USC Clinical Exercise Research Center
Los Angeles, California, 90033, United States
NCT Number: NCT01209923
The purpose of this study was to validate the Stayhealthy BC1 bioelectrical impedance analyzer to assess percent body fat in children and adults. The BC1 was compared to dual-energy x-ray absorptiometry assessment of body fat for adults and to hydrostatic weighing assessment of body fat for children. We hypothesized that the BC1 would provide similar measures of body fat between devices with acceptable limits of agreement.
Looking for future studies?
Notify Me10 year–80 year
All sexes
Interventional
Not applicable
Los Angeles, California, 90033, United States
The BC1 body composition analyzer is manufactured by Stayhealthy. It is a handheld, noninvasive bioelectrical impedance device. When held, the BC1 sends an electrical impulse through the body to determine body fat, muscle mass, and body hydration. Bio-impedance devices measure the change in electrical resistance in body tissues by using a detectable electrical signal that passes through the body. The method is based on the principle that lean body mass contains virtually all the water and conducting electrolytes in the body and provides a good electrical pathway. In contrast, fat or fat-containing tissues produce a poor electrical pathway. By inducing a low-energy, high -frequency signal, a measurement of the baseline resistance to flow of electrical current can be assessed. The resistance measurement relates directly to the volume of the conductor. Through repeated measurements and identifying other parameters (i.e. gender, weight, age and height) proprietary equations were developed that determine total body water, fat free body mass, and total body fat.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Body composition measures taken twice at the same visit for BIA, DEXA, and hydrostatic weighing.
Other names: BIA, underwater weighing, DEXA scanning, BC1
Time frame: 2 measures were assessed during a single visit
Percent body was compared between devices
University of Southern California
Other
Validation of the BC1 Bioelectrical Impedance Body Comp Analyzer
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07731633
Body Composition, Cardiometabolic Health
Martin, Žilina Region, Slovakia
View Trial DetailsNCT07628790
Autonomic Function, Behavior
Seoul, South Korea
View Trial DetailsNCT07724119
Behavior, Behavior, Animal
Wroclaw, Lower Silesian Voivodeship, Poland
View Trial DetailsNCT07385534
Arterial Occlusive Diseases, Arterial Stiffness, Blood Pressure
Seoul, South Korea
View Trial Details