Rabin Belinson, Medical Center - Israel
Petah Tikva, Israel
Location status: Recruiting
Location contact
Ran Kornowski, Prof.
CONTACT
NCT Number: NCT05448833
The objective of this study is to evaluate the safety and performance of the V-LAP System in subjects with New York Heart Association (NYHA) functional class II and III HF, irrespective of left ventricular ejection fraction.
Interested in participating?
Request Info22 year–88 year
All sexes
Interventional
Not applicable
Petah Tikva, Israel
Location status: Recruiting
Ran Kornowski, Prof.
CONTACT
The trial is designed to demonstrate that the V-LAP™ implant can be positioned in the interatrial septum.
The V- LAP™ System is intended for wirelessly measuring and monitoring LAP. The V-LAP™ System is indicated for subjects with chronic symptomatic ACC/AHA Stage C.
Pressure-guided medical management of study participants, with the goal of reducing hospitalizations and improving quality of life, will be implemented using a physician-directed patient self-management approach.
V-LAP-PSM (Patient Self-management), Patient Guidance Application is a smartphone application that guides the patient on how to self-adjust the treatment, according to physician prescription, and when to approach the study investigator.
Safety will be monitored by the occurrence of adverse events throughout the trial.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
*Thresholds for NT-proBNP will be corrected for body mass index (BMI) using a 4% reduction per BMI unit over 20 kg/m2. If subject is on ARNI, NT-proBNP should be used exclusively.
Exclusion criteria
Intra Procedural Exclusion Criteria:
(Intra Procedural Exclusion Criteria will be determined immediately after intracardiac echocardiography or transesophageal echocardiography determination of left atrial anatomy and just before transseptal puncture) 26. Anatomical anomaly on TEE or ICE that precludes implantation of the V-LAPIM across the interatrial septum (Fossa Ovalis) including: Septal thickness at fossa > 5 mm, FO Dimension <16mm, ASD or PFO with more than a trace amount of shunting, intra-cardiac thrombus felt to be acute and not present on prior exams and abnormal septum, e.g., a hypermobile septum or a septal aneurysm.
Delivery of the V-LAP™ implant by right heart catheterization. A catheter-based approach in a trans-septal puncture procedure, deploying it in the inter-atrial septum.
Time frame: Up to 12 months post-procedure
Freedom from failure of the V-LAP system to obtain LAP measurement from the sensor implant and transmit the LAP data to the V-LAPDD Data Display and the V-LAPPSM Patient Guidance Application.
Time frame: Up to three months post-procedure
Number of participants with study (Device and/ or system) related to Major Adverse Cardiac and Neurological Events (MACNE) - as defined in the protocol, as by the independent Clinical Events Committee
Time frame: At index (Implantation visit)
LAP accuracy validation, concordance of the V-LAP implant measurement with pulmonary capillary wedge pressure (PCWP) measurement
Contact information is provided by the study sponsor or research team.
Vectorious Medical Technologies Ltd.
Industry
V-Lap System For Wirelessly Measuring And Monitoring Left Atrial Pressure (Lap) In Patients With Advanced Chronic Heart Failure
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07081711
Aortic Diseases, Arrhythmias, Cardiac
Cleveland, Ohio, United States
View Trial DetailsNCT07592494
Cardiac Resynchronization Therapy Devices, Cardiovascular Diseases
Çorum, Turkey (Türkiye)
View Trial DetailsNCT07574593
Cardiovascular Diseases, Heart Diseases
Chula Vista, California, United States
View Trial DetailsNCT07278583
Cardiovascular Diseases, Heart Diseases
Clermont-Ferrand, France
View Trial Details