Merve Karapinar
Isparta, Turkey (Türkiye)
NCT Number: NCT04660071
Echo intensity (EI) assessment using ultrasonography helps monitoring disease-induced muscle quality changes. However, there are no study investigating the reliability of EI in patients with knee osteoarthritis (OA). The primary aim of the present study was to investigate the inter and intra-rater reliability of EI evaluation by grayscale histogram analysis of quadriceps femoris muscle in patients with knee OA. The second aim was to compare the mean grayscale values obtained using both the Free Hand Tool (FHT) and Rectangular Marquee Tool (RMT) methods in ImageJ. Thirty patients with knee OA were included in this cross-sectional study. The echogenicity measurements of the Rectus Femoris, Vastus Inter-medius, Vastus Lateralis and Vastus Medialis were performed by two different researchers. Reliability analysis of EI measurements were calculated with using intraclass correlation coefficient (ICC), standard error of measurement (SEM) and coefficient of variation (CV) and Bland and Altman plot analysis.
Looking for future studies?
Notify Me40 year–65 year
All sexes
Observational
Isparta, Turkey (Türkiye)
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Ultrasound assessment was performed on rectus femoris (RF), vastus intermedius (VI), vastus medialis (VM) and vastus lateralis (VL) muscles using with an ultrasound-imaging device (Philips Medical Systems EPIQ 5 Release 5.0.2, Amsterdam).
All images were analysed using the Image J software (Version 1.48v, National Institutes of Health, Bethesda, MD, USA) by two different analysers (five years and one-year of experience in US image analysis).
Time frame: Thirty minute
Muscle echogenicity assessed by using ultrasound. Ultrasound assessment was performed on rectus femoris (RF), vastus intermedius (VI), vastus medialis (VM) and vastus lateralis (VL) muscles using with an ultrasound-imaging device (Philips Medical Systems EPIQ 5 Release 5.0.2, Amsterdam). Ultrasound Brightness mode (B-mode) with musculoskeletal scanning and a multi-frequency linear transducer (8-12 MHz, code: eL18-4) were used. For calculating echogenicity of muscles; all images obtained ultrasonography were analysed using the Image J software (Version 1.48v, National Institutes of Health, Bethesda, MD, USA) by two different analysers (five years and one-year of experience in US image analysis). The echogenicity results of the muscles performed by the two researchers recorded.
Hacettepe University
Other
Ultrasound Imaging of Quadriceps Muscle in Patients With Knee Osteoarthritis: Reliability of Echo Intensity Measurement
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07364578
Arthritis, Joint Diseases
Banī Suwayf, Egypt
View Trial DetailsNCT03895489
Arthritis, Joint Diseases
Edmonton, Alberta, Canada
View Trial DetailsNCT06693648
Arthritis, Joint Diseases
Thousand Oaks, California, United States
View Trial DetailsNCT06522906
Arthritis, Behavior
Tucson, Arizona, United States
View Trial Details