Modified Bakay technique (MT)
ProcedureThe conventional standard technique for laparoscopic hysterectomy was followed until the colpotomy. The remaining steps were as follows: A 0-Monocryl™ violet (poliglecaprone-25) or a 0-PDS-II (polydioxanone) suture with a 36-mm needle (Ethicon Inc., NJ, USA) was placed first on the right USL, proximal to the ischial spine and 1-3 cm away from its uterine insertion, then helically proceeded by 1 to 3 bite(s) (depending on the length of the ligament) for suspension/plication. The suture continued circumferentially in counter clockwise direction on the line between the cervicovaginal junction and the bladder in a full-thickness purse string fashion, at least 1 cm away to the bladder. This suture symmetrically ended in the left USL, with forming nearly an Ohm sign (Ω). Colpotomy was performed circumferentially using laparoscopic cold scissors and/or knife, maintaining a safe distance from the suture line. Following removal of the uterus, both ends of the prior suture line were knotted.