Skip to main content
OpenTrials
Completed

NCT Number: NCT01471873

Variability of Pentacam-derived Back Elevation Measurements in Keratoconus and Cross-linked Corneas

Primary objective of this study was to assess the intrasession, intersession and interobserver variability of the Pentacam-derived posterior corneal elevation measurements in keratoconus eyes and eyes that underwent Corneal Collagen Cross-liknking (CxL) treatment due to progressive keratoconus.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Eye Institute of Thrace (EIT)

Alexandroupoli, Thrace, 67100, Greece

About this study

The Pentacam Classic (Oculus Optikgerate GmbH, Heidelberg, Germany, software version 1.14r04) was used for the sake of the study.Two study groups were formed: 1) Keratoconus group (KC) included patients with progressive keratoconus and 2) Collagen-Cross-linking group (CXL) included keratoconus patients that had been treated with uneventful CXL at least on year prior to their enrollment in the study.

Three consecutive scans were obtained by two experienced operators. The same procedure was repeated within two weeks for the assessment of intersession variability. In all cases acceptable maps had at least 10.0mm of corneal coverage.All back elevation points were codified in order to facilitate statistical processing of data. Further to single point analysis, three additional parameters were evaluated: a) zone 4 parameter (z4) which derived by the analysis of all points at the central 4.0mm diameter zone, b) zone 8 parameter (z8) which derived by the analysis of all points at the central 8.0mm diameter zone, and, c) highest elevation point parameter (HEP), which derived by the analysis of the highest elevation points for all participants. Reproducibility of measurements was evaluated by means of intraclass correlation coefficients (ICC). Three different ICC types were calculated: a) intrasession ICC for both operators (ICC1 & ICC2), b) interobserver ICC, and, c) intersession ICC. Moreover, Bland-Altman plots were used to evaluate the level of agreement between the two operators.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Progressive keratoconus (Keratoconus group)
  • Corneal collagen cross linking (CxL) treatment at least one year prior to enrollment (CxL group)

Exclusion criteria

  • Glaucoma
  • Suspicion of glaucoma
  • history of herpetic keratitis
  • corneal scarring
  • severe eye dryness
  • pregnancy or nursing
  • current corneal infection
  • underlying autoimmune disease

Treatment and study plan

Corneal Collagen Cross-Linking (CxL)

Procedure

The same surgical procedure was applied to all CXLG patients that included:

Instillation of proparacaine hydrochloride 0.5% drops for topical anaesthesia, application of a sponge saturated with 10% alcohol to the central cornea for 20-30 seconds and subsequent de-epithelialization by means of a hockey knife. Following de-epithelialization, a mixture of 0.1% riboflavin in 20% Dextran solution was instilled to the cornea for 30 minutes (2 drops every 2 minutes) prior to the irradiation. In details, an 8.0mm diameter of central cornea was irradiated for 30 minutes by UVA light with a wavelength of 370nm and an irradiance of 3mW/cm2.The UVA radiation source that was used is the UV-XTM (IROC AG, Zurich, Switzerland). Instillation of riboflavin drops (1 drop every 2 minutes) was continued during irradiation, as well.

Primary outcomes

  1. Variability of posterior corneal surface elevation measurements within and between sessions and within and between observers.

    Time frame: 2 weeks

    The Pentacam Classic (Oculus Optikgerate GmbH, Heidelberg, Germany, software version 1.14r04) was used for the sake of the study. Three consecutive scans were obtained by two experienced operators for the assessment of intrasession and interobserver variability. The same procedure was repeated within two weeks for the assessment of intersession variability.Bland-Altman plots were used to evaluate agreement between the 2 operators. The reproducibility of all measurements was evaluated by means of the intraclass correlation coefficient(ICC).

Sponsors and collaborators

Lead sponsor

Democritus University of Thrace

Other

Registry information

Important dates

Study start
2011
Primary completion
2011
Study completion
2011
First posted
Nov 16, 2011
Registry last updated
Jan 18, 2017

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.