Skip to main content
OpenTrials
Completed

NCT Number: NCT01328197

Treovance Stent-Graft With Navitel Delivery System for Patients With Infrarenal Abdominal Aortic Aneurysms

The primary goal of the study is to assess the safety and performance of the Treovance device in subjects with infrarenal aortic aneurysms, specifically to evaluate if the diseased pathology can be treated with an acceptable adverse event rate and that the device performs as expected. The results of this study will permit the establishment of endpoints and clinical design for a subsequent U.S. trial.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–85 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 1

Primary location

University of Massachusetts, Worcester, Massachusetts, United States

Loading trial locations.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Subjects with diagnosed with an infrarenal abdominal aortic aneurysm (AAA), with or without iliac artery involvement
  • Subjects with an infrarenal AAA that is >/= 4.5 cm in diameter for males, or >/= 4.0 cm in diameter for females, or has increased in diameter by 0.5 cm in the last 6 months
  • Subjects who consent to participate
  • Subjects who agree to comply with the follow-up schedule

Exclusion criteria

  • Subjects with dissections, ruptured aneurysms, or symptomatic aneurysms
  • Subjects with prior AAA repair
  • Subjects with medical conditions that would complicate the endovascular procedure or confound results (e.g., Marfan's syndrome, morbid obesity, severe coronary artery disease)
  • Subjects who are pregnant or lactating
  • Subjects participating in other investigational studies
  • Subjects with less than 2 years life expectancy

Treatment and study plan

Treovance Abdominal Aortic Stent-Graft with Navitel Delivery System

Device

Stent-graft implant

Primary outcomes

  1. major morbidity and mortality

    Time frame: 1, 6, 12 months

Secondary outcomes

  1. Device performance

    Time frame: implant, 1, 6, and 12 months

    Rateof delivery/deployment success will be recorded. Rates of endoleak, patency, migration will be documented a 1, 6, 12 months

Sponsors and collaborators

Lead sponsor

Bolton Medical

Industry

Registry information

Official study title

A Phase I Clinical Study of the Safety and Performance of the Treovance Stent-Graft With Navitel Delivery System for Patients With Infrarenal Abdominal Aortic Aneurysms

Important dates

Study start
2011
Primary completion
2013
Study completion
2017
First posted
Apr 4, 2011
Registry last updated
Dec 20, 2017