Huapeng Yu
Guangzhou, Guangdong, China
NCT Number: NCT03573284
The aim of the research is to evaluate the clinical value of fractional exhaled nitric oxide(FeNO) ,impulse oscillometry(IOS) and mid-expiratory flow (MEF) in patients with cough variant asthma.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Not applicable
Guangzhou, Guangdong, China
The present study has the following objectives:
to evaluate the relationship between BHR and mid-expiratory flow, to assess the diagnostic accuracy of fractional exhaled nitric oxide,impulse oscillometry and mid-expiratory flow in CVA with special regard to its discriminating value between CVA and other causes of a chronic cough, to estimate prognostic value of BHR and fractional exhaled nitric oxide (FeNO) count in predicting response to asthma treatment.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
age 18-65 years old. Cough as the sole or predominant symptom lasting for at least 8 weeks, with no radiographic evidence of lung diseases.
Exclusion criteria
treatment of any oral corticosteroid in the last 4 weeks, and respiratory tract infection within 8 weeks.
smoking (min. 6 months) had asthma or other lung diseases, including obliterative bronchiolitis, bronchiectasis,and cystic fibrosis.
FeNO level was evaluated according to the American Thoracic Society (ATS)/ERS recommendations using a NIOX MINO analyzer (Aerocrine, Solna, Sweden) .Subjects were informed to deeply inhale NO-free air and immediately exhale in full via a mouthpiece at a constant flow rate (50 ml/s) for 10s.
The patient take seats, body relax, make sure the mouthpiece is fully covered by mouth, then clip nose with both hands to cover both sides of the cheek, and then calm breathing 1 minutes, the computer is automatically collected data calculation and print out the measurement results.
Time frame: at least 4 weeks of treatment
FENO will be performed by using a hand-held portable machine (NIOX MINO, Aerocrine AB, Solna, Sweden) at a standard flow rate of 50 mL/s, in accordance with ATS/ERS recommendations.
Time frame: at least 4 weeks of treatment
R5-R20(respiratory resistance)is measure by Jaeger MasterScreen Pulmonary
Time frame: at least 4 weeks of treatment
MMEF will be performed with a spirometer (Jaeger, Hoechberg, Germany) in accordance with the specifications and performance criteria recommended in the American Thoracic Society (ATS)/European Respiratory Society (ERS) Standardization of Spirometry
Time frame: at least 4 weeks of treatment
MCH bronchial provocation tests will be performed with the Jaeger APS Pro system.Provocative dose causing a 20% fall in FEV1(PD20) will be recorded, and BHR is defined as present if PD20≤0.48 mg. FENO is measure by a hand-held portable machine(NIOX MINO, Aerocrine AB, Solna, Sweden)
Time frame: at least 4 weeks of treatment
BHR is measure by Jaeger APS Pro system.MMEF will be performed with a spirometer (Jaeger, Hoechberg, Germany)
Zhujiang Hospital
Other
Evaluating the Efficacy of Fractional Exhaled Nitric Oxide and Impulse Oscillometry in Patients With Cough Variant Asthma
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03363698
Allergic Rhinitis, Asthma
Warsaw, Masovian Voivodeship, Poland
View Trial DetailsNCT04203472
Asthma, Bronchial Diseases
Warsaw, Poland
View Trial DetailsNCT01064245
Asthma, Bronchial Diseases
Kingston, Ontario, Canada
View Trial DetailsNCT00660114
Asthma, Bronchial Diseases
Hefei, Anhui, China
View Trial Details