Skip to main content
OpenTrials
Completed

NCT Number: NCT03750097

Validation of a Smartwatch in Persons With Multiple Sclerosis

The study is designed to validate the accuracy of steps detected by a commercially available smartwatch in persons with multiple sclerosis. Specifically, the investigators examine whether a smartwatch can detect steps accurately during slow, comfortable and fast overground walking. The total steps counted by the smartwatch will be compared to those counted by an accelerometer commonly used in clinical studies and the actually walked steps.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Department of Sport Science and Sport, Gebbertstr. 123b

Erlangen, 91058, Germany

About this study

Multiple sclerosis (MS) is a chronic inflammatory disease of the central nervous system. It is one of the most common neurological diseases in young adulthood. The main symptoms of MS are gait and mobility impairments, which also determine the severity of the disease. Currently, subjective clinical functional tests are commonly used to evaluate therapy outcomes. Due to advancing mechanization, body-worn accelerometers have been established as a potential instrument for the objective detection of mobility in clinical research. The accuracy of these devices for determining the mobility is therefore essential. However, current studies, especially in people with altered gait, show large deviations in step detection accuracy.

In the present study we want to investigate: i) whether a commercially available smartwatch (Polar M600) counts steps in persons with multiple sclerosis (pwMS) accurately and ii) whether it counts steps as accurately as an accelerometer commonly used in clinical research (ActiGraph wGT3X-BT). In addition, the accuracy of the step detection by the algorithms of the manufacturer of the two devices (Polar M600 and ActiGraph wGT3X-BT) will be compared with an own-developed algorithm.

For this purpose, 63 pwMS with low to severe functional restriction (EDSS: 0 - 6.5) will participate in this validation study. The validation protocol consists of three walking tests with different walking velocities. During these three conditions the participants will wear the Polar M600 on the wrist and the ActiGraph wGT3X-BT with a belt over the hip. In the first walking test, the subjects will complete 250 steps with comfortable walking velocity (CWV). After a sufficient break, the participants will be randomly assigned to either a fast walking velocity condition (FWV: CWV + 20%) followed by a sufficient period of rest and a slow walking velocity condition (SWV: CWV - 20%) or vice versa. Each of the walking tests with modified walking velocity also consists of 250 steps. To analyze the accuracy of step detection, the measured steps of the devices will be compared with the actually walked 250 steps.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Multiple Sclerosis with Expanded Disability Status Scale between 0 - 6.5
  • Ability to walk 250 steps with or without an assistive device

Exclusion criteria

  • Clinically relevant cardiovascular or orthopaedic disease
  • Severe polyneuropathy
  • Cognitive impairment

Treatment and study plan

Comfortable walking velocity (CWV)

Behavioral

Walking for 250 Steps with self-selected comfortable walking velocity while wearing the two accelerometers (Polar M600 and ActiGraph wGT3X-BT)

Slow walking velocity (SWV: CWV - 20%)

Behavioral

Walking for 250 Steps with slow walking velocity while wearing the two accelerometers (Polar M600 and ActiGraph wGT3X-BT). Slow walking consists of walking with 20% slower than the self-selected comfortable walking velocity by following a researcher who controls the walking velocity with a measuring wheel.

Fast walking velocity (FWV: CWV + 20%)

Behavioral

Walking for 250 Steps with fast walking velocity while wearing the two accelerometers (Polar M600 and ActiGraph wGT3X-BT). Fast walking consists of walking with 20% faster than the self-selected comfortable walking velocity by following a researcher who controls the walking velocity with a measuring wheel.

Primary outcomes

  1. Step detection during comfortable walking

    Time frame: Following the comfortable walking velocity protocol, an average of 2 minutes

    Step detection accuracy of the two devices (Polar M600 and ActiGraph wGT3X-BT) for both the standard algorithm and the self-developed algorithm during comfortable walking for 250 steps.

Secondary outcomes

  1. Step detection during slow walking

    Time frame: Following the slow walking velocity protocol, an average of 2 minutes

    Step detection accuracy of the two devices (Polar M600 and ActiGraph wGT3X-BT) for both the standard algorithm and the self-developed algorithm during slow walking for 250 steps.

  2. Step detection during fast walking

    Time frame: Following the fast walking velocity protocol, an average of 2 minutes

    Step detection accuracy of the two devices (Polar M600 and ActiGraph wGT3X-BT) for both the standard algorithm and the self-developed algorithm during fast walking for 250 steps.

Sponsors and collaborators

Lead sponsor

University of Erlangen-Nürnberg

Other

Collaborators

  • Neurological Rehabilitation Center Quellenhof
  • ZTM Bad Kissingen

Registry information

Official study title

Validation of a Commercially Available Smartwatch for Step Detection in Persons With Multiple Sclerosis

Important dates

Study start
2018
Primary completion
2018
Study completion
2019
First posted
Nov 21, 2018
Registry last updated
Apr 12, 2019

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.