IRCCS Istituto Auxologico Italiano
Milan, MI, 16149, Italy
NCT Number: NCT05782647
The main purpose of this study is to assess the reliability of a new patient's self-administered wearable watch-type BP monitor in detecting episodes of hypotensive (pre)syncope. Secondary aim regards the estimation of feasibility of this tool.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Milan, MI, 16149, Italy
Background While ECG monitoring is a reliable and established method that allows to document bradycardia in a substantial proportion of patients affected by cardioinhibitory reflex syncope, the documentation of a transient hypotension is only seldom achieved in patients affected by hypotensive syncope. Conventional ambulatory blood pressure (BP) monitoring (ABPM) has important limitations due to the short period of monitoring (usually 24-48 hours) and the intermittent nature of BP measurements (usually every 15-20 min).
The main purpose of this study is to assess the reliability of a new patient's self-administered wearable watch-type BP monitor in detecting episodes of hypotensive (pre)syncope. Secondary aim regards the estimation of feasibility of this tool.
Method The study is a prospective intrapatient comparison during tilt testing between BP measured by mean of a wearable watch-type BP monitor (Omron HeartGuide 6410T, Omron Healthcare, Kyoto, Japan) and by mean of the standard methods for continuous finger BP monitoring (Finometer®, Finapres Medical Systems, Enchede, The Netherlands, and Task Force® monitor, CNSystem, Graz, Austria), based on the photoplethysmographic volume clamp method .
Study design BP values observed during tilt testing baseline and at the time of impeding syncope will be measured by mean of the HeartGuide device and will be compared with the standard of reference of BP. BP will be recorded at rest at baseline, shortly after upright in tilting position (at stabilization), at the time of occurrence of impeding syncope (presyncope) or, alternatively at the time of maximum hypotensive effect, if syncope will not occur, and finally in the recovery period at the end of the test after returning in supine position.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Wearable (watch-type) monitor: HeartGuide 6410T (Omron Healthcare, Kyoto, Japan)
Time frame: 2 hours
Difference between baseline (rest) BP and BP at the presyncopal event ("Delta BP slope") during tilt testing with HeartGuide and with control
Time frame: 2 hours
Number of patients who will show failure of HeartGuide to measure BP during tilt event
Istituto Auxologico Italiano
Other
Feasibility of Blood Pressure Measurement With a Wearable (Watch-type) Monitor in Patients With Syncope
Acronym: Watch-VD
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06038708
Autonomic Nervous System Diseases, Consciousness Disorders
Bolzano, Italy
View Trial DetailsNCT05728255
Autonomic Nervous System Diseases, Cardiovascular Diseases
Marseille, France
View Trial DetailsNCT04972123
Autonomic Nervous System Diseases, Consciousness Disorders
Madison, Wisconsin, United States
View Trial DetailsNCT05729724
Ambulatory Blood Pressure Monitoring, Antihypertensive Drugs
Milan, MI, Italy
View Trial Details