.
DeviceTotal hip replacement with 28 mm ceramic head on ceramic liner articulation
Other names: Delta Ceramax™ 28 mm Ceramic-on-Ceramic Acetabular Cup
NCT Number: NCT00208507
The study is designed to evaluate artificial hips with a 28 mm ceramic head and a ceramic liner to determine whether they perform as well as artificial hips with a 28 mm ceramic head and a polyethylene liner.
Looking for future studies?
Notify Me20 year–75 year
All sexes
Interventional
Not applicable
Colorado Joint Replacement, Denver, Colorado, United States
Total Hip Arthroplasty (THA) is the surgical reconstruction of the hip joint through replacement of the femoral head and the acetabular articulating surfaces with fixed prosthetic devices. The goals of THA are relief from pain, restoration of function, and correction of deformity. THA is one of the most common adult reconstructive procedures. Over the past 25 years, patients who have needed to have their hip joint replaced, either due to trauma or arthritic disease, typically have had their hip joint bone articular surfaces replaced with a metal hip stem, metal ball head (either stainless steel or chrome cobalt) and a plastic acetabular cup (metal/metal/plastic). While the basic device has remained essentially unchanged over that period, technological advancements in implant designs and materials, and improvements in surgical technique and instrumentation have made THA one of the most durable and successful procedures in medicine. Reproducible, high-quality, short-term and mid-term results are attained regularly, and total hip replacements commonly last 10 to 15 years and longer. The success of this procedure has allowed its expansion into a wider, and often younger and more active population.
In spite of the improvements in THA, little change has occurred for the acetabular cup liner, which is usually made out of Ultra High Molecular Weight Polyethylene plastic (UHMWPe). Because it is plastic and inherently soft and somewhat pliable under load, the cup's articular surface must inevitability wear and produce debris. This biologic response is now thought to be a significant contributor to prosthetic component loosening, a primary failure mode of THR. UHMWPe also degrades with time in the body. As concerns about polyethylene wear and the associated untoward effects of the generated wear debris, and as THA continues to be used in younger and higher-demand patients with increasing life expectancies, interest in ceramic on ceramic total hip prosthesis has been renewed.
An alumina ceramic-on-ceramic acetabular coupling has been employed as an alternative to metal/polyethylene couplings. This ceramic-on-ceramic coupling has many advantages, including the elimination of polyethylene from the device system, wear rates that are appreciably less than those experienced with metal/polyethylene couplings and reduced biologic reactivity. The potential benefits of an alumina ceramic/ceramic bearing are significant.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Total hip replacement with 28 mm ceramic head on ceramic liner articulation
Other names: Delta Ceramax™ 28 mm Ceramic-on-Ceramic Acetabular Cup
Total hip replacement with 28 mm ceramic head on a polyethylene liner articulation.
Other names: Detla Ceramax 28 mm ceramic femoral head and Marathon polyethylene liner.
Time frame: The Harris Hip Total Score evaluation took place at 6 weeks, 6 months, 12 months, and a final evaluation at 24 months or greater (up to 96 months)
The Harris Hip scoring system assigns a numeric value to responses from patients and assessments made by a surgeon. Scores ranges from a minimum of zero to a maximum score of 100. A score of 91-100 is excellent, 81-90 is good, 71-80 is fair, 70 or below is poor. The patient records the following: pain level, need for assistance when walking, presence of a limp, distance able to walk, ability to put on shoes and socks, climb stairs, use public transportation and the length of time one is able to comfortably sit in a chair are all scored.
Time frame: The Complication Rates were evaluated at 6 weeks, 6 months, 12 months, and a final evaluation at 24 months or greater (up to 96 months)
Complication Rates are reported by each type of complication (adverse events/AEs) in the Adverse Events Tab
DePuy Orthopaedics
Industry
Delta Ceramax™ Ceramic-on-Ceramic Acetabular Cup Prosthesis Study (28mm)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05564182
Arthralgia, Behavior
Afyonkarahisar, Turkey (Türkiye)
View Trial DetailsNCT07009912
Arthritis, Joint Diseases
Kensington, Whangarei, New Zealand
View Trial DetailsNCT07188493
Arthritis, Joint Diseases
Lodz, Poland
View Trial DetailsNCT02717559
Anterior Cruciate Ligament Injuries, Arthritis
View Trial Details