Completed

NCT Number: NCT02159560

Uniport and Multiport Epidural Catheters in Post-surgical Patients

The investigators hypothesize that multi-port thoracic epidural catheters will provide superior pain relief when compared to uniport catheters for post-surgical patients.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–75 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Beth Israel Deaconess Medical Center

Boston, Massachusetts, 02215, United States

About this study

Epidural analgesia (pain relief) is an effective treatment for post-surgical acute pain. The factors that determine the effectiveness of pain relief with epidural analgesia have been studied almost exclusively in the lumbar (low back) spaces for obstetrics (childbirth). These factors include the design of the epidural catheter, the type and dose of medications, and the volume of solution used. One of the important issues specific to the catheter design is whether the tip has a one end-hole, or multiple side holes. The number of holes has been suggested to affect the spread of epidural anesthetic over time, especially with low volume solutions. This has been demonstrated in older, stiffer epidural catheter designs, but has not been shown to be true with the newer, flexible epidural catheters.

The thoracic (upper back) epidural analgesia is widely employed for a many types of surgical pain. While the mechanism of pain relief is similar to that in the lumbar space, there may be differences between the two sites. Firstly, thoracic catheters tend to use low volume, high concentration medication solutions, which likely do not spread as effectively. Secondly, the thoracic catheters often need to be used for prolonged periods of time. Whereas the typical obstetric epidural is used for less than 12 hours, the post-surgical catheter is typically required for one to three days (or more). Finally, the thoracic space is narrow, with a thinner thecal sac, which might promote a difference in the spread of epidural solution.

Thoracic epidural analgesia is routinely used to control post-operative pain for a wide variety of surgical procedures. Based on the improved effectiveness of the one end-hole flexible epidural catheter in obstetrics, this design is commonly used in thoracic epidural analgesia. It has been observed that thoracic epidurals are somewhat less effective after a period of time when compared to the effectiveness of labor epidurals. This may be in part due to the inappropriate assumption that the thoracic epidural space of a post-surgical patient is the same as the lumbar space of a parturient.

The investigators seek to determine whether there is a difference in the analgesia provided by a thoracic multi-port epidural catheter when compared to a thoracic uniport epidural catheter as measured by pain scores, medication given for breakthrough pain, and need to add intravenous opioids. As mentioned previously, these catheters have been studied extensively in laboring patients but there is a striking paucity of literature regarding how anesthetic solutions spread in the thoracic epidural spaces of non-pregnant post-surgical patients and how this may be affected by catheter type. If the hypothesis is supported by results, it may change the practice within the study institution, and possibly, on a much larger scale. This study may also provide a foundation for further research into the physiology of the thoracic epidural space, how it differs from the lumbar epidural space, and how a medication solution spreads within this unique space.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • English speaking
  • Surgery in the thorax or upper abdomen
  • Age between 18 and 75
  • Expected use of epidural analgesia for >24 hours

Exclusion criteria

  • Contraindication to epidural catheterization
  • Chronic use of opioids
  • Chronic pain
  • Allergy to the standard medications used
  • Body Mass Index >40
  • Delirium
  • Dementia

Treatment and study plan

Epidural catheter

Device

The intervention is the use of an end-holed epidural catheter or three-holed side port epidural catheter

Primary outcomes

  1. Epidural Catheter Failure

    Time frame: 72 hours

    The primary outcome of the study will be the incidence of failed epidural analgesia, defined as the need to add intravenous opioids or halting or replacing the epidural catheter because of lack of pain control.

Secondary outcomes

  1. Number of Subjects Receiving Supplemental Treatments

    Time frame: 72 hours

    number of subjects receiving supplemental treatments required to maintain continual comfort

Other outcomes

  1. Median Dose of Medication

    Time frame: 72 hours

    Median dose (per hour) of medication required to maintain comfort

Sponsors and collaborators

Lead sponsor

Beth Israel Deaconess Medical Center

Other

Registry information

Important dates

Study start
2014
Primary completion
2021
Study completion
2021
First posted
Jun 10, 2014
Registry last updated