t:slim X2 insulin pump with Control-IQ technology 2.0
Devicet:slim X2 insulin pump with Control-IQ technology 2.0, and wearing the Dexcom G6 sensor.
NCT Number: NCT05683392
The goal of this clinical trial is to assess safety of and explore glycemic outcomes with Control-IQ technology 2.0 in adults, children and preschoolers with type 1 diabetes.
Looking for future studies?
Notify Me2 year–80 year
All sexes
Interventional
Not applicable
Barbara Davis Center, Aurora, Colorado, United States
This feasibility study is a prospective, randomized, two-period crossover multi-center study of Control-IQ technology 2.0. After a two week run-in period, the automated insulin dosing (AID) system will be evaluated in multiple age groups over 4 weeks of use.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
t:slim X2 insulin pump with Control-IQ technology 2.0, and wearing the Dexcom G6 sensor.
Time frame: 2 weeks
Number of severe hypoglycemic events (with cognitive impairment such that assistance of another individual is needed for treatment) during study compared with data on severe hypoglycemic events reported by T1D Exchange clinic registry over a 3-month time period
Time frame: 2 weeks
Number of diabetic ketoacidosis during study compared with data on DKA events, compared with data on DKA events reported by T1D Exchange clinic registry over a 3-month time period
Time frame: 2 weeks
CGM percent time <54 mg/dL during each study period.
Time frame: 2 weeks
CGM percent time <70 mg/dL during each study period.
Time frame: 2 weeks
CGM percent time 70-140 mg/dL during each study period.
Time frame: 2 weeks
CGM percent time 70-180 mg/dL during each study period.
Time frame: 2 weeks
CGM percent time >180 mg/dL during each study period.
Time frame: 2 weeks
CGM percent time >250 mg/dL during each study period.
Time frame: 2 weeks
Mean CGM glucose mg/dL during each study period.
Time frame: 2 weeks
Glucose SD mg/dL during each study period.
Time frame: 2 weeks
Glucose Coefficient of Variation (%) during each study period.
Tandem Diabetes Care, Inc.
Industry
Control-IQ 2.0 Feasibility Study #2: Use of Control-IQ Technology 2.0 in Adults, Children, and Preschoolers With Type 1 Diabetes
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05488119
Autoimmune Diseases, Diabetes Mellitus
Stanford, California, United States
View Trial DetailsNCT07696780
Autoimmune Diseases, Diabetes Mellitus
Bern, Canton of Bern, Switzerland
View Trial DetailsNCT05610111
Autoimmune Diseases, Diabetes Mellitus
Charlottesville, Virginia, United States
View Trial DetailsNCT06308549
Autoimmune Diseases, Diabetes Distress
Bad Mergentheim, Baden-Wurttemberg, Germany
View Trial Details