Skip to main content
OpenTrials
Completed

NCT Number: NCT06434142

Wear Assessment of Novel PEEK Telescopic Attachment for Overdenture

To assess the wear of Zirconia-PEEK versus cobalt-chromium-PEEK telescopic attachments for implant retained complete mandibular overdenture. The wear of Zirconia-PEEK telescopic attachments can affect the retention of implant retained complete mandibular overdenture.

Completed

Looking for future studies?

Notify Me

Key information

Age range

50 year–70 year

Sex eligibility

Male

Study type

Interventional

Phase

Not applicable

Primary location

Hamada Zaki Mahross

Cairo, 11884, Egypt

About this study

Twelve completely edentulous patients were randomly chosen for implant retained telescopic overdentures construction and divided into two groups, where group I was a patient with zirconia copy, and group II was with cobalt chromium CoCr copy. The PEEK was constructed for both groups as a secondary coping telescopic attachment for the denture. The wear measurements of PEEK were performed optically by using a USB digital microscope with a built-in camera connected to a compatible personal computer at different intervals of baseline, 3, 6, and 9 months. The data was statistically analyzed and compared using student t-test, ANOVA, and Post Hoc Test.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • completely edentulous
  • free from any dental or systemic diseases

Exclusion criteria

  • medically ill fit patient
  • female patient

Treatment and study plan

implant overdenture

Procedure

Following the two-stage surgical protocol, two dental implant fixtures with a length of 10 mm and a diameter of 3.7 mm were inserted at the canine area of the mandibular alveolar ridge.

Primary outcomes

  1. the mean wear values

    Time frame: at baseline

    measurement of the mean of wear between two test groups

  2. the mean wear values

    Time frame: after 3 months interval

    measurement of the mean of wear between two test groups

  3. the mean wear values

    Time frame: after 6 months interval

    measurement of the mean of wear between two test groups

Sponsors and collaborators

Lead sponsor

Hamada Zaki Mahross Atia

Other

Registry information

Official study title

Wear Assessment of Novel PEEK Telescopic Attachment for Implant Retained Mandibular Overdenture

Important dates

Study start
2024
Primary completion
2024
Study completion
2024
First posted
May 30, 2024
Registry last updated
May 30, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.