Peking University Third Hospital
Beijing, Beijing Municipality, 010, China
NCT Number: NCT04955483
1. Compare the effect of virtual single energy imaging and virtual single energy combined with MAR technology to remove metal artifacts in the spine. 2. Discuss the most suitable KeV of virtual single energy imaging combined with MAR technology to remove metal artifacts.
Looking for future studies?
Notify MeAll sexes
Observational
Beijing, Beijing Municipality, 010, China
The virtual single-energy imaging of energy spectrum CT combined with the metal artifact reduction technology MARS Multi Artifact Reduction System] can effectively reduce the interference of metal artifacts. This is because MAR technology corrects the image through an iterative algorithm, improves the spatial resolution, and restores the details of the adjacent tissue of the metal object. Virtual single-energy imaging technology can effectively reduce hardening artifacts. The two are used in combination to achieve the purpose of reducing metal artifacts. There have been articles about virtual single energy combined with MAR technology to reduce metal artifacts. However, the current researches mostly focus on the comparison of virtual single energy combined with MAR technology and conventional CT examination and virtual single energy imaging. There are few evaluations on the severity of metal artifacts after spinal surgery. According to different surgical methods, metal The difference in the number of implants will result in different artifact reduction effects. Secondly, the current research on the suitable KeV of virtual single energy combined with MAR technology to reduce metal artifacts is less discussed and reported.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
combined with MAR reconstruction group
Time frame: 2019.2.1-2019.2.15
Select the largest level of artifacts in the image, place a region of interest (ROI) with an area of 100-150mm2 in the soft tissue around the metal and spinal canal for CT value and standard deviation (SD) measurement, avoid the boundary area, and measure the ROI area Artifact Index ASelect the largest level of artifacts in the image, place a region of interest (ROI) with an area of 100-150mm2 in the soft tissue around the metal and spinal canal for CT value and standard deviation (SD) measurement, avoid the boundary area, and measure the ROI area Artifact Index AI
Peking University Third Hospital
Other
A Comparative Study of Virtual Single-energy Imaging and De-metallic Artifact Technology in Reducing Spinal Metallic Artifacts
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06393530
Bone Diseases, Musculoskeletal Diseases
Poznan, Poznań, Poland
View Trial DetailsNCT04877470
Bone Diseases, Characteristics Disease
Heerlen, Limburg, Netherlands
View Trial DetailsNCT04545983
Bone Diseases, Cervical Myelopathy
Heerlen, Limburg, Netherlands
View Trial DetailsNCT04642625
Anesthesia, Local, Anesthesia, Regional
Edirne, Centrum, Turkey (Türkiye)
View Trial Details