HT Centrum Medyczne
Tychy, Silesian Voivodeship, 43-100, Poland
Location contact
Marcin Romanczyk
SUB_INVESTIGATOR
NCT Number: NCT07606963
This study is a prospective, single-arm, non-randomized, single-site study, focused on evaluating the safety and efficacy of the Triton 1.5 System in diagnostic and basic therapeutic colonoscopy.
Trial opening soon.
Get Notified22 year and older
All sexes
Interventional
Not applicable
Tychy, Silesian Voivodeship, 43-100, Poland
Marcin Romanczyk
SUB_INVESTIGATOR
This study is a prospective clinical investigation designed to evaluate the safety, and efficacy of the Triton 1.5 System in performing diagnostic, screening, surveillance, and basic therapeutic tasks (e.g., polypectomy for lesions ≤ 2cm). Up to 40 subjects will undergo robotic colonoscopy using the Triton 1.5 System with three operating physicians.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Intra-Operative Criteria:
This study will serve to evaluate the safety and efficacy of the Triton 1.5 System for performing diagnostic, screening, surveillance, and basic therapeutic tasks (e.g., polypectomy for lesions ≤2cm).
Time frame: 48 Hours
Absence of Major Adverse Events (MAEs) within 48 hours of the procedure. MAEs are defined as the following: (a) Device-related death within 48 hours, (b) Perforation within 48 hours, (c) Intraprocedural bleeding preventing completion of the procedure, (d) Delayed bleeding within 48 hours accompanied by predefined symptoms and confirmed by a hemoglobin drop of >2 g, as applicable, leading to admission to hospital, prolongation of existing hospital stay, another procedure (requiring sedation/anesthesia).
Unit of Measure: Number of participants with at least one Major Adverse Event
Time frame: During Procedure
Completion of colonoscopy defined by both: (a) Successful cecal intubation with visualization of the appendiceal orifice, (b) Successful withdrawal with clinically acceptable diagnostic inspection and therapeutic access.
Time frame: During Procedure
Mucosal Injury graded using a visual assessment of the colonic wall during withdrawal of the procedure using the following scale: (1) Erythema / Bruising, (2) Mucosal break < 5 mm, (3) Mucosal break > 5 mm, (4) Muscle injury (non-full thickness), (5) Full-thickness injury.
Unit of Measure: Score (1-5), higher scores indicate more severe injury
Time frame: 14 days post-procedure
Delayed bleeding within 14 days, defined as: bleeding within 48 hours accompanied by pre-defined symptoms and confirmed by a hemoglobin drop > 2 g, leading to admission to hospital, prolongation of existing hospital stay, another procedure (requiring sedation/anesthesia).
Time frame: 14 days post-procedure
Delayed perforations within 14 days, defined as: perforations occurring within 14 days post-procedure.
Time frame: During Procedure
Interval from nested-system insertion at the anal verge to first visualization of the appendiceal orifice. Pauses for ancillary or therapeutic tasks (e.g., biopsy, polypectomy ≤ 2 cm, repositioning, prolonged washing) are recorded and subtracted to isolate insertion performance. For polypectomy pauses, time is measured from first polyp visualization to confirmation of retrieval in the specimen trap.
Unit of Measure: Minutes or seconds
Time frame: During Procedure
Number of times a participant was repositioned during the procedure. Unit of Measure: Number of repositioning events
Time frame: During Procedure
Clinically acceptable polypectomy performed with cold forceps, cold snare, or hot snare leaving no visible residual polyp. Polyps > 2 cm or lesions too complex for diagnostic colonoscopy are excluded and deferred for later advanced therapy.
Time frame: Immediately after Procedure
Physician's subjective workload assessment using the NASA Task Load Index (NASA-TLX), a validated tool consisting of six subscales: Mental Demand, Physical Demand, Temporal Demand, Performance, Effort, and Frustration. Each subscale is scored from 0 to 100 in increments of 5. Higher scores indicate greater perceived workload. Unit of Measure: Composite score (0-600)
Time frame: During Procedure
Percentage of subjects with ≥ 1 histologically confirmed adenoma or carcinoma Unit of Measure: Percentage of participants
Contact information is provided by the study sponsor or research team.
Hayley Holm
CONTACT
Min-Sun Son
CONTACT
Neptune Medical
Industry
Initial Clinical Experience With the Triton 1.5 Robotic System for Diagnostic Colonoscopy
Acronym: CARE II
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06935734
Colonic Diseases, Colonoscopy
View Trial DetailsNCT07612436
Colonic Diseases, Colonoscopy
View Trial DetailsNCT07261059
Colonic Diseases, Colonoscopy
View Trial DetailsNCT04921488
Colonic Diseases, Colonoscopy
Angers, France