Patients with a total hip replacement may require early revision surgery due to an adverse local tissue reaction or bone resorption that occurs due to wear debris released from the implant. MRI provides a non-invasive biomarker for clinicians and surgeons to detect early adverse synovial reactions which may exist in the absence of clinical symptoms, thus imparting essential information for clinical management. This study will address two of the most commons causes of hip implant failure, including adverse local tissue reaction in implants not traditionally associated with adverse tissue reactions, as well as the presence of aseptic loosening and loss of implant-bone integration.
Interested in participating?
Request Info21 year–95 year
All sexes
Observational
New York, 10021, United States
Location status: Recruiting
Hollis G Potter, MD
PRINCIPAL_INVESTIGATOR
Matthew F Koff, PhD
PRINCIPAL_INVESTIGATOR
Matthew Koff, PhD
CONTACT
Mauro Miranda, MFA
CONTACT
Total hip arthroplasty (THA) has been successful in achieving pain reduction, but recent concerns have been raised regarding the development of adverse local tissue reactions (ALTRs). Our group has previously found that: 1) Magnetic resonance imaging (MRI) can detect and distinguish wear debris from THA; 2) MRI is sensitive to ALTR damage from different articulating surfaces; and 3) variable host-mediated response to wear debris mounts distinct morphologic patterns on MRI. There is continued interest in the evaluation of soft tissues near THAs as traditional THA designs, including metal-on-polyethylene (MOP) and ceramic-on-polyethylene (COP) bearing surfaces, have recently been implicated in ALTRs. It is believed that fretting and corrosion at the head-neck junction is responsible for ALTRs, secondary to flexural rigidity and other implant mechanical features. If a greater prevalence of ALTR is found in components with more flexible connections, this could drive the practice of THA to stiffer connections.
In this study, we will evaluate two important causes of implant failure: (1) in designs not traditionally associated with ALTRs such as metal-on-polyethylene (MOP) and ceramic-on-polyethylene (COP) we will assess patients indicated for revision THA surgery with MRI and correlate the imaging metrics to targeted biopsy retrieval obtained at the time of revision (including the trunnion), the extent of tissue damage documented at surgery, and implant retrieval analysis of the neck trunnion, including flexural rigidity analysis; and (2) to longitudinally assess implant integration using qualitative MRI evaluation of the bone-implant interface as well as quantitative MRI techniques, T2 mapping and T2* mapping using MAVRIC-UTE, to evaluate relaxometry at the interface.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Cohort #1:
Cohort #2:
Exclusion criteria
Cohort #1:
Cohort #2:
Time frame: An expected average of 1 year post-operatively
All enrolled arthroplasty designs will be evaluated utilizing the input of:
Time frame: This outcome will be measured at 4 different time points: Initial office visit, 1 year follow-up, 2 year follow-up, 3 year follow-up.
All enrolled arthroplasty designs will be evaluated utilizing the input of:
Time frame: An expected average of 1 year post-operatively
Patients will be classified as symptomatic with mechanical symptoms and symptomatic with unexplained pain. These groups are based on the categories used by the National Joint Registry of England and Wales. Patients presenting with loosening, instability, or malalignment will be classified as "mechanical" failure. In cases of loosening, patients will be categorized as having acetabular or femoral loosening, only when documented intra-operatively by the surgeon. Patients presenting with pain not attributable to implant loosening, instability, or component malposition will be classified as "unexplained" failure. No specific unit of measure will be used for this outcome measure.
Time frame: Measurement at an expected average of 1 year post operatively for revision total hip arthroplasty patients, or at initial office visit, 1 year follow-up, 2 year follow-up, and 3 year follow-up for individuals being monitored longitudinally.
Blood samples will be drawn into lithium-heparin containing tubes with non-contamination precautions, and analyzed with high resolution inductively coupled mass spectrometry for the most accurate assessment of Cobalt and Chromium metal ion levels, to be measured in parts per million (ppm) or microgram per liter (ug/L)
Time frame: Measurement at an expected average of 1 year post operatively for revision total hip arthroplasty patients, or at initial office visit for individuals being monitored longitudinally.
