Skip to main content
OpenTrials
Completed

NCT Number: NCT04651426

Use of a Non-medicated Plaster in Chronic Lumbar Back Pain.

The investigator assessed 54 patients with chronic lumbar back pain treated with FIT Therapy (far infrared technology) patch. The criteria for inclusion were chronic lumbar back pain due to overstress or to contracture and patients over 30 years old. Patients with tumors, infections, neurological and metabolic diseases were excluded. Three different types of FIT Therapy patches (F4, F3 and the placebo) were used according to the different power of action. The patches were self-removed after 5 days. At day 8 new ones were applied for other five days and at day 14 patients were dismissed. Every single patient was assessed during the study using the VAS pain scale, the Roland Morris questionnaire for quality of life and the range of motion (ROM).

Completed

Looking for future studies?

Notify Me

Key information

Age range

30 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Azienda Ospedaliera Universitaria Integrata

Verona, 37126, Italy

About this study

First and foremost, the investigators obtained the ethical committee approval, then 54 patients were enrolled since May 2019 to November 2019, at the AOUI (Azienda Ospedaliera Universitaria Integrata) Verona. Prospective analysis in a 3-arm, randomized double-blind and placebo-controlled study was performed to assess the effect of FIT Therapy patches on the chronic lumbar spine pain and on the ROM.

The FIT Therapy patch (D. FENSTEC s.r.l. Altavilla Vicentina, Italy) is a medical device class 1 which mechanism of action is through the ability of biominerals to reflect the far infrared radiation (FIR).

Normally the human body temperature would dissipate regular far infrared radiations but, thanks to the FIT Therapy (Far Infrared Technology), these waves are reflected and allowed to reach deeper areas in the human body (wavelength spectrum is 4-21 µm with a denser concentration around 11 µm).

Every FIT device act as a mirror and they are able to induce an antalgic effect simply thanks to this biophysical process, therefore without releasing any active ingredient or creating a thermic shock.

The plasters are made of 100% polypropylene non-woven fabric, an acrylic adhesive mass and a mix of titanium dioxide printed on. This particular mix in powder form is characterized by particles sizes above 100 nm. The intrinsic properties of the FIT technology are due to the mix of titanium dioxides that reflect the FIR emitted by the human body.

Three different plasters were used: a placebo (without any biomineral, therefore with no reflectance ability); an "F3" patch and an "F4" one, characterized by different power of action (F4 has a broader spectrum of refrigency than F3). The 3 plasters presented no difference in size, color and shape.

Patients were subdivided in 3 randomized groups.The Visual Analogic Scale (VAS) and the Roland Morris Disability Questionnaire (RMDQ) were used. The Range of Motion (ROM) evaluation consisted of flexion and extension, lateral bending and rotation of the lumbar spine.

The trial consisted of a total of 14 days for each patient. At day 0, during the first clinical encounter, patients were enrolled by signing an informed consent. Still during the encounter, the lumbar spine ROM was measured, the VAS and the RMDQ administered. Only after all these necessary steps the first patch was applied. Every patient was given a RMDQ and a journal, which had to be updated daily, and at the same time every day, with the pain level experienced and any adverse effect to the FIT Therapy patch. At day 5 the patch was self-removed and the RMDQ given during the first encounter filled. The second clinical encounter was at day 8. The patients' ROM and VAS were tested for the second time and a new FIT Therapy patch was applied. At day 13 the FIT Therapy patch was dismissed and a second RMDQ filled at home. The last clinical encounter was held at day 14 and once again all 54 patients' ROM and VAS were assessed. Finally, the daily journal was collected, and patients were asked if any other pain medication was self-administered during the entirety of the tests.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

:

  • chronic lumbar spine pain due to muscle contractures or over-use
  • a signed informed consent
  • patients 30 years of age or older.

Exclusion criteria

  • infections
  • neoplastic masses
  • neuropathies
  • metabolic disorders triggering the lumbar pain

Treatment and study plan

The FIT Therapy patch (D. FENSTEC s.r.l. Altavilla Vicentina, Italy) is a medical device class 1

Device

The FIT Therapy patch (D. FENSTEC s.r.l. Altavilla Vicentina, Italy) is a medical device class 1 which mechanism of action is through the ability of biominerals to reflect the far infrared radiation (FIR). Normally the human body temperature would dissipate regular far infrared radiations but, thanks to the FIT Therapy (Far Infrared Technology), these waves are reflected and allowed to reach deeper areas in the human body (wavelength spectrum is 4-21 µm with a denser concentration around 11 µm).

Every FIT device act as a mirror and they are able to induce an antalgic effect simply thanks to this biophysical process, therefore without releasing any active ingredient or creating a thermic shock.

The plasters are made of 100% polypropylene non-woven fabric, an acrylic adhesive mass and a mix of titanium dioxide printed on. This particular mix in powder form is characterized by particles sizes above 100 nm.

Primary outcomes

  1. The changes induced by the different types of FIT Therapy patches (placebo, "F3" and "F4"), in the pain level due to lower back pain, measured on the VAS scale.

    Time frame: The VAS scale results were compared, between the different patches, at day 0, 5, 8 and 14.

    VAS scale (Visual Analogic Scale)

Secondary outcomes

  1. Changes in the Range Of Motion (ROM)

    Time frame: The degrees of motion were absessed at day 0, day 8 and day 14

    Degrees of flexion-extension and lateral bending of the patient.

Other outcomes

  1. Changes in lifestyle.

    Time frame: The results of the RMDQ were absessed at day 0, day 8 and day 14

    Evaluated on the median values of the RMDQ (Roland Morris Disability Questionnaire)

Sponsors and collaborators

Lead sponsor

Azienda Ospedaliera Universitaria Integrata Verona

Other

Registry information

Acronym: CERFIT

Important dates

Study start
2019
Primary completion
2019
Study completion
2019
First posted
Dec 3, 2020
Registry last updated
Dec 3, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.