Modified Ambu Spur II bag valve mask
DeviceSubjects deliver breaths to manikin (IngMar RespiTrainer manikin model) a modified Ambu Spur II bag valve mask with a supplemental external handle
NCT Number: NCT02800213
Investigators compared tidal volumes for single rescuer ventilation using a modified bag valve mask with a supplemental external handle versus a conventional bag valve mask in a manikin model.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Not applicable
This was a prospective, randomized, crossover study to assess the tidal volume delivered using a standard and modified bag valve mask (BVM) device in a manikin airway model. The modified device comprised a standard bag valve mask with supplemental external bar. Data was collected during May 2016 at the San Antonio Military Medical Center. Emergency medicine providers (physicians, physician assistants, residents, nurses, medics) were randomized to device order. Prior to participation each participant filled out a survey indicating their job status, gender, years of medical experience, and experience level with BVM ventilation. Hand grip strength and size (length, width, span) were measured. Each participant was then asked to provide BVM ventilation using the assigned devices at a rate of 10 breaths per minute for 3 minutes for a total of 30 breaths. Tidal volume of each delivered breath was recorded in milliliters. After a 3 minute rest period, testing was repeated with the second device. After ventilation with each device, participants completed an anonymous questionnaire that used a Likert scale to assess perceived qualities of the modified device including ease of use, ability to provide a superior mask seal, willingness to use in an emergency situation, and overall preference between the two devices. Each participant served as his/her own control.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Subjects deliver breaths to manikin (IngMar RespiTrainer manikin model) a modified Ambu Spur II bag valve mask with a supplemental external handle
Subjects deliver breaths to manikin (IngMar RespiTrainer manikin model) a conventional Ambu Spur II bag valve mask
Time frame: 3 minutes
Mean received tidal volume for 30 breaths delivered by the subjects over three minutes as measured via the RespiTrainer Advance manikin model monitor output.
Brooke Army Medical Center
Fed
Single Rescuer Ventilation Using a Bag Valve Mask With Supplemental External Handle Versus Standard Bag Valve Mask in a Manikin Model: A Randomized Crossover Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04950894
Apnea, Apnea+Hypopnea
Birmingham, Alabama, United States
View Trial DetailsNCT02083952
Apnea, Arrhythmias, Cardiac
Ridgewood, New Jersey, United States
View Trial DetailsNCT07604428
Apnea, Eye Diseases
Olomouc, Czechia
View Trial DetailsNCT05302219
Apnea, Circulatory; Change
Kladno, Czechia
View Trial Details