Skip to main content
OpenTrials
Completed

NCT Number: NCT00418067

Zotarolimus-Eluting Stent Versus Sirolimus-Eluting Stent and PacliTaxel-Eluting Stent for Coronary Lesions

The purpose of this study is to establish the safety and long-term effectiveness of coronary stenting with the ABT 578-eluting balloon expandable stent (Medtronic, Minneapolis, MN) vs. the sirolimus-eluting balloon expandable stent (Cordis Johnson & Johnson, Warren, New Jersey) and the paclitaxel-eluting stent (Taxus liberte, Boston Scientific) for the treatment of coronary stenosis in routine clinical practice.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 4

Primary location

Soonchunhyang University Bucheon Hospital, Bucheon-si, South Korea

Loading trial locations.

About this study

Previous studies have documented that a slow-release polymeric sirolimus-eluting stent (Cypher, Cordis) and paclitaxel-eluting stent (Taxus, Boston Scientific) reduce neointimal formation and result in decrease of angiographic restenosis and target lesion revascularization at 1-3 years in the multicenter randomized clinical trials RAVEL, SIRIUS, and TAXUS I-VI.From these studies, the two leading drug-eluting stents (DESs) of the Cypher and Taxus have been widely and rapidly accepted as a standard treatment of coronary lesions.

Recently, randomized studies were conducted to reveal different outcomes of the different two DESs. These studies showed that the sirolimus-eluting stent was better than the paclitaxel-eluting stent in terms of lower angiographic restenosis rate or the two DESs were similar in angiographic outcomes. A recent meta-analysis supported results of the former randomized studies. Patients receiving sirolimus-eluting stent had a significantly lower risk of restenosis and target vessel revascularization compared with those receiving paclitaxel-eluting stent.

With a recent approval of new DES, ABT-578-eluting stent (Endeavor, Medtronic, Minneapolis, MN), other comparison studies have been conducted to compare Endeavor ABT-578-eluting stent with the sirolimus-eluting stent and paclitaxel-eluting stent. ABT-578 and sirolimus share some common structural and biological properties. The ENDEAVOR clinical trials are currently in progress to evaluate a phosphoryl choline (PC)-coated ABT-578-eluting stent for the prevention of restenosis. The Endeavor ABT-578-eluting stent utilizes a cobalt alloy balloon-expandable stent (Driver; Medtronic) with a geometry similar to the stainless steel stent used in this preliminary study (S7; Medtronic). The Endeavor ABT-578-eluting stent also employees a PC strut surface coating as the drug delivery reservoir with a dose of 10 ug/mm of ABT-578. The Endeavor ABT-578-eluting stent, however, differs from the stent used in this experimental study by the addition of a drug-free PC coating to serve as a diffusion barrier to retard drug release from the polymer reservoir. Angiographic analysis at 4 months in the 100-patient focal de novo lesion ENDEAVOR I feasibility study demonstrated a mean in-stent percent diameter stenosis of approximately 14% and a late lumen loss of 0.3 mm with a low frequency of target lesion revascularization (1%). The clinical outcomes from the ENDEAVOR II (1,500 patients randomized to ABT-578 or bare metal stent) and the ENDEAVOR III (436 patients randomized 3:1 to ABT-578 or Cypher) trials as well as other ongoing studies showed efficacy of the PC-coated ABT-578-eluting stent. In ENDEAVOR III study, the Endeavor stent had larger late loss and higher binary restenosis in both the analysis segment and stented segment. In contrast, the TLR rates are not statistically different between the Endeavor (6.0%) and the Cypher (5.3%, p=1.0) stents. This result of this study raised several questions to warrant further randomized studies 1) is the angiographic superiority of Cypher stent applied to the more complex lesions, 2) why is the TLR rate similar in spite of significantly different angiographic outcomes, 3) which is better in the Endeavor and the Taxus stents, etc. The ENDEAVOR IV study is being conducted to compare the safety and efficacy of the Endeavor stent versus the Taxus stent. However, the inclusion of ENDEAVOR IV study was also limited that this study did not include all complex lesions. Because of the limitations of current ENDEAVOR series, a further large randomized study for the concurrent comparison of the three DESs in the treatment of real-world practice would be needed.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • The patient must be at least 18 years of age.
  • Significant coronary artery stenosis (>50% by visual estimate)
  • Patients with stable (CCS class 1 to 4) or acute coronary syndromes (unstable angina pectoris class IB, IC, IIB, IIC, IIIB, IIIC or NSTEMI) or patients with atypical chest pain or without symptoms but having documented myocardial ischemia, amenable to stent-assisted percutaneous coronary intervention
  • The patient or guardian agrees to the study protocol and the schedule of clinical and angiographic follow-up, and provides informed, written consent, as approved by the appropriate Institutional Review Board/Ethical Committee of the respective clinical site.

