Wireless EMG-Based Monitoring of Paraspinal Muscle Activation in Adolescent Idiopathic Scoliosis

This study aims to develop and evaluate a wireless, non-invasive, embedded electromyography (EMG) system for monitoring paraspinal muscle activation asymmetries in adolescents with idiopathic scoliosis. Surface EMG electrodes will be placed bilaterally around the apical vertebra of the spinal curve to record muscle activity during static (seated) and dynamic (trunk extension) tasks. Measurements will be taken longitudinally over the course of physiotherapy treatment to evaluate whether the recorded muscle activity patterns can serve as an objective, non-invasive indicator of treatment response, potentially reducing reliance on repeated radiographic (X-ray) follow-up.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Age range

10 year–18 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Amasya University

Amasya, 05100, Turkey (Türkiye)

Location contact

Alpaslan Ersöz, Ph.D

CONTACT

[email protected]

+905312561935

Alpaslan Ersöz, Ph.D

PRINCIPAL_INVESTIGATOR

Ertuğrul Deniz Köse, Ph.D

SUB_INVESTIGATOR

Eylem Küçük, Ph.D

SUB_INVESTIGATOR

About this study

Adolescent idiopathic scoliosis (AIS) is a three-dimensional spinal deformity typically diagnosed and monitored through radiographic assessment of the Cobb angle. While imaging remains the clinical gold standard, it involves radiation exposure and is typically performed at limited intervals, making it less suitable for frequent, short-term monitoring of treatment response. Prior research has shown that paraspinal muscle activation asymmetries - particularly increased convex-side activation near the apex of the curve - are consistently observed in AIS and may serve as early, objective markers of curve progression and treatment response, as demonstrated in prospective cohort and machine-learning-based studies.

This study will use a custom-developed, low-power, wireless, embedded surface EMG (sEMG) measurement system, consisting of skin-surface EMG electrodes, an analog front-end (AFE) for signal conditioning and digitization, and a microcontroller-based wireless communication module. EMG signals will be sampled at a minimum of 1000 Hz using a differential (bipolar) electrode configuration to minimize noise and common-mode interference.

Electrodes will be placed bilaterally on the paraspinal muscles at the level of the apical vertebra of the major spinal curve, approximately 3 cm lateral to the spinous process, oriented parallel to the muscle fibers. Standard skin preparation procedures (shaving, alcohol cleaning) will be used to reduce skin impedance prior to electrode placement.

EMG recordings will be performed under two task conditions: a static task, in which participants sit upright with hips and knees flexed at 90°, arms at their sides, and feet on the floor; and a dynamic task, in which participants perform active trunk extension in the prone position for a defined number of repetitions. These tasks are designed to capture both static postural and dynamic movement-related muscle activation patterns.

Recorded EMG signals will be processed to calculate root mean square (RMS) and mean absolute value (MAV) parameters, with frequency-domain (FFT) analysis performed as needed. Convex- and concave-side RMS values at each vertebral level will be used to derive muscle activation ratios and asymmetry indices. Measurements will be repeated at different time points over the course of physiotherapy treatment to evaluate longitudinal changes in muscle activation patterns, and associations between EMG-based indices and clinical treatment outcomes will be examined using appropriate statistical methods.

The study is being conducted in two phases: an initial technical validation phase, in which system performance is verified using commercial EMG sensor evaluation boards and microcontroller-based development platforms; and a subsequent phase in which a custom-designed wireless sEMG system (incorporating a proprietary analog front-end and embedded control unit) is evaluated for feasibility and usability in monitoring muscle activation patterns in scoliosis patients during physiotherapy. Only the human-subjects (clinical) component of this work is registered here; the underlying hardware/firmware engineering and bench validation are not within the scope of this trial record.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Diagnosed with adolescent idiopathic scoliosis
  • Cobb angle between 10° and 25°
  • No prior surgical or conservative treatment for scoliosis

Exclusion criteria

  • Neurological disease
  • Significant concomitant orthopedic problems
  • Back pain severe enough to interfere with the measurement process

Treatment and study plan

Wireless Embedded Surface EMG (sEMG) Measurement System

Device

A custom-developed, low-power, wireless, non-invasive surface EMG system consisting of skin-surface electrodes, an analog front-end (AFE) for signal conditioning and digitization, and a microcontroller-based wireless communication module. Electrodes are placed bilaterally on the paraspinal muscles at the apical vertebra level, approximately 3 cm lateral to the spinous process. EMG signals are sampled at ≥1000 Hz using a differential (bipolar) configuration and analyzed for root mean square (RMS), mean absolute value (MAV), and frequency-domain (FFT) parameters to quantify muscle activation asymmetry between the convex and concave sides of the spinal curve.

Primary outcomes

  1. Change in Paraspinal Muscle Activation Asymmetry Index

    Time frame: Baseline and through study completion, an average of 1 year

    An asymmetry index will be calculated from bilateral surface EMG RMS (root mean square) values recorded at the apical vertebra level during static and dynamic tasks, comparing convex- and concave-side paraspinal muscle activation. Change in this index over the course of treatment will be evaluated.

Secondary outcomes

  1. Correlation Between EMG-Based Muscle Activation Asymmetry Index and Clinical Treatment Outcome (Cobb Angle Change)

    Time frame: Baseline and through study completion, an average of 1 year

    The relationship between change in EMG-derived muscle activation asymmetry and change in Cobb angle (measured via standard clinical radiography) will be evaluated using appropriate correlation analysis.

  2. Device Signal Acquisition Success Rate

    Time frame: through study completion, an average of 1 year

    The proportion of EMG recording sessions in which signal quality meets predefined criteria for analysis (e.g., acceptable signal-to-noise ratio, no excessive artifact), assessing the technical feasibility of the wireless embedded measurement system in a clinical setting.

Study contacts

Contact information is provided by the study sponsor or research team.

Alpaslan Ersöz, Ph.D

CONTACT

[email protected]

+905312561935

Sponsors and collaborators

Lead sponsor

Ertugrul Deniz Kose

Other

Registry information

Official study title

Design of a Wireless and Non-Invasive EMG-Based Embedded Measurement System for Monitoring Muscle Activation Asymmetries in Scoliosis

Acronym: AIS-EMG

Important dates

Study start
2026
Primary completion
2027
Study completion
2028
First posted
Jul 31, 2026
Registry last updated
Jul 31, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.