Suez Canal University
Ismailia, 41522, Egypt
NCT Number: NCT05387135
a single-blinded, randomized clinical trial, 68 patients divided into 2 groups: active and sham treatment. Afferents of the Auricular branch of vagus nerve are stimulated using a transcutaneous Vagus Nerve Stimulation device (TENS 7000TM). The electrode was placed in the left cymba concha with direct contact on the skin. The stimulation for both groups will last for 30 minutes once a day for 3 days per week for 12 weeks. The amplitude of the output current was between 0.25-2.0 mA as tolerated and 250 µs width at 25 Hz. All participants initially will be evaluated before and after intervention and 3 months after the end of the sessions.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Ismailia, 41522, Egypt
The included study population is 68.
DESCRIPTION OF THE TECHNIQUE
Active treatment:
Afferents of the Auricular branch of vagus nerve were stimulated using a t-VNS device (TENS 7000TM made by Roscoe Medical Inc., will be used. TENS 7000TM device was labeled as nerve stimulator and low-risk medical device (Instruction manual for TENS 7000). The electrode was placed in the left cymba concha with direct contact on the skin after cleaning with an alcohol swab. The stimulation for both groups will last for 30 minutes once a day for 3 days per week for 12 weeks. The amplitude of the output current was between 0.25-2.0 mA as tolerated and 250 µs width at 10 Hz.
Sham procedure:
For sham-t-VNS device was turned 180°, stimulating the outer earlobe which does not contain fibers of the ABVN. A similar protocol as for active stimulation was used.
All participants initially will be evaluated before and after intervention and 3 months after the end of the sessions by the following:
OUTCOME MEASURES AND ASSESSMENT QUESTIONNAIRES
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Afferents of the Auricular branch of vagus nerve (ABVN) were stimulated using a t-VNS device (TENS 7000TM made by Roscoe Medical Inc., will be used. TENS 7000TM device was labeled as nerve stimulator and low-risk medical device (Instruction manual for TENS 7000).
Time frame: 3 months
to describe pain on 0 to 10 scale
Time frame: 3 months
for function and activity assessment
Suez Canal University
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07327190
Arthritis, Joint Diseases
Kütahya, Turkey (Türkiye)
View Trial DetailsNCT04492670
Arthritis, Joint Diseases
Hong Kong
View Trial DetailsNCT04653896
Arthritis, Joint Diseases
The Bronx, New York, United States
View Trial DetailsNCT07717957
Arthritis, Joint Diseases
Kuantan, Pahang, Malaysia
View Trial Details