Intensive care unit, Beijing Tiantan Hospital, Capital Medical University
Beijing, Beijing Municipality, 100050, China
NCT Number: NCT03368326
Brain injured patients are at high risk of pain due to the illness itself and a variety of nociceptive procedures in intensive care unit. Since the disorder of consciousness, speech, and movement, it is usually difficult for them to self-report the presence of pain reliably. The Critical-Care Pain observation Tool (CPOT) has been recommended for clinical use in the critically ill patients when self-report pain is unavailable. Besides, it seems that the bispectral index (BIS), a quantified electroencephalogram instrument, can be used for pain assessment along with the CPOT tool in some nonverbal critical ill patients (e.g., intubated and deep sedation). However, the validity and reliability of CPOT and BIS for pain assessment in brain injured patients are still uncertain so far. So the aim of this research is to investigate the value of CPOT and BIS for pain evaluation in this specific patient group.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Observational
Beijing, Beijing Municipality, 100050, China
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The CPOT includes 4 behaviors: (1) facial expression, (2) body movements, (3) compliance with the ventilator, and (4) muscle tension. Each behavior is rated from 0 to 2 for a possible total score ranging from 0 to 8.
Other names: Bispectral Index (BIS)
Time frame: 1.Before nociceptive/non-nociceptive procedure; 2.Within the first 5 minutes after nociceptive/non-nociceptive procedure.
The CPOT includes 4 behaviors: (1) facial expression, (2) body movements, (3) compliance with the ventilator, and (4) muscle tension. Each behavior is rated from 0 to 2 for a possible total score ranging from 0 to 8.
Time frame: 1.Before nociceptive/non-nociceptive procedure; 2.Within the first 5 minutes after nociceptive/non-nociceptive procedure.
The BIS monitor is a noninvasive technology, which measures different electrocortical indices through electrodes placed on the patient's forehead. Its main variable, the BIS index, consists of a single number computed from a complex algorithmic equation based on the EEG data. Its value can range from 0 (complete EEG suppression) to 100 (fully awake).
Capital Medical University
Other
Use of Critical-Care Pain Observation Tool and Bispectral Index for Detection of Pain in Brain Injured Patients:A Prospective Observational Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02924844
Intensive Care
Nîmes, Gard, France
View Trial DetailsNCT05917574
Critical Illness, Disease Attributes
Stevenage, United Kingdom
View Trial DetailsNCT07387731
Critical Illness, Disease Attributes
Porto Alegre, Rio Grande do Sul, Brazil
View Trial DetailsNCT04245878
Extubation, Intensive Care
Dijon, France
View Trial Details