Wavelight® Refractive Suite
DeviceExcimer EX500 and Femtosecond FS200 lasers (Wavelight® Refractive Suite) used during LASIK surgery for corneal flap creation and corneal ablation
NCT Number: NCT01941485
The purpose of this study is to evaluate the accuracy of the WaveLight FS200 femtosecond laser, as assessed by 1 day and 1 month post-operative optical coherence tomography (OCT) anterior segment corneal measurements compared to pre-operative flap thickness target.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Excimer EX500 and Femtosecond FS200 lasers (Wavelight® Refractive Suite) used during LASIK surgery for corneal flap creation and corneal ablation
Surgical procedure for treating refractive error based on corneal reshaping
Time frame: Day 1 Postoperative
The expected flap thickness as determined pre-operatively was subtracted from the achieved flap thickness at Day 1 postoperative as assessed by optical coherence tomography (ie, an imaging method using light to capture three-dimensional images). Accuracy of flap creation was defined as an achieved thickness within 10 microns of expected thickness.
Time frame: Operation/Surgery (Day 1)
OBL (the collection of gas bubbles during corneal flap creation) was assessed by digital photo analysis of the area covered by the flap and is reported as the percentage of participants with opaque bubble layer development during femtosecond flap creation.
Time frame: Operation/Surgery (Day 1)
The extent of OBL was assessed by digital photo analysis of the area covered by the flap and is reported as the percentage of flap with opaque bubble layer development during femtosecond flap creation.
Time frame: Month 1 Postoperative
The expected flap thickness as determined pre-operatively subtracted from the achieved flap thickness at Month 1 postoperative as assessed by optical coherence tomography (ie, an imaging method using light to capture three-dimensional images). Accuracy of flap creation was defined as an achieved thickness within 10 microns of expected thickness.
Time frame: Baseline/Screening (Day 0), Day 1 Postoperative, Month 1 Postoperative, Month 3 Postoperative, Month 6 Postoperative, Month 12 Postoperative
Visual acuity (VA) without spectacles or other visual corrective devices, was performed with an Early Treatment Diabetic Retinopathy Study (ETDRS) chart set at a distance of 4 meters. UCVA was measured in logMAR (logarithm of the minimum angle of resolution), with 0.00 logMAR corresponding to 20/20 Snellen. A lower logMAR value indicates better visual acuity.
Time frame: Baseline/Screening (Day 0), Day 1 Postoperative, Month 1 Postoperative, Month 3 Postoperative, Month 6 Postoperative, Month 12 Postoperative
VA with the subjects's best spectacles or other visual corrective devices, was performed with an ETDRS chart set at a distance of 4 meters. BCVA was measured in logMAR (logarithm of the minimum angle of resolution), with 0.00 logMAR corresponding to 20/20 Snellen. A lower logMAR value indicates better visual acuity.
Time frame: Baseline/Screening (Day 0), Day 1 Postoperative, Month 1 Postoperative, Month 3 Postoperative, Month 6 Postoperative, Month 12 Postoperative
A series of test lenses in graded powers was used to determine which corrective lenses provided the sharpest, clearest vision. Manifest refraction is measured in diopters. Each eye contributed individually to the analysis.
Time frame: Baseline/Screening (Day 0), Month 1 Postoperative, Month 3 Postoperative, Month 6 Postoperative, Month 12 Postoperative
A series of test lenses in graded powers was used to determine which corrective lenses provided the sharpest, clearest vision. Manifest refraction is measured in diopters. Each eye contributed individually to the analysis.
Time frame: Baseline/Screening (Day 0), Month 1 Postoperative, Month 3 Postoperative, Month 6 Postoperative, Month 12 Postoperative
Contrast sensitivity (ie, the ability to detect slight changes in luminance before they become indistinguishable) was assessed binocularly with distance manifest correction in place and uncorrected. Contrast sensitivity was assessed at spatial frequencies of 3, 6, 12, and 18 cycles per degree (cpd), where 3.0 cpd = A, 6.0 cpd = B, 12.0 cpd = C, and 18.0 cpd = D. Raw scores were log transformed. A higher numeric value represents better contrast sensitivity. Both eyes contributed to the analysis.
