Kidney and Pancreas transplantation is considered the treatment of choice for many people with End Stage Renal Disease and Type 1 diabetes because quality of life and survival is often better after transplantation. However the quality of organs varies as does the quality of perfusion once they are transplanted. The immediate determinant of the survival of any transplanted allograft often depends on the overall quality of perfusion of the organ. The assessment of perfusion is currently visually and empirically done and reported by the surgical team, with low objectivity. The Laser Speckle Doppler technique will be used in both kidney and pancreas transplantation to objectively study the quality of blood flow to the kidney and pancreas after transplantation. This Doppler will provide continuous, non-invasive blood flow monitoring of the microvascular environment of the transplanted organ. The strength of the technique is in evaluating changes in flow over an area of interest or the whole transplanted organ and accurately numerically quantifying the flow. The laser speckle Doppler technique is now well established and has been used in various clinical and research setting as the most convenient means of assessing tissue blood flow. It has however not yet been used in kidney and pancreas transplantation.
Looking for future studies?
Notify Me18 year–75 year
All sexes
Observational
Manchester, Greater Manchester, M13 9WL, United Kingdom
BACKGROUND After reperfusion in solid organ transplantation, the quality of organ reperfusion is often assessed visually and reported as good, moderate, reasonable, patchy or poor. In our centre a Renogram is usually performed which uses radioactive tracer which most kidney transplant recipients would have within 24 hours after transplantation to assess the overall perfusion of the allograft. The Speckle Laser Doppler is a powerful clinical tool to obtain full field, high resolution images of microvascular perfusion of an organ It has been used in many medical fields such as dermatology vascular medicine and neurosciences both in a research and in clinical settings. This study seeks to utilise this technique to try to accurately quantify perfusion in the kidney and pancreas after transplantation and to develop a robust numerical quantification system of reporting on organ perfusion.
The Speckle Laser Doppler blood flow imager uses the laser speckle contrast technique to deliver real-time blood flow images with numerical physical data, providing outstanding performance in a wide range of pre-clinical and clinical research applications. This technique has not yet been applied for the assessment of kidney transplant perfusion reporting.
RESEARCH QUESTION/AIM(S)
.
Objectives
This study aims to utilise this technique to try to accurately quantify perfusion in the kidney and pancreas after transplantation and to develop a robust numerical quantification system of reporting on organ perfusion
Outcome Circulating markers of hypo perfusion and kidney injury will be measured to include: lactate, glutamate, pyruvate, Interleukin 6 as well as glutathione a marker of oxidative stress and assess their correlation with outputs from the two devices.
RATIONALE This study seeks to utilise this technique to try to accurately quantify perfusion in the kidney and pancreas after transplantation and to develop a robust numerical quantification system of reporting on organ perfusion.
The moorFLPI-2 blood flow imager uses the laser speckle contrast technique to deliver real-time blood flow images with numerical physical data, providing outstanding performance in a wide range of pre-clinical and clinical research applications. This technique has not yet been applied for the assessment of kidney transplant perfusion reporting.
STUDY DESIGN and METHODS of DATA COLLECTION AND DATA ANALYIS Speckle Doppler The Speckle Laser Doppler blood flow imager will be used to obtain real-time blood flow images at reperfusion and immediately thereafter this imaging will occur immediately after the surgery when the patient is still under anaesthetic it will take approximately 15 minutes. Initially these images with the flow parametric data will be stored on a laptop which comes with the rental equipment. However once the study is complete, all images and data will be stored on a desktop/drive in the department along with other departmental research data confidentially. The software integrated in the equipment incorporates multiple blood flow parameters and a statistical analytical package for an exhaustive analysis of various parameters. The Speckle Laser Doppler has two low power visible aiming lasers that indicate the approximate centre of the image. The aiming lasers will appear as a single point at a distance of 25 cm. As the distance is increased or decreased from 25 cm, the aiming lasers will appear as two separate points with the centre of the image being located at the midpoint between them. The aiming lasers can be turned on or off by pressing the button on the scan head or from the System Setup window in the PC software.
The moorFLPI-2 measurement software provides two measurement modes that can be used separately or in combination:
Blood samples Concurrently blood samples will be obtained on each patient on Day 0 (day of transplantation), after reperfusion to measure markers of hypo perfusion and kidney injury: lactate, glutamate, pyruvate, Interleukin 6 as well as glutathione a marker of oxidative stress
Clinical Follow up
Patients will be monitored for 3 years following their transplant to look for any transplant related problems which may relate to the quality of the organ as assessed by speckle Doppler.
Sample size and Statistical analysis This is an exploratory study to evaluate the use of Doppler in kidney transplants and as such sample size is mainly dictated by pragmatic considerations and what is available for the duration of hiring the device. Nevertheless sample of 68 is sufficient to provide reasonable precision for the agreement and correlation tests intended for this study in an exploratory level. The analyses will be mainly descriptive. Tests will be exploratory and in the view of generating information for future larger studies.
Research Q1 The software integrated in the equipment incorporates multiple blood flow parameters and a statistical analytical package for an exhaustive analysis of various parameters. The comparison between the 2 methods for measuring blood flow will be assessed for agreement using the appropriate statistical methodology.
The continuous variables for markers of inflammation, circulating markers of hypo perfusion and oxidative stress will also be assessed for any correlation with speckle Doppler perfusion measurements.
Events at the end of 3 years follow up will be compared with the blood flow measurements in categorical analysis.
STUDY SETTING Our unit performs the largest number of kidneys transplants in the UK so has access to a large number of samples for this project.
All members of the team have academic track records and participate in several on-going research projects. Current research projects are investigating cardiovascular disease, kidney perfusion, and MR imaging.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Inclusion criteria
Kidney Transplant Recipients
Pancreas Transplant Recipients
Exclusion criteria
Exclusion criteria
Speckle Doppler Laser imaging
Other names: Laser Imaging
Blood sampling
Other names: Venepuncture
Time frame: 3 months
Doppler imaging of kidneys and pancreas
Time frame: 6-12 months
Circulating biomarkers of inflammation and oxidative stress
Manchester University NHS Foundation Trust
Other Gov
Using the Speckle Doppler to Quantify Perfusion Quality in Kidney and Pancreas Grafts on Vascular Reperfusion
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03611621
Behavior, Kidney Transplant Failure and Rejection
Los Angeles, California, United States
View Trial DetailsNCT06016283
Behavior, Coitus
Rotterdam, South Holland, Netherlands
View Trial DetailsNCT04057742
Behavior, Kidney Transplant Failure and Rejection
Madison, Wisconsin, United States
View Trial DetailsNCT05816486
Behavior, Kidney Transplant Failure and Rejection
Brasil, Brazil
View Trial Details