University of Wisconsin Madison
Madison, Wisconsin, 53726, United States
NCT Number: NCT03552133
The purpose of this pilot study is to determine the feasibility of using a novel treatment for sleep apnea in which the patient's own exhaled CO2 is tightly controlled and used in a rebreathe system to reduce sleep disordered breathing.
Looking for future studies?
Notify Me18 year–75 year
All sexes
Interventional
Not applicable
Madison, Wisconsin, 53726, United States
Obstructive sleep apnea (OSA) needs to be treated with devices that will be utilized with greater compliance by patients than is currently the case with positive airway pressure. To this end, the investigators recently showed that increased inspired CO2 via rebreathing was effective in reducing most obstructive and central apneas in OSA patients. Then, the investigator's University of Wisconsin (UW) team of bioengineers, physiologists, and sleep physicians built a novel variable dead space rebreathe device-with no added positive pressure-which monitors breath by breath ventilation and automatically adjusts the rebreathe dead space volume to add or subtract the level of inspired CO2 depending on the degree of sleep disordered breathing. This approach provides the minimum effective CO2 dose needed in individual OSA patients to stabilize central respiratory motor output and to recruit upper airway dilator muscles, thereby treating obstructive and central apneas. The investigators propose to determine the effectiveness of this "Smart CO2" treatment as well as its effects on sleep state stability, sleep quality, and blood pressure in 10 moderate to severe OSA patients studied over several nights. The investigators expect the findings from the proposed study to be sufficient to determine if the "Smart CO2" treatment is a viable approach to OSA treatment worthy of testing in a clinical trial.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
A lightweight, cylindrical reservoir attached to a face mask which monitors breathing breath-by-breath and automatically adjusts the level of dead space rebreathe volume so that CO2 will be increased and sleep apnea treated.
Time frame: three to six weeks
To determine the effects of a novel, adjustable CO2 rebreathing device on the occurrence of sleep apnea (AHI) in patients with moderate to severe obstructive sleep apnea.
Time frame: three to six weeks
To determine the effects of a novel, adjustable CO2 rebreathing device on the occurrence of sleep apnea (Arousal Index) in patients with moderate to severe obstructive sleep apnea.
Time frame: Three to six weeks
To determine whether this novel treatment influences sleep state stability following sleep.
Time frame: Three to six weeks
To determine whether this novel treatment influences systolic or diastolic blood pressure following sleep.
University of Wisconsin, Madison
Other
Feasibility of a Variable Carbon Dioxide (CO2) Rebreathe Device ("Smart CO2") to Treat Obstructive Sleep Apnea
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00811668
Apnea, Cardiovascular Diseases
View Trial DetailsNCT04671342
Apnea, Dyssomnias
Birmingham, Alabama, United States
View Trial DetailsNCT04926077
Apnea, Dyssomnias
Baltimore, Maryland, United States
View Trial DetailsNCT00823134
Apnea, Dyssomnias
Wangen, Baden-Wurttemberg, Germany
View Trial Details