The assessment of hip replacement acetabular component position will be performed using the Einzel-Bild-Roentgen-Analysis (EBRA) software. The femoral stem-shaft angle will be measured in the frontal plane. The acetabular inclination angle will be measured in the frontal plane. The acetabular anteversion angle will be measured in the lateral plane. All measurements will be expressed in units of degrees.
Time frame: Measurement at an expected average of 1 year post operatively for revision total hip arthroplasty patients, or at initial office visit, 1 year follow-up, 2 year follow-up, and 3 year follow-up for individuals being monitored longitudinally.
Evaluation of MR images: Presence, location, type and volume (measurement units of mm^3) of synovitis, Synovial thickness (measurement units of mm), Impression of synovium, Decompression of synovitis, Decompression into Trochanteric Bursa, Decompression into Iliopsoas, Presence and location of low signal intensity deposits, Presence of soft tissue edema, Presence and location of dehiscence, Presence, location and volume (measurement units of mm^3) of osteolysis, Assessment of implant loosening, Presence of and location of neurovascular compression, Disruption of abductors due to distended pseudocapsule, Presence of enlarged lymph nodes and presence and grading of adverse local tissue reaction. All quantitative values have the units of measurement indicated.
Time frame: Measurement during revision surgery for total hip arthroplasty patients
A subjective scoring system will be used for intraoperative damage assessment of the hip joint. The system is based on a 0 to 3 scale denoting the level of involvement of the soft tissues surrounding the joint (capsule, synovium, and muscle): 0 = Normal tissue; 1 = Fluid collection ± mild synovial reaction with or capsular dehiscence; 2 = the same findings as a score of 1, but with moderate synovial reaction; and 3 = the same findings as a score of 2, but with the addition of damage to the abductor muscle and/or osteolysis. No specific unit of measure will be used for this outcome measure.
Time frame: Measurement at an expected average of 1 year post operatively for revision total hip arthroplasty patients.
Histological evaluation will be using a 10 point aseptic lymphocytic vasculitis associated lesion (ALVAL) score to assess tissue reaction to a total hip replacement. The ALVAL score is a summation of individual grades assigned to the integrity of the synovial lining, presence and extent of inflammatory cell infiltrates, necrosis and tissue organization.
We will use a supplemental grading system intended for metal-on-poly and ceramic implants since ALVAL grading is used primarily for metal-on-metal (MOM) articulations and may not detect similar features of wear debris in non-MOM articulations, polyethylene, metal or corrosion products. The presence of ceramic and polyethylene particles and the relative number of macrophages, giant cells, histiocytes, acute or chronic inflammatory cells, and presence of necrotic tissue will be graded using the scale of: 1) absent (-), little (+), moderate (++), extensive (+++). No specific unit of measure will be used for this outcome measure.
Time frame: Measurement at an expected average of 1 year post operatively for revision total hip arthroplasty patients.
The bearing surfaces of the femoral heads and acetabular components, the neck trunnion of the total hip replacement femoral stems, and the matching female tapers of the total hip replacement heads retrieved at surgery will be scanned with a technique that utilizes a non-contact measurement method to calculate volumetric wear (measurement units of mm^3) and linear wear (measurement units of mm).
Time frame: Measurement at an expected average of 1 year post operatively for revision total hip arthroplasty patients.
Quantitative imaging, specifically T2 mapping of soft tissues near the implant, specifically, the synovium and synovial volume.
Contact information is provided by the study sponsor or research team.
Matthew F Koff, PhD
CONTACT
Mauro Miranda, MFA
CONTACT
Hospital for Special Surgery, New York
Other
The Ability Of MRI To Detect Adverse Local Tissue Reaction And Implant Integration As A Function Of Hip Implant Modularity
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT01542580
Arthritis, Arthritis, Rheumatoid
Morton Grove, Illinois, United States
View Trial DetailsNCT01820611
Arthritis, Arthritis, Rheumatoid
Turku, Finland
View Trial DetailsNCT01882751
Complications; Arthroplasty
Knoxville, Tennessee, United States
View Trial DetailsNCT01373099
Arthritis, Complications; Arthroplasty
Chicago, Illinois, United States
View Trial Details