CHU de Bordeaux
Pessac, 33604, France
NCT Number: NCT03031587
Radiofrequency ablation is the primary treatment for atrial and ventricular arrhythmias resistant to medication. However, the absence of assessment of injury creation during radiofrequency application is an important issue. One of the objectives of the Institut Hospitalo-Universitaire (IHU) Liryc (l'Institut de Rythmologie et Modélisation Cardiaque) is to improve ablation procedures by radiofrequency of cardiac arrhythmias. This is based on thermometric imaging by Magnetic Resonance Imaging (MRI) which allows a real time visualization of tissue temperature in all the myocardium with sufficient spatial and temporal resolution to characterize the induced thermal lesion. Today, investigators have developed and validated a new method for cardiac thermometry, associating rapid MRI acquisition technique (4 to 5 slices per heart beat) with online image reconstruction and correction algorithms against residual motion, magnetic susceptibility, drift of the magnetic field, etc... Recent preclinical studies showed a precision of 1°Celsius in the myocardium, largely sufficient to characterize a thermal treatment induced by radiofrequency where typical temperature rises of 40°C are observed during ablation. Temporal evolution of the temperature in each pixel provides access to calculation of the accumulated thermal dose that is a relevant indicator of the induced necrosis.
This imaging method must now be evaluated in humans in order to test its robustness under real conditions (presence of arrhythmias, corpulent patients, etc…) and to optimize acquisition parameters and image processing. The aim of this research is thus to obtain specific MRI sequence of images of patients, on which will be evaluated the different algorithms of reconstruction and processing for temperature imaging. This study is a mandatory step in the perspective of future clinical treatments of cardiac arrhythmia under MRI.
Looking for future studies?
Notify Me15 year and older
All sexes
Interventional
Not applicable
Pessac, 33604, France
Radiofrequency ablation is the primary treatment for atrial and ventricular arrhythmias resistant to medication. However, the absence of assessment of injury creation during radiofrequency application is an important issue in that it can result either in recurrences of arrhythmia requiring redo procedures when an inadequate lesion is created, or on the opposite in serious complications when the lesion created is too large and extents to extra-cardiac territory that should be preserved. The imaging team of the IHU-Liryc develops new methods in cardiac MRI in view of diagnostics (improve spatial and temporal resolution, dynamic 3D imaging or contrast improvement) and therapeutics. Hence, one of the objectives of the IHU-Liryc is to improve ablation procedures by radiofrequency of cardiac arrhythmias in order to make them more effective (Real-time visualization of the thermal lesion, allowing application of the sufficient energy needed for a transmural lesion), and safer avoiding excessive lesion responsible for perforation and extension to extra-cardiac structures. This is based on thermometric imaging by MRI which allows a real time visualization of tissue temperature in all the myocardium with sufficient spatial and temporal resolution to characterize the induced thermal lesion. MRI thermometry was developed during the last decade and successfully applied clinically over a wide range of organs (the uterus, the brain, the liver, the kidneys) for direct monitoring of thermal treatment of various pathologies (fibroids Uterus, bone metastasis, liver cancer). This innovative technic was not applicable to cardiac arrhythmias due to the respiratory and cardiac movements whose rhythms can be irregular, as well as thermal noise generated by blood flow on images. Today, our team has developed and preclinically validated a new rapid MRI method dedicated to cardiac thermometry. All patients who give their oral agreement to participate to the study will have added to their examination some acquisition sequences. The maximum additional time due to the specific acquisitions of the study will be 5 minutes, over an average clinical examination time of 45 minutes. No follow-up or visit of end of treatment will be performed, the end of patient participation in this research corresponding to the end of the MRI examination.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
It deals with specific sequences of rapid imaging acquisition in gradient echo (4 to 5 slices/cardiac cycle) with synchronization on the surface ECG systematically included in a cardiac MRI examination, together with update of the slice position depending on the respiratory state (established technique of navigator echo). The acquisition is repeated over 300 cardiac cycles to monitor myocardial temperature changes
cardiac MRI
Time frame: Day 0
1 measurement of temperature (°C) by cardiac beating
University Hospital, Bordeaux
Other
Acronym: VAIMTH-IRM
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05103852
Cardiac MRI, Right Cardiac Catheterization
Massy, France
View Trial DetailsNCT03661827
Arterial Occlusive Diseases, Arteriosclerosis
Leicester, United Kingdom
View Trial DetailsNCT02655770
Cardiac MRI, Diabetes Mellitus
Copenhagen Ø, Denmark
View Trial DetailsNCT07577466
Amyloid Neuropathies, Amyloid Neuropathies, Familial
Düsseldorf, North Rhine-Westphalia, Germany
View Trial Details