Skip to main content
OpenTrials
Completed

NCT Number: NCT05551715

Virtual Eye Model System for Personalised Refractive Surgery Treatment

Justification: Although great strides have been made in the past to develop VEMoS software, it has not yet been validated with actual clinical data from patients who have undergone cataract or refractive surgery.

There are some fundamental questions that must be addressed to validate and update the software, such as the objective visual quality metrics that best predict the patient's post-surgical subjective vision from the predictions of the optical properties of the eye.

The VEMoS software must be adjusted for different types of inputs and eye parameters:

Corneal tomography of MS39-AXL MS39-AXL corneal tomography + biometric data from the IOL Master MS39-AXL corneal tomography + IOL Master biometric data + total aberrometry Combinations of any of the above with the optical properties of a specific IOL, etc.

Objective The main objective is to standardize the selection of parameters to personalize refractive surgery, based on the biometric data of each patient.

The objectives necessary to achieve such an ambitious goal are:

1. Redesign VEMoS software 2. Determine which biometric data, diagnostic tools, and objective and subjective metrics of visual quality are best for the selection of optimal refractive parameters for surgery 3. Optimize the combined use of biometric data, VEMoS software, and visual quality metrics Study design The proposed multicenter clinical trial is observational and prospective. There will be three arms within the clinical trial, a no-treatment arm, a refractive surgery arm, and a cataract surgery arm. Participants in the untreated arm will undergo an ophthalmic exam only once. Participants in the other two arms will undergo two ophthalmic exams, one before and one after surgery. For all participants, cataract or refractive surgery will be performed as part of routine clinical practice. Other additional tests performed are all non-invasive.

Study population Untreated eye arm patients 18 to 40 years of age. Refractive surgery arm patients who are planned and have consented to a corneal refractive procedure to gain spectacle independence.

Cataract surgery arm patients older than 50 years who are planned and have consented to cataract surgery.

Sample size The sample sizes for each arm of the clinical trial are as follows.

Untreated eye arm:

The goal is to recruit 600 eyes from 300 patients, 100 patients in each of these groups:

Myopia (from -10 D to -0.75 D) Emmetropia (from -0.5 D to + 0.5 D) Hyperopia (from 0.75 D to 5 D)

Refractive surgery arm:

For LASIK, the goal is to recruit 800 eyes from 400 patients, 100 patients in each of these groups:

High myopia (from -10 D to -6 D) Medium myopia (from -6 D to -3 D) Low myopia (from -3 D to -1 D) Hyperopia (from +1 D to +4 D)

For SMILE, the goal is to recruit 400 eyes from 200 patients, 100 patients in each of these groups:

High myopia (from -10 D to -6 D) Average myopia (from -6 D to -3 D)

For the cataract surgery arm:

The goal is to recruit 400 eyes from 200 patients, 100 patients in each of these groups Zeiss monofocal IOLs multifocal IOL

A total of 500 patients are expected between the Vissum, IMO and IOA clinics in Miranza.

A total of 250 patients are expected between hospital and university of Coimbra epe (Portugal).

A total of 350 patients are expected at Aarhus universitetshospital (Denmark).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Alicante Vissum Miranza

Alicante, 03016, Spain

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

For the untreated eyes arm, the inclusion criterion is:

  • patients from 18 to 40 years of age and with less than 2 D of astigmatism.

For the refractive surgery arm, the inclusion criteria are:

  • for LASIK: sphere between -10 D and +4 D and with less than 3 D of astigmatism.
  • for SMILE: sphere between -10 D and -3 D, with less than 3 D of astigmatism.

For the cataract surgery arm, the inclusion criterion is:

  • patients older than 50 years old without any active ocular pathologies affecting visual capabilities except cataract and with less than 1 D of astigmatism.

Exclusion criteria

For the untreated eyes and the refractive surgery arms, the exclusion criteria are:

  • ocular pathology affecting visual capabilities,
  • reduced transparency of ocular media,
  • systemic disease affecting visual capabilities.

For the cataract surgery arms, the exclusion criterion is:

  • Systemic disease affecting visual capabilities.
  • Ocular pathology affecting visual capabilities other than cataract
  • Included patients will be excluded if surgical complications occurs

Treatment and study plan

Software development for individualized refractive surgery

Device

Software development for individualized refractive surgery

Primary outcomes

  1. Variables to run the VEMoS software and obtain estimates and simulations Corneal Topography

    Time frame: 3 months

    To evaluate the keratomery in diopters

  2. Variables to run the VEMoS software and obtain estimates and simulations Pupil size

    Time frame: 3 months

    To evaluate pupil size at different illumination in milimeters

  3. Variables to run the VEMoS software and obtain estimates and simulations anterior chamber depth

    Time frame: 3 months

    To obtain the anterior chamber depth in milimeters

  4. Variables to run the VEMoS software and obtain estimates and simulations, crystalline lens thickness

    Time frame: 3 months

    To obtain the crystalline lens thickness in milimeters

  5. Variables to run the VEMoS software and obtain estimates and simulations, axial length

    Time frame: 3 months

    To obtain the axial length in milimeters

Sponsors and collaborators

Lead sponsor

Vissum, Instituto Oftalmológico de Alicante

Other

Collaborators

  • Aarhus University Hospital
  • COSTRUZIONI STRUMENTI OFTALMICI C.S.O. SRL
  • Unidade Local de Saúde de Coimbra, EPE

Registry information

Important dates

Study start
2022
Primary completion
2024
Study completion
2024
First posted
Sep 23, 2022
Registry last updated
Sep 22, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.