Skip to main content
OpenTrials
Recruiting

NCT Number: NCT05971719

Validation of a System Using Aerosol Glycerine to Detect and Localize Intraoperatively Pulmonary Air Leaks

Air leaks represent one of the most common complications and postoperative morbidity in thoracic surgery. Air leaks have been associated with the largest preventable morbidity associated with increased costs following lobectomy (typically related to increased length of stay). However, the standard used to detect and localize the air leaks, the submersion test, is not suitable for the standard surgical procedure, Video Assisted Thoracic Surgery. Considering the prevalence of this complication and the absence of a surgical standard of care for such complications, the aim of this study is to develop a system to create and send a glycerine aerosol smoke in the lungs of the patient. The smoke is visible with standard laparoscope and will flow though the pulmonary leak, thereby reducing postoperative surgical complications, morbidity, and length of stay for patients undergoing pulmonary resection.

Recruiting

Interested in participating?

Request Info

Key information

Conditions

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients undergoing lung transplant surgery
  • Organ donor ineligible to donate lungs

Exclusion criteria

  • Healthy individuals

Treatment and study plan

Air Leaks: Aerosol glycerine System

Diagnostic Test

A range of different leak will be done with different needle sizes on the lung. Perform localization on staple lines used surgically during pulmonary surgeries, as they are known to not consistently give an airtight closure. The lung will be put in the ex-vivo model and ask for a surgeon to localize the leaks with our system. The needle incisions will be repeat on another lung and ask the same surgeon to localize the leaks with the submersion test. To perform the submersion test the surgeon will have to submerge the lung in saline solution and to check the presence of air bubbles. The lung is inflated to pressures of 20 to 40 cm H209. The precision of both systems will be compared by the minimal incision the minimal incision the surgeon was able to localize.

Primary outcomes

  1. Localization efficacy

    Time frame: 48 months

    Puncture the lungs to achieve an average size air leak (1-2 cm) and ask the surgeon to identify the airleak with the localization system. Register a success if the surgeon has properly localized the air leak and a failure if the surgeon has failed to localize the air leak. Destinguish the failures in false positive (Air leak detected in a non leaking area of the lung) and false negative (Air leak not detected when present). Compare that efficacy rate to the efficacy of a similar experiement done with the submersion technique.

Secondary outcomes

  1. Duration of localization

    Time frame: 48 months

    Mesure the time required for the surgeon to localize the air leak area by the surgeon. Compare that time to the submertion test localization.

  2. Minimal leak localizable

    Time frame: 48 months

    Puncture the lungs with different needle sizes and ask a surgeon to localize the air leaks on the lung. Record the smallest hole the surgeon was able to localize with our system. Then, compare the minimal leak localizable with our system to the minimal leak localizable with the submersion test.

  3. Staple lines airtightness

    Time frame: 48 months

    Staple lines are known to not consistently give an airtight closure. But the manufacturers of those staple lines do not know why they are failing. Prove that the system can detect if the staple line is airtight or not, which could be useful for those manufacturers as well as for the clinicians. As leaks won't be created on every staple line, confirm that there is a leak by creating bubbles with saline at the staple line on the ex-vivo lung. Ask a surgeon to give the outcome of the airtightness of the staple line (success or failure) and then, compare the outcome to what we obtained with the localisation system.

Study contacts

Contact information is provided by the study sponsor or research team.

Adeline Jouquan, MSc

CONTACT

[email protected]

514-890-8000 ext. 26214

Moishe Liberman, MD

CONTACT

[email protected]

514-890-8000 ext. 26832

Sponsors and collaborators

Lead sponsor

Centre hospitalier de l'Université de Montréal (CHUM)

Other

Registry information

Acronym: CT0136

Important dates

Study start
2023
Primary completion
2027
Study completion
2027
First posted
Aug 2, 2023
Registry last updated
Mar 18, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.