Methodist Dallas Medical Center
Dallas, Texas, 75203, United States
NCT Number: NCT04566263
This device was designed to assist in the stent-assisted coil embolization of intracranial aneurysms, specifically those that have a wide neck that would not otherwise maintain the coil embolization material within the aneurysm because of the wide opening at the base of the aneurysm. This device was designed to treat aneurysms that are: unruptured, wide-necked, intracranial, saccular aneurysms arising from a parent vessel ≥ 2 mm and ≤ 4.5 mm. Wide-necked was defined as having a neck > 4mm or dome-to-neck ratio < 2.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Dallas, Texas, 75203, United States
This is a prospective study to investigate the efficacy of using stent-assistance for embolization of intracranial aneurysms with a wide neck (defined as > or = to 4mm, or with a dome to neck ratio of 2:1 or less). We plan to investigate successful embolization of intracranial aneurysms defined by angiographic occlusion of greater than or equal to 90% at 6 months. Patients will be followed for a minimum period of 2 years from the date of the procedure, with a planned total duration of 4 years of the study, including follow up time. Participants will be initially assessed and if included, will undergo procedure that includes use of the device. Afterwards, they will be scheduled for regular follow up at 2 weeks for clinical assessment, then again at 3 months for clinical assessment and MRA to investigate the stented region, then again at 6 months for clinical assessment and possible cerebral angiogram vs possible MRA, and then again at 1 year post-procedure, and then again at 2 years post-procedure. Patients may then follow up on an annual basis or every 2-3 years, depending on preference and any residual or recurrent aneurysm. A more specific timeline and treatment course is described below.
Patients will receive cerebral angiography for evaluation of their cerebral vasculature and aneurysm configuration to ensure that the parent vessel diameter is adequate and that the aneurysm is 4mm in size with a wide neck. In these cases, if it is determined that the patient will require additional vascular support in order to adequately embolize the aneurysm then the use of stent-assisted coil embolization may be offered to the patient.
Once enrolled, patients will undergo endovascular stent-assisted coil embolization of the aneurysm, and clinical outcomes will then be assessed. Data will be collected for analysis according to the primary and secondary outcome measures in addition to any deviations from the protocol or safety concerns as well
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The Stryker Neuroform EZ Stent System is a self-expanding nitinol, compliant, open-cell design that can be deployed by a single operator. The Neuroform EZ Stent System is packaged sterile as a single unit with an introducer sheath and a detachable push wire.
Time frame: 6 months
Successful embolization of intracranial aneurysms defined by angiographic occlusion of greater than or equal to 90%
Methodist Health System
Other
Treatment of Intracranial Wide-neck Aneurysms Using Stent-assisted Coil Embolization With the Stryker Neuroform EZ and Neuroform Atlas Stent Systems
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT01541254
Aneurysm, Brain Diseases
Albany, New York, United States
View Trial DetailsNCT01793792
Aneurysm, Brain Diseases
Phoenix, Arizona, United States
View Trial DetailsNCT06989931
Acute Ischemic Stroke, Aneurysm
Zhangzhou, Fujian, China
View Trial DetailsNCT02921711
Aneurysm, Brain Diseases
View Trial Details