Time frame: Operation/Surgery (Day 1), Day 1 Postoperative, Month 1 Postoperative, Month 3 Postoperative, Month 6 Postoperative, Month 12 Postoperative
The diameter of the corneal flap was assessed by OCT (ie. an imaging method using light to capture three-dimensional images). Corneal flap is measured in millimeters.
Time frame: Operation/Surgery (Day 1), Month 1 Postoperative, Month 6 Postoperative, Month 12 Postoperative
Wavefront aberrations (optical imperfections of the eye that prevent light from focusing perfectly on the retina, resulting in defects in the visual image) were measured using a commercially available system. Higher order aberrations (i.e., spherical aberrations, coma, and trefoil) are defined as optical imperfections which cannot be corrected by any reliable means of present technology.
Time frame: Baseline/Screening (Day 0), Month 1 Postoperative, Month 6 Postoperative, Month 12 Postoperative
As recorded by the subject on the the Refractive Status and Vision Profile (RSVP), a self-reported questionnaire used to measure vision-related health status in persons with refractive error, on a scale from 0 (completely blind) to 10 (perfect vision).
Time frame: Baseline/Screening (Day 0), Month 1 Postoperative, Month 6 Postoperative, Month 12 Postoperative
As recorded by the subject on the the Refractive Status and Vision Profile (RSVP), a self-reported questionnaire used to measure vision-related health status in persons with refractive error.
Time frame: Baseline/Screening (Day 0), Month 1 Postoperative, Month 6 Postoperative, Month 12 Postoperative
As recorded by the subject on the RSVP questionnaire
Time frame: Baseline/Screening (Day 0), Month 1 Postoperative, Month 6 Postoperative, Month 12 Postoperative
As recorded by the subject on the RSVP questionnaire
Time frame: Baseline/Screening (Day 0), Month 1 Postoperative, Month 6 Postoperative, Month 12 Postoperative
As recorded by the subject on the RSVP questionnaire, where 0 is "Not applicable", 1 is "No difficulty at all", 2 is "A little difficulty", 3 is "Moderate difficulty", 4 is "Severe difficulty" and 5 is "So much difficulty that I did not do the activity with this alternative".
Time frame: Baseline/Screening (Day 0), 1 Month Postoperative, Month 3 Postoperative, Month 6 Postoperative, Month 12 Postoperative
Corneal curvature as assessed by a commercially available system and measured in diopters.
Time frame: Operation/Surgery (Day 1)
The time to create the flap with FS200 Femtosecond Flap Creation System, measured in seconds.
Time frame: Day 1 Postoperative, Month 1 Postoperative, Month 3 Postoperative, Month 6 Postoperative, Month 12 Postoperative
The Q-value (a measure of corneal asphericity) was assessed using a commercially available system. The Q-values are negative (-1 < Q < 0) for prolate corneas, in which the central curvature is steeper than the peripheral curvature, and positive (Q > 0) for oblate corneas, in which the central curvature is flatter than the peripheral curvature.
Time frame: Day 1 Postoperative, Month 1 Postoperative, Month 3 Postoperative, Month 6 Postoperative, Month 12 Postoperative
The AC volume (a measure of the shallowness of the anterior chamber) was assessed using a commercially available system. The lower the chamber volume, the more shallow the anterior chamber or the chamber angle.
Time frame: Day 1 Postoperative, Month 1 Postoperative, Month 3 Postoperative, Month 6 Postoperative, Month 12 Postoperative
The AC depth (axial distance between the anterior surface of the cornea and the anterior surface of the lens) was assessed using a commercially available system. A higher value represents a longer distance.
Time frame: Day 1 Postoperative, Month 1 Postoperative, Month 3 Postoperative, Month 6 Postoperative, Month 12 Postoperative
The angles (angular measurement of the space between the iris and the lens) were assessed using a commercially available system. The higher the value, the bigger the space.
Alcon Research
Industry
A Prospective, Global, Multi-Center Study to Evaluate Longitudinal Flap Accuracy on Subjects Undergoing Myopic Refractive Surgery Using the WaveLight® Refractive Suite
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT01941498
Astigmatism, Eye Diseases
View Trial DetailsNCT01912768
Astigmatism, Eye Diseases
View Trial DetailsNCT01912781
Astigmatism, Eye Diseases
View Trial DetailsNCT01699750
Astigmatism, Eye Diseases
Fort Worth, Texas, United States
View Trial Details