Rehabilitation Institute of Chicago
Chicago, Illinois, 60611, United States
NCT Number: NCT03222505
The goal of this research study was to examine the immediate effects of a prototype wearable robotic stride management assist device (SMA) designed by Honda R&D® on clinical walking performance, walking energetics, gait kinematics and corticospinal excitability in individuals with stroke.
Looking for future studies?
Notify Me18 year–75 year
All sexes
Interventional
Not applicable
Chicago, Illinois, 60611, United States
The goal of this research study was to examine the immediate effectiveness of a prototype wearable robotic stride management assist device (SMA) designed by Honda R&D on clinical walking performance, walking energetics, gait kinematics and corticospinal excitability in individuals with stroke.
The SMA assists walking by providing a flexion and extension torque assist at the hip joint. The subjects in this study are asked to perform two sets of experiments: one set with the device on and one set with the device turned off. The order in which the subjects performed these sets of experiments is selected randomly. Each set of experiments includes over-ground walking speed and endurance tests, a graded treadmill test with metabolic measures, motion capture and force treadmill analysis, and measures of corticospinal drive using transcranial magnetic stimulation (TMS). The primary outcome to be measured is change in self-selected walking speed with the device on, the secondary outcome measures include metabolic, corticospinal and biomechanical analysis.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
-
Exclusion criteria
Subjects performed assessments of walking and motor performance while wearing the Honda Stride Assist Device.
Subjects performed assessments of walking and motor performance without wearing the Honda Assist Device.
Time frame: Day 1
The 6 Minute Walk Test (6MWT) is a test of endurance, by measuring the distance a subject can walk indoors on a flat, hard surface in a period of 6 minutes, using assistive devices, as necessary.The distance is measured with a measuring wheel. The instructions are "Walk covering as much ground as you can in 6 min. You can stop to sit or stand if needed."
Time frame: Day 1
Peak treadmill (TM) velocity: subjects walked on motorized treadmill with harness but no Body Weight Support (BWS). Testing started at 0.5 km/h and was increased in 0.5 km/h increments every 3 minutes until peak TM speed was achieved (identified as ability to sustain speed for ≥1min without stopping the treadmill).
Time frame: Day 1
TMS measurements will involve generating motor evoked potentials (MEP) for each muscle from two different coil positions - 2cm on either side of the vertex. Motor evoked potentials (MEPs) at intensities ranging from 70 - 140% active threshold will be generated for each muscle from each coil position. TMS is a safe, non-invasive, painless method of brain stimulation that has been widely used to study the physiology of the representations of muscles in the motor cortex in healthy and neurologically disordered individuals. A positive percent change in excitability indicates higher excitability in the device-on condition. A negative percent change in excitability indicates higher excitability in the device-off condition.
Time frame: Day 1
TMS measurements will involve generating motor evoked potentials (MEP) for each muscle from two different coil positions - 2cm on either side of the vertex. Motor evoked potentials (MEPs) at intensities ranging from 70 - 140% active threshold will be generated for each muscle from each coil position. TMS is a safe, non-invasive, painless method of brain stimulation that has been widely used to study the physiology of the representations of muscles in the motor cortex in healthy and neurologically disordered individuals. A positive percent change in excitability indicates higher excitability in the device-on condition. A negative percent change in excitability indicates higher excitability in the device-off condition.
Shirley Ryan AbilityLab
Other
Development of Walk Assist Device to Improve Community Ambulation
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02425345
Arterial Occlusive Diseases, Arteriosclerosis
View Trial DetailsNCT05589402
Bone Diseases, Brain Diseases
Harlingen, Texas, United States
View Trial DetailsNCT06750692
Brain Diseases, Cardiovascular Diseases
Afyonkarahisar, Turkey (Türkiye)
View Trial DetailsNCT04992195
Alzheimer Disease, Arterial Thromboembolism
Hong Kong
View Trial Details