Manchester University NHS Foundation Trust
Manchester, M13 9WL, United Kingdom
NCT Number: NCT03501836
This study is designed to compare the performance of both 6 and 10 electrode ECGs from the handheld device with the conventional 12 lead ECG. As well as comparing the detection of atrial fibrillation, the study will also compare the detection of other heart problems and of normal heart rhythm.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Manchester, M13 9WL, United Kingdom
An Electrocardiogram (ECG) 6 electrode, wireless handheld device held on the chest is being developed to allow diagnosis of heart rhythm problems without the need for connecting electrodes to the chest, arms and legs as in a standard 10 electrode (referred to as a 12-lead) ECG measurement. A faster and simpler yet accurate method for acquiring ECG data may be useful in many healthcare settings, including screening for irregular heart rhythms such as Atrial Fibrillation (AF), which is a risk factor for stroke. The wireless 6 electrode device has an extension arm for the handset with 4 additional electrodes (also positioned on the chest) to give a full 12 lead ECG signal. This study is designed to compare the performance of both 6 and 10 electrode ECGs from the handheld device (used on the chest with the subject seated) with the conventional 12 lead ECG (used with electrodes on the chest, arms and legs with the subject lying down). As well as comparing the detection of atrial fibrillation, the study will also compare the detection of other heart problems and of normal heart rhythm. Adult patients attending the clinics at Central Manchester University Hospitals NHS Foundation Trust for an ECG assessment are eligible to participate in the study. A maximum of 500 patients will be recruited to the study in order to find the number of cases with Atrial Fibrillation required to properly compare the methods. A subset of patients with normal ECGs will have additional measurements with both methods whilst lying down, reclining at an angle and sitting upright to investigate any effects of body posture on chest based ECGs.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
We want to explore whether using 6 electrodes on the chest (as in the Rapid Rhythm Handheld 8-lead ECG device) can give the same diagnostic result to the standard 10 electrode (12-lead) ECG, which uses 6 chest electrodes plus 4 electrodes on the arms and legs.
To do this we need to compare measurements taken with the 6 electrode (8 lead) study device to those taken with the gold-standard 10 electrode (12 lead) method.
We want to find out whether the new equipment can detect the same heart rhythms as the standard method, so that ECG measurements might be made more quickly and easily in the future.
Time frame: 18 months
The percentage of ECGs where a normal control ECG is matched by a normal RR ECG.
Time frame: 18 months
The percentage of ECGs where abnormalities of the control ECG are matched by similar abnormalities of the RR ECG.
Manchester University NHS Foundation Trust
Other Gov
Performance Evaluation Study of a Six Electrode (8 Lead) Wireless Handheld ECG Recording Device With Four Lead Chest Extension Versus Conventional 12-lead ECG in Heart Patients
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05459545
Arrhythmias, Cardiac, Atrial Fibrillation
Haverhill, Massachusetts, United States
View Trial DetailsNCT05987670
Arrhythmias, Cardiac, Atrial Fibrillation
London, United Kingdom
View Trial DetailsNCT04703166
Arrhythmias, Cardiac, Atrial Fibrillation
New Orleans, Louisiana, United States
View Trial DetailsNCT05820295
Arrhythmias, Cardiac, Atrial Fibrillation
New York, United States
View Trial Details