Validation of Two Wrist-worn Devices for the Assessment of Energy Expenditure in Cardiac Patients.

Improving physical activity is a core component of secondary prevention and cardiac (tele)rehabilitation. Commercially available activity trackers are frequently used to monitor and promote physical activity in cardiac patients. However studies on the validity of these devices in cardiac patients are scarce. The aim of this study is to determine the accuracy and responsiveness of two wrist-worn activity trackers, Fitbit Charge 2 (FC2) and Mio Slice (MS), for the assessment of energy expenditure (EE) in cardiac patients.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Máxima Medical Centre

Veldhoven, North Brabant, 5504 DB, Netherlands

About this study

Introduction

Improving physical activity is a core component of secondary prevention and cardiac (tele)rehabilitation. Commercially available activity trackers are frequently used to monitor and promote physical activity in cardiac patients. However studies on the validity of these devices in cardiac patients are scarce. The aim of this study is to determine the accuracy and responsiveness of two wrist-worn activity trackers, Fitbit Charge 2 (FC2) and Mio Slice (MS), for the assessment of energy expenditure (EE) in cardiac patients.

Methods

Eligible patients are recruited by their cardiologist in the outpatient cardiology clinic. If a patient is willing to participate, he/she visits the Máxima Medical Centre once, to perform the study measurements.

EE assessed by both activity trackers is compared with indirect calorimetry (Oxycon Mobile) during a laboratory activity protocol consisting of 14 low-to-moderate intensity activities. The duration of the activities varies between 1 to 5 minutes, while total duration of the protocol is 39 minutes (resting time excluded) Two groups are assessed: patients with stable coronary artery disease (CAD) and patients with heart failure with reduced ejection fraction (HFrEF).

Sample size calculation

To achieve 80% power to detect an intraclass correlation coefficient (ICC) of 0.75 (excellent agreement) under the alternative hypothesis that the ICC is 0.35 (poor agreement), a sample size of 19 subjects per study group (i.e. CAD and HFrEF) is calculated.

Statistical analysis

Accuracy of FC2 and MS will be assessed by calculating mean EE and mean differences in EE compared to the criterion measure (Oxycon Mobile). To identify if agreement is between reasonable limits one-sample T-tests will be performed using mean differences. In addition, Bland-Altman plots will be created to illustrate the level of agreement with mean bias and 95% upper and lower limits of agreement (LoA). Moreover ICC using two-way mixed models with absolute agreement will used. Responsiveness of FC2 and MS will be assessed by using a paired T-test during walking and cycling at different intensities. Significance level will be set at p<0.05 for all analyses.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

heart failure patients:

  • Patients with heart failure with reduced ejection fraction (LVEF < 40%) due to ischemic or dilating cardiomyopathy
  • New York Heart Association Class II to III
  • Speaking Dutch language

Exclusion criteria

heart failure patients:

  • Hemodynamically significant valvular disease
  • Atrial fibrillation
  • Peripheral vascular, neurological and orthopaedic conditions impairing exercise capacity
  • Severe psychological or cognitive impairments

Inclusion criteria

patients with coronary artery disease

  • Stable coronary artery disease regardless of intervention (PCI or CABG)
  • Speaking Dutch language

Exclusion criteria

patients with coronary artery disease

  • Left ventricular ejection fraction < 50%
  • Hemodynamically significant valvular disease
  • Atrial fibrillation
  • Peripheral vascular, neurological and orthopaedic conditions impairing exercise capacity
  • Severe psychological and cognitive impairments

Treatment and study plan

Fitbit Charge 2

Device

Energy expenditure (kcal) assessed by this activity tracker will be compared with indirect calorimetry (Oxycon Mobile) during a laboratory activity protocol. Two groups will be assessed: patients with stable coronary artery disease (CAD) and patients with heart failure with reduced ejection fraction (HFrEF).

Mio Slice

Device

Energy expenditure (kcal) assessed by this activity tracker will be compared with indirect calorimetry (Oxycon Mobile) during a laboratory activity protocol. Two groups will be assessed: patients with stable coronary artery disease (CAD) and patients with heart failure with reduced ejection fraction (HFrEF).

Oxycon Mobile

Device

The Oxycon Mobile will be used as the reference method/golden standard to calculate energy expenditure (kcal). This device (consisting of a face mask and gas analyzer unit) will be worn during the entire laboratory activity protocol.

Two groups will be assessed: patients with stable coronary artery disease (CAD) and patients with heart failure with reduced ejection fraction (HFrEF).

Primary outcomes

  1. Agreement

    Time frame: During a laboratory protocol consisting of 14 low-to-moderate intensity activities (39 minutes in total, resting time excluded)

    Energy expenditure (measured in kcal) will be extracted from both activity trackers for each separate activity of the protocol as well as for the total protocol.

    Breath-by-breath oxygen uptake (VO2) and carbon dioxide production (VCO2) will be measured during the entire length of the protocol using the Oxycon Mobile (reference method). By using the Weir equation, energy expenditure (kcal) will be calculated from VO2 and VCO2.

    Agreement of energy expenditure measurement is assessed by using mean differences in energy expenditure measured by the activity trackers versus the Oxycon Mobile and by calculating an intra-class correlation coefficient.

Secondary outcomes

  1. Responsiveness

    Time frame: Cycling at three different intensities (3 minutes at each intensity) and treadmill walking at three different intensities (3 minutes at each intensity))

    Responsiveness (i.e. ability to detect within-patients changes of energy expenditure measurement over time) of the activity trackers will be calculated by using a paired T-test during walking and cycling at different intensities.

Sponsors and collaborators

Lead sponsor

Maxima Medical Center

Other

Registry information

Official study title

Validation of Two Wrist-worn Devices for the Assessment of Energy Expenditure in Patients With Chronic Heart Failure and Coronary Artery Disease.

Important dates

Study start
2017
Primary completion
2018
Study completion
2018
First posted
May 15, 2019
Registry last updated
May 15, 2019

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.