Skip to main content
OpenTrials
Completed

NCT Number: NCT05137951

Validity and Reliability of Rebee Sensor to Measure Knee ROM

This study was conducted to investigate:

The criterion related validity of Rebee wearable sensor in measuring active flexion and extension of knee joint ROM compared with digital goniometer measurement.

The intra-rater reliability of Rebee wearable sensor in measuring active flexion and extension of knee joint ROM compared with digital goniometer measurement.

Completed

Looking for future studies?

Notify Me

Key information

Age range

30 year–45 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Pharos university at alexandria

Alexandria, 21500, Egypt

About this study

Range of Motion (ROM) of the joint is one of the factors that determine function of the musculoskeletal system. This parameter should be measured and recorded by a valid and reliable method . It is considered to be an essential component of lower limb physical examination, which can be applied using various instruments such as goniometers and inclinometers .

Range of motion of the knee joint is one of the major factors determining the outcome after knee injuries. It is also an important measurement required by many knee scoring systems to determine the preoperative status and postoperative outcome .

Measurements are used by physical therapists to quantify limitations of motion, it used to decide an appropriate therapeutic interventions and document the effectiveness of these interventions. The ideal measuring device should give reproducible valid and reliable data .It is required an essential skill in the musculoskeletal assessments commonly performed by physiotherapists.

Two-arm digital goniometer is still widely used in measuring uniaxial ROM of the joint of extremity, there is high validity, intra- rater and inter-rater reliability of the digital goniometer. It is considered valid and reliable tool that simplify physical therapists' work .The digital goniometer is the most commonly utilized clinical tool for measuring joint range of motion, the evolution of sensors technology and applications are easy to use, relatively inexpensive, and highly accessible .

Rebee is a wearable motion sensor package of sensor with its own mobile application, which measures range of joint movement in different planes easily which the patient able to wear the sensor and move easily to measure ROM and record the measurement at the application software, that is facilitate the tele-measurement which the patients are supposed to put on the sensors and perform the actions themselves, or with assistance from physical therapist.

There is lack in the literature about using Rebee wearable sensor in measuring the range of knee joint so this study was conducted to test the criterion related validity and intrarater reliability of the rebee wearable sensor in measuring active knee joint ROM compared with digital goniometer measurement.

Who can participate

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Forty normal participant's age ranged from 30 to 45.
  • The participant from both sex.
  • Participant Body mass index (BMI) from (19 to 25) normal weight (BMI= weight (kg) / [height (m)] 2)

Treatment and study plan

Rebee sensor

Device

Rebee is a wearable motion sensor package of sensor with its own mobile application, which measures range of joint movement in different planes easily which the patient able to wear the sensor and move easily to measure ROM and record the measurement at the application software Digital goniometer Goniometry has been described as a tool to measure angle. It gives the physician a useful method to diagnose musculoskeletal function in terms of ROM, monitor the progress of an intervention, record the data for future follow-up, and meet statutory and legal requirements for impairment rating and disability determinations where applicable

Other names: Digital goniometer

Primary outcomes

  1. test Validation of rebee wearable sensor for measuring knee Range of motion

    Time frame: day 1

    The criterion related validity andof Rebee wearable sensor in measuring active flexion and extension of knee joint ROM compared with digital goniometer measurement.

  2. test intrarater reliability of rebee wearable sensor to measure active knee flexion and extension ROM

    Time frame: day 1

    the procedures was repeated two times with one week interval between measurements. Researcher was recorded all the measurement.

Sponsors and collaborators

Lead sponsor

Cairo University

Other

Registry information

Official study title

Validity and Reliability of Rebee Wearable Sensor to Measure Knee Joint Range of Motion

Important dates

Study start
2021
Primary completion
2021
Study completion
2021
First posted
Nov 30, 2021
Registry last updated
Dec 13, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.