Exclusion criteria

  • The patient has a known hypersensitivity or contraindication to any of the following medications:
  • Heparin, Aspirin, Both Clopidogrel and Ticlopidine, Sirolimus, paclitaxel, ABT 578, Stainless steel and/or Contrast media (patients with documented sensitivity to contrast which can be effectively pre-medicated with steroids and diphenhydramine [e.g. rash] may be enrolled. Patients with true anaphylaxis to prior contrast media, however, should not be enrolled).
  • Female of childbearing potential, unless a recent pregnancy test is negative, who possibly plan to become pregnant any time after enrollment into this study.
  • Current known current platelet count <100,000 cells/mm3 or Hgb <10 g/dL.
  • An elective surgical procedure is planned that would necessitate interruption of antiplatelet drugs during the first 12 months post enrollment.
  • Non-cardiac co-morbid conditions are present with life expectancy <1 year or that may result in protocol non-compliance (per site investigator's medical judgment).
  • Patients who are actively participating in another drug or device investigational study, which have not completed the primary endpoint follow-up period.
  • Patients who have target lesion of in-stent restenosis at the stented segment of drug-eluting stent (in-stent restenosis of bare metal stent can be included).
  • Patients with EF<30%.
  • Patients with cardiogenic shock
  • Acute STEMI patients within symptom onset < 12 hours needing primary angioplasty
  • Creatinine level > 3.0mg/dL or dependence on dialysis.
  • Severe hepatic dysfunction (AST and ALT > 3 times upper normal reference values).
  • Patients with left main stem stenosis (>50% by visual estimate)

Treatment and study plan

Endeavor

Device

Zotarolimus-eluting stent

Other names: Zotarolimus-eluting stent

Cypher

Device

Sirolimus-eluting stent

Other names: Sirolimus-eluting stent

Taxus Liberte

Device

Paclitaxel-eluting stent

Other names: Paclitaxel-eluting stent

Primary outcomes

  1. The composite of death (all cause-mortality), myocardial infarction, and ischemia-driven target vessel revascularization

    Time frame: at 12 months after the index procedure

Secondary outcomes

  1. All-cause Death

    Time frame: In-hospital, 30 days, 6 months, 1 year, and thereafter annually upto 5 years

  2. Cardiac death

    Time frame: In-hospital, 30 days, 6 months, 1 year, and thereafter annually upto 5 years

  3. Myocardial infarction

    Time frame: In-hospital, 30 days, 6 months, 1 year, and thereafter annually upto 5 years

  4. Target vessel revascularization (all and ischemia-driven)

    Time frame: In-hospital, 30 days, 6 months, 1 year, and thereafter annually upto 5 years

  5. Target lesion revascularization (all and ischemia-driven)

    Time frame: In-hospital, 30 days, 6 months, 1 year, and thereafter annually upto 5 years

  6. Stent thrombosis by definition of Academic Research Consortium (ARC)

    Time frame: In-hospital, 30 days, 6 months, 1 year, and thereafter annually upto 5 years

  7. Late luminal loss in both in-stent and in-segment

    Time frame: at 8 month angiographic follow-up

  8. Binary restenosis in both in-stent and in-segment

    Time frame: At 8 month angiographic follow-up

  9. Procedural success defined as achievement of a final diameter stenosis of <30% by QCA using any percutaneous method, without the occurrence of death, Q wave MI, or urgent revascularization during the hospital stay.

    Time frame: In-hospital

Sponsors and collaborators

Lead sponsor

Seung-Jung Park

Other

Collaborators

  • Medtronic Vascular

Registry information

Official study title

Comparison of the Efficacy and the Safety of Zotarolimus-Eluting Stent Versus Sirolimus-Eluting Stent and PacliTaxel-Eluting Stent for Coronary Lesions

Acronym: ZEST

Important dates

Study start
2006
Primary completion
2009
Study completion
2009
First posted
Jan 4, 2007
Registry last updated
Aug 21, 2012

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.