NCT Number: NCT04601623

Ultrasound to Predict the Prognosis of Rotator Cuff Tears

To predict the prognosis of large-to-massive RCTs and risk of re-tear by ultrasound elastography.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–80 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Kaohsiung Chang Gung Memorial Hospital

Kaohsiung City, 833, Taiwan

About this study

Most symptomatic large-to-massiverotator cuff tears (RCTs) should be operated, but the prognosis and postoperative risk of re-tear depended on the quality of rotator cuff muscles. Preoperative evaluations were usually done by magnetic resonance imaging (MRI). MRI was used in recent studies to predict the surgical outcome of large-to-massive RCTs and postoperative re-tear, but the clinical availability was not as good as ultrasound. The investigators hypothesize that ultrasound elastography can predict the prognosis of large-to-massive RCTs and risk of re-tear.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients who are diagnosed with rotator cuff tear by an orthopedist.
  • The large-to-massive rotator cuff tears need to be confirmed by magnetic resonance imaging or ultrasound. The definitions of this diagnosis include a tear over 3 cm or any full-thickness of tears in more than two rotator cuff muscles.
  • Being willing to cooperated with the arranged examinations before the operation.

Exclusion criteria

  • Patients who are only diagnosed with partial-thickness rotator cuff muscle tears or small- to large- sized full-thickness tears.
  • Patients who have acromioclavicular arthritis that needs distal clavicle resection.
  • Patients who had serious glenohumeral arthritis, pseudoparalysis, or any other shoulder trauma history.

Treatment and study plan

Sonoelastography

Other

This diagnostic test would be executed by a physician who has experiences of using Siemens Acuson S2000 ultrasound system for more than three year. The examination includes two of four rotator cuff muscles, listed as follows, supraspinatus muscle and infraspinatus muscle. Linear transducer (4-9 MHz) would be used for the whole test. The probe would be positioned along the longitudinal axis of the muscle belly. Compressive sonoelastography technique is used for semiquantitative analysis. In order to maintain the quality of images, quality factor needs to be over or equal to 60. The quantitative analysis was performed by shear wave sonoelastography and the region of interest (ROI) would be divided into four quadrants. The physicians will measure the shear wave velocity at the center point of each quadrant.

Primary outcomes

  1. Change from baseline finding of sonoelastography

    Time frame: Baseline, 3 months, 6 months, 12 months

    This diagnostic test would be executed by a physician who has experiences of using Siemens Acuson S2000 ultrasound system for more than three year. The examination includes two of four rotator cuff muscles, listed as follows, supraspinatus muscle and infraspinatus muscle. Linear transducer (4-9 MHz) would be used for the whole test. The probe would be positioned along the longitudinal axis of the muscle belly. Compressive sonoelastography technique is used for semiquantitative analysis. In order to maintain the quality of images, quality factor needs to be over or equal to 60. The quantitative analysis was performed by shear wave sonoelastography and the region of interest (ROI) would be divided into four quadrants. The physicians will measure the shear wave velocity at the center point of each quadrant.

Secondary outcomes

  1. Passive range of motions

    Time frame: Baseline, 3 months, 6 months, 12 months

    Passive range of motions of internal and external rotation, abduction, extension, and flexion, which are assessed by a goniometer.

  2. Muscle strength

    Time frame: Baseline, 3 months, 6 months, 12 months

    Muscle strength assessment include the following motions, which are internal and external rotation, abduction, extension, and flexion. They are measured by a manual dynamometer

  3. American Shoulder and Elbow Surgeons score (ASES score)

    Time frame: Baseline, 3 months, 6 months, 12 months

    Shoulder function is evaluated using American Shoulder and Elbow Surgeons score, which includes one item for pain (VAS) and 10 items for shoulder function. The ASES score ranges from 0 to 100, and the outcome is better when ASES score is higher.

  4. Western Ontario Rotator Cuff Index (WORC index)

    Time frame: Baseline, 3 months, 6 months, 12 months

    Shoulder function is evaluated using Western Ontario Rotator Cuff Index, which includes physical symptoms (10 items), sport/recreation/work function (4 items), lifestyle function (4 items), and emotional function (3 items). The WORC index ranges from 0 to 2100 or can be converted to 0 to 100 scale, and the outcome is better when WORC index is lower.

  5. WHOQOL-BREF (Taiwan version)

    Time frame: Baseline, 3 months, 6 months, 12 months

    The WHOQOL-BREF (Taiwan version) instrument comprises 28 items, which measure the following broad domains: physical health, psychological health, social relationships, and environment. The WHOQOL-BREF (Taiwan version) is a shorter version of the original instrument that may be more convenient for use in large research studies or clinical trials. The total score WHOQOL-BREF (Taiwan version) can be transformed to a 0-100 scale, and the quality of life is better when the score is higher.

  6. EQ-5D-3L

    Time frame: Baseline, 3 months, 6 months, 12 months

    The EQ-5D-3L descriptive system comprises the following five dimensions: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension has 3 levels: no problems, some problems, and extreme problems. The patient is asked to indicate his/her health state by ticking the box next to the most appropriate statement in each of the five dimensions. This decision results into a 1-digit number that expresses the level selected for that dimension. The digits for the five dimensions can be combined into a 5-digit number that describes the patient's health state.

  7. MRI

    Time frame: Baseline, 6 months

    MRI was performed on a 1.5T system (Signa Horizon LX, GE Healthcare) equipped with a standard shoulder surface coil. The shoulder MRI protocol was identical for all patients and consisted of axial proton-density-weighted fast spinecho with fat suppression sequence, the sequences was performed above the level o f the acromioclavicular joint down to below the axillary pouch with the following parameters: Coronal oblique proton-density-weighted with and without fat suppression, with axis parallel to the supraspinatus tendon, and sagittal oblique proton-density--weighted with and without fat suppression, with axis perpendicular to the coronal oblique axis, the ast spin-echo sequences were performed with the following parameters: TR msec/TE msec, 2700-4800 /25-40, echo-train length, 6; matrix, 256 × 256; field of view, 180 mm; section thickness, 2.5 mm with 2-mm gap. No IV or intraarticular gadolinium was administered.

Sponsors and collaborators

Lead sponsor

Chang Gung Memorial Hospital

Other

Collaborators

  • Ministry of Science and Technology, Taiwan

Registry information

Official study title

Ultrasound Shear Wave Elastography to Predict the Treatment Effect and Risk of Re-tear in Patients With Large-to-massive Rotator Cuff Tears

Important dates

Study start
2020
Primary completion
2021
Study completion
2021
First posted
Oct 26, 2020
Registry last updated
Mar 14